• BS EN 12845:2015

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    Fixed firefighting systems. Automatic sprinkler systems. Design, installation and maintenance

    Available format(s):  Hardcopy, PDF

    Superseded date:  04-03-2020

    Language(s):  English

    Published date:  29-02-2016

    Publisher:  British Standards Institution

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    Foreword
    Introduction
    1 Scope
    2 Normative references
    3 Terms and definitions
    4 Contract planning and documentation
    5 Extent of sprinkler protection
    6 Classification of occupancies and fire hazards
    7 Hydraulic design criteria
    8 Water supplies
    9 Type of water supply
    10 Pumps
    11 Installation type and size
    12 Spacing and location of sprinklers
    13 Pipe sizing and layout
    14 Sprinkler design characteristics and uses
    15 Valves
    16 Alarms and alarm devices
    17 Pipework
    18 Signs, notices, and information
    19 Commissioning
    20 Maintenance
    21 Third party inspection
    Annex A (normative) - Classification of typical hazards
    Annex B (normative) - Methodology for categorizing
            stored goods
    Annex C (normative) - Alphabetical listing of stored
            products and categories
    Annex D (normative) - Zoning of sprinkler installations
    Annex E (normative) - Special requirements for
            high rise systems
    Annex F (normative) - Additional measures to improve
            system reliability and availability
    Annex G (normative) - Protection of special hazards
    Annex H (normative) - Sprinkler systems monitoring
    Annex I (normative) - Transmission of alarms
    Annex J (informative) - Precautions and procedures
            when a system is not fully operational
    Annex K (informative) - Twenty-five year inspection
    Annex L (informative) - Special technology
    Annex M (informative) - Independent certification body
    Annex N (normative) - Control Mode Specific Application
            Sprinklers: CMSA
    Annex O (informative) - Example of P&ID
    Annex P (normative) - ESFR sprinkler protection
    Bibliography
    National Annex NA (informative) - Guidance and material
                      related to UK practice

    Abstract - (Show below) - (Hide below)

    Describes requirements and gives recommendations for the design, installation and maintenance of fixed fire sprinkler systems in buildings and industrial plant, and particular requirements for sprinkler systems, which are integral to measures for the protection of life.

    General Product Information - (Show below) - (Hide below)

    Committee FSH/18/2
    Development Note Supersedes 97/541589 DC. (10/2004) Supersedes BS 5306-2(1990). (02/2015) 2004 + A2 2009 Edition along with it's corrigendum remains active. (11/2015)
    Document Type Standard
    Publisher British Standards Institution
    Status Superseded
    Superseded By
    Supersedes

    Standards Referenced By This Book - (Show below) - (Hide below)

    PD 6686:2006 Guidance on directives, regulations and standards related to prevention of fire and explosion in the process industries
    12/30258579 DC : 0 BS 5908-1 - FIRE AND EXPLOSION PRECAUTIONS AT PREMISES HANDLING FLAMMABLE GASES, LIQUIDS AND DUSTS - PART 1: CODE OF PRACTICE FOR PRECAUTIONS AGAINST FIRE AND EXPLOSION IN CHEMICAL PLANTS, CHEMICAL STORAGE AND SIMILAR PREMISES
    09/30189450 DC : 0 BS 8519 - CODE OF PRACTICE FOR THE SELECTION AND INSTALLATION OF FIRE-RESISTANT CABLES AND SYSTEMS FOR LIFE SAFETY AND FIRE-FIGHTING APPLICATIONS
    07/30160342 DC : 0 BS 7273-3 - CODE OF PRACTICE FOR THE OPERATION OF FIRE PROTECTION MEASURES - PART 3: ELECTRICAL ACTUATION OF PRE-ACTION WATERMIST AND SPRINKLER SYSTEMS
    BS 9999:2017 Fire safety in the design, management and use of buildings. Code of practice
    BS DD9999(2005) : 2005 CODE OF PRACTICE FOR FIRE SAFETY IN THE DESIGN, CONSTRUCTION AND USE OF BUILDINGS
    14/30295812 DC : 0 BS 8458 - FIXED FIRE PROTECTION SYSTEMS - RESIDENTIAL AND DOMESTIC WATERMIST SYSTEMS - CODE OF PRACTICE FOR DESIGN AND INSTALLATION
    BS 9251:2014 Fire sprinkler systems for domestic and residential occupancies. Code of practice
    BS 5306-0:2011 Fire protection installations and equipment on premises Guide for selection of installed systems and other fire equipment
    BS 9991:2015 Fire safety in the design, management and use of residential buildings. Code of practice
    BS 9999:2008 Code of practice for fire safety in the design, management and use of buildings
    BS 5839-1:2017 Fire detection and fire alarm systems for buildings Code of practice for design, installation, commissioning and maintenance of systems in non-domestic premises
    BS DD8489-1(2011) : 2011 FIXED FIRE PROTECTION SYSTEMS - INDUSTRIAL AND COMMERCIAL WATERMIST SYSTEMS - PART 1: CODE OF PRACTICE FOR DESIGN AND INSTALLATION
    11/30189447 DC : 0 BS 6266 - FIRE PROTECTION FOR ELECTRONIC EQUIPMENT INSTALLATIONS - CODE OF PRACTICE
    12/30258581 DC : 0 BS 5908-2 - FIRE AND EXPLOSION PRECAUTIONS AT PREMISES HANDLING FLAMMABLE GASES, LIQUIDS AND DUSTS - PART 2: GUIDE TO APPLICABLE STANDARDS AND REGULATIONS
    BS 8591:2014 Remote centres receiving signals from alarm systems. Code of practice
    ISO/TR 19814:2017 Information and documentation Collections management for archives and libraries
    BS 9251:2005 Sprinkler systems for residential and domestic occupancies. Code of practice
    BS 5502-23:2004 Buildings and structures for agriculture Fire precautions. Code of practice
    BS 5588-5:2004 Fire precautions in the design, construction and use of buildings Access and facilities for fire-fighting
    BS 6266:2011 Fire protection for electronic equipment installations. Code of practice
    BS 7273-3:2008 Code of practice for the operation of fire protection measures Electrical actuation of pre-action watermist and sprinkler systems
    BS 5306-1:2006 Code of practice for fire extinguishing installations and equipment on premises Hose reels and foam inlets
    BS 9991:2011 Fire safety in the design, management and use of residential buildings. Code of practice
    15/30301829 DC : 0 BS 9991 - FIRE SAFETY IN THE DESIGN, MANAGEMENT AND USE OF RESIDENTIAL BUILDINGS - CODE OF PRACTICE
    PD 5454:2012 Guide for the storage and exhibition of archival materials
    11/30203947 DC : 0 BS 9991 - FIRE SAFETY IN THE DESIGN, MANAGEMENT AND USE OF RESIDENTIAL BUILDINGS - CODE OF PRACTICE
    PD ISO/TR 19814:2017 Information and documentation. Collections management for archives and libraries
    BS 5839-1:2013 Fire detection and fire alarm systems for buildings Code of practice for design, installation, commissioning and maintenance of systems in non-domestic premises
    BS PAS 95(2011) : 2011 HYPOXIC AIR FIRE PREVENTION SYSTEMS - SPECIFICATION
    BS 7346-5:2005 Components for smoke and heat control systems Functional recommendations and calculation methods for smoke and heat exhaust ventilation systems, employing time-dependent design fires. Code of practice
    BS 5908-2:2012 Fire and explosion precautions at premises handling flammable gases, liquids and dusts Guide to applicable standards and regulations
    16/30314117 DC : 0 BS 9999 - FIRE SAFETY IN THE DESIGN, MANAGEMENT AND USE OF BUILDINGS - CODE OF PRACTICE
    14/30280481 DC : 0 BS 9251 - FIRE SPRINKLER SYSTEMS FOR DOMESTIC AND RESIDENTIAL OCCUPANCIES - CODE OF PRACTICE
    14/30295814 DC : 0 BS 8489-1 - FIXED FIRE PROTECTION SYSTEMS - INDUSTRIAL AND COMMERCIAL WATERMIST SYSTEMS - PART 1: CODE OF PRACTICE FOR DESIGN AND INSTALLATION
    09/30182748 DC : 0 BS 5306-0 - FIRE PROTECTION INSTALLATIONS AND EQUIPMENT ON PREMISES - PART 0: GUIDE FOR THE SELECTION OF INSTALLED SYSTEMS AND OTHER FIRE EQUIPMENT
    BS 8489-1:2016 Fixed fire protection systems. Industrial and commercial watermist systems Code of practice for design and installation
    BS 5588-12:2004 Fire precautions in the design, construction and use of buildings Managing fire safety
    BS 8458:2015 Fixed fire protection systems. Residential and domestic watermist systems. Code of practice for design and installation

    Standards Referencing This Book - (Show below) - (Hide below)

    EN 50342-2:2007/A1:2014 LEAD-ACID STARTER BATTERIES - PART 2: DIMENSIONS OF BATTERIES AND MARKING OF TERMINALS
    EN 60623:2017 Secondary cells and batteries containing alkaline or other non-acid electrolytes - Vented nickel-cadmium prismatic rechargeable single cells
    EN 1057:2006+A1:2010 Copper and copper alloys - Seamless, round copper tubes for water and gas in sanitary and heating applications
    ISO 9606-1:2012 Qualification testing of welders — Fusion welding — Part 1: Steels
    EN 60947-1:2007/A2:2014 LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 1: GENERAL RULES (IEC 60947-1:2007/A2:2014)
    EN 12259-2:1999/A2:2005 FIXED FIREFIGHTING SYSTEMS - COMPONENTS FOR SPRINKLER AND WATER SPRAY SYSTEMS - PART 2: WET ALARM VALVE ASSEMBLIES
    EN 12259-5:2002 Fixed firefighting systems - Components for sprinkler and water spray systems - Part 5: Water flow detectors
    EN ISO 3677:2016 Filler metal for soldering and brazing - Designation (ISO 3677:2016)
    EN ISO 17769-1:2012 Liquid pumps and installation - General terms, definitions, quantities, letter symbols and units - Part 1: Liquid pumps (ISO 17769-1:2012)
    ISO 3677:2016 Filler metal for soldering and brazing — Designation
    EN ISO 9001:2015 Quality management systems - Requirements (ISO 9001:2015)
    ISO 17769-1:2012 Liquid pumps and installation — General terms, definitions, quantities, letter symbols and units — Part 1: Liquid pumps
    IEC 60529:1989+AMD1:1999+AMD2:2013 CSV Degrees of protection provided by enclosures (IP Code)
    IEC 60947-1:2007+AMD1:2010+AMD2:2014 CSV Low-voltage switchgear and controlgear - Part 1: General rules
    ISO 65:1981 Carbon steel tubes suitable for screwing in accordance with ISO 7-1
    ISO 9001:2015 Quality management systems — Requirements
    EN 12259-3:2000/A2:2005 FIXED FIREFIGHTING SYSTEMS - COMPONENTS FOR SPRINKLER AND WATER SPRAY SYSTEMS - PART 3: DRY ALARM VALVE ASSEMBLIES
    EN 12259-1:1999 + A1:2001/A3:2006 FIXED FIREFIGHTING SYSTEMS - COMPONENTS FOR SPRINKLER AND WATER SPRAY SYSTEMS - PART 1: SPRINKLERS
    EN 60529:1991/AC:2016-12 DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015)
    IEC 60623:2017 Secondary cells and batteries containing alkaline or other non-acid electrolytes - Vented nickel-cadmium prismatic rechargeable single cells
    EN ISO 9606-1:2017 Qualification testing of welders - Fusion welding - Part 1: Steels (ISO 9606-1:2012 including Cor 1:2012 and Cor 2:2013)
    EN 12259-4:2000/A1:2001 Fixed firefighting systems - Components for sprinkler and water spray systems - Part 4: Water motor alarms
    EN 50342-1:2015 Lead-acid starter batteries - Part 1: General requirements and methods of test
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective