• BS EN 50132-2-1:1998

    Withdrawn A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

    Alarm systems. CCTV surveillance systems for use in security applications Black and white cameras

    Available format(s):  Hardcopy, PDF

    Withdrawn date:  01-08-2007

    Language(s):  English

    Published date:  15-04-1998

    Publisher:  British Standards Institution

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    Committees responsible
    Foreword
    Introduction
    1 Scope
    2 Normative references and bibliography
        2.1 Normative references
        2.2 Bibliography
    3 Definitions and abbreviations
        3.1 Definitions
        3.2 Abbreviations
    4 Requirements
        4.1 Requirements
        4.2 Video signal output
        4.3 Automatic gain control (AGC)
        4.4 Gamma correction
        4.5 Sensitivity and signal to noise ratio
        4.6 Limiting resolution
        4.7 Contrast Transfer Function (CTF)
        4.8 Black level
        4.9 Automatic light control (ALC) range
        4.10 Synchronization
        4.11 Geometric distortion
        4.12 Aspect ratio
        4.13 Power supply
        4.14 Electrical safety
        4.15 Camera lens mount
        4.16 Camera mount
        4.17 Electromagnetic compatibility
        4.18 Environmental conditions
    5 Test conditions
        5.1 Introduction
        5.2 Test equipment
        5.3 Laboratory conditions
    6 Performance tests
        6.1 Video signal output
        6.2 Gamma correction
        6.3 Sensitivity
        6.4 Signal to noise ratio
        6.5 Limiting resolution
        6.6 Automatic gain control
        6.7 Contrast transfer function (CTF)
        6.8 Black level
        6.9 Synchronization
        6.10 Geometric distortion
    7 Environmental testing
        7.1 Introduction
        7.2 Selection of severity of tests
        7.3 Dry heat (operational)
        7.4 Dry heat (endurance)
        7.5 Cold (operational)
        7.6 Damp heat, steady state (operational)
        7.7 Damp heat, steady state (endurance)
        7.8 Damp heat, cyclic (operational)
        7.9 Damp heat, cyclic (endurance)
        7.10 Water (endurance)
        7.11 Sulfur dioxide (SO2) corrosion (endurance)
        7.12 Salt mist, cyclic (endurance)
        7.13 Shock (operational)
        7.14 Vibration, sinusoidal (operational)
        7.15 Vibration, sinusoidal (endurance)
        7.16 Dust tightness (endurance)
    8 Documentation
    9 Marking and labelling
    Annexes
    A (informative) Scene illumination in relation to camera
        sensitivity
    B (normative) CCTV test charts

    Abstract - (Show below) - (Hide below)

    Specifies minimum requirements for specifying and testing of black and white CCTV cameras for use in surveillance systems for security and safety applications.

    General Product Information - (Show below) - (Hide below)

    Committee GW/1
    Development Note Supersedes 96/520655 DC. (09/2005)
    Document Type Standard
    Publisher British Standards Institution
    Status Withdrawn
    Supersedes

    Standards Referenced By This Book - (Show below) - (Hide below)

    09/30181219 DC : 0 BS 8418 - INSTALLATION AND REMOTE MONITORING OF DETECTOR-ACTIVATED CCTV SYSTEMS - CODE OF PRACTICE
    BS 8418:2003 Installation and remote monitoring of detector activated CCTV systems. Code of practice

    Standards Referencing This Book - (Show below) - (Hide below)

    IEC 60068-2-18:2017 Environmental testing - Part 2-18: Tests - Test R and guidance: Water
    IEC 60068-1:2013 Environmental testing - Part 1: General and guidance
    IEC 60068-2-27:2008 Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock
    EN 60065:2014/AC:2017-01 AUDIO, VIDEO AND SIMILAR ELECTRONIC APPARATUS - SAFETY REQUIREMENTS (IEC 60065:2014/COR2:2016)
    EN 60950:2000/corrigendum:2002 SAFETY OF INFORMATION TECHNOLOGY EQUIPMENT
    PREN 50130-5 : DRAFT 2010 ALARM SYSTEMS - PART 5: ENVIRONMENTAL TEST METHODS
    IEC 60068-2-3:1969 Basic environmental testing procedures - Part 2-3: Tests - Test Ca: Damp heat, steady state
    IEC 60529:1989+AMD1:1999+AMD2:2013 CSV Degrees of protection provided by enclosures (IP Code)
    IEC 60068-2-2:2007 Environmental testing - Part 2-2: Tests - Test B: Dry heat
    IEC 60068-2-42:2003 Environmental testing - Part 2-42: Tests - Test Kc: Sulphur dioxide test for contacts and connections
    IEC 60068-2-1:2007 Environmental testing - Part 2-1: Tests - Test A: Cold
    EN 50130-4:2011/A1:2014 ALARM SYSTEMS - PART 4: ELECTROMAGNETIC COMPATIBILITY - PRODUCT FAMILY STANDARD: IMMUNITY REQUIREMENTS FOR COMPONENTS OF FIRE, INTRUDER, HOLD UP, CCTV, ACCESS CONTROL AND SOCIAL ALARM SYSTEMS
    IEC 60068-2-52:2017 Environmental testing - Part 2-52: Tests - Test Kb: Salt mist, cyclic (sodium chloride solution)
    EN 50132-7:2012 Alarm systems - CCTV surveillance systems for use in security applications - Part 7: Application guidelines
    IEC 60068-2-30:2005 Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle)
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective