• BS EN 60332-3-24:2009

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    Tests on electric and optical fibre cables under fire conditions Test for vertical flame spread of vertically-mounted bunched wires or cables. Category C

    Available format(s):  Hardcopy, PDF

    Superseded date:  24-10-2018

    Language(s):  English

    Published date:  31-01-2010

    Publisher:  British Standards Institution

    Add To Cart

    Scope - (Show below) - (Hide below)

    The series of International Standards covered by Parts 3-10, 3-21, 3-22, 3-23, 3-24 and 3-25 of IEC 60332 specifies methods of test for the assessment of vertical flame spread of vertically-mounted bunched wires or cables, electrical or optical, under defined conditions.

    NOTE For the purpose of this standard, the term ‘electric wire or cable’ covers all insulated metallic conductor cables used for the conveyance of energy or signals.

    The test is intended for type approval testing. The requirements for the selection of cables for testing are given in annex A. The flame spread is measured as the extent of damage of the cable sample. This procedure may be used to demonstrate the cable’s ability to limit flame spread.

    This part of IEC 60332 covers category C and relates to cables installed on the test ladder to achieve a nominal total volume of non-metallic material of 1,5 l per metre of test sample. The flame application time is 20 min. The method of mounting uses the front of the standard ladder. The category is intended for general use where low volumes of non-metallic material are required to be evaluated.

    A recommended performance requirement is given in annex B.

    General Product Information - (Show below) - (Hide below)

    Committee GEL/20/18
    Development Note Supersedes BS EN 50266-2-4 and 09/30198621 DC. (01/2010)
    Document Type Standard
    Publisher British Standards Institution
    Status Superseded
    Superseded By
    Supersedes

    Standards Referenced By This Book - (Show below) - (Hide below)

    11/30214073 DC : 0 BS 7870-4.10 - LV AND MV POLYMERIC INSULATED CABLES FOR USE BY DISTRIBUTION AND GENERATION UTILITIES - PART 4: SPECIFICATION FOR DISTRIBUTION CABLES WITH EXTRUDED INSULATION FOR RATED VOLTAGES OF 11 KV AND 33 KV - SECTION 4.10: SINGLE-CORE 11 KV AND 33 KV CABLES
    11/30214071 DC : 0 BS 7870-3.50 - LV AND MV POLYMERIC INSULATED CABLES FOR USE BY DISTRIBUTION AND GENERATION UTILITIES - PART 3: SPECIFICATION FOR DISTRIBUTION CABLES OF RATED VOLTAGE 0.6/1 KV - SECTION 3.50: XLPE INSULATED, COPPER WIRE WAVEFORM OR HELICAL CONCENTRIC CABLES WITH SOLID ALUMINIUM CONDUCTORS, HAVING LOW EMISSION OF SMOKE AND CORROSIVE GASES WHEN AFFECTED BY FIRE
    BS 7870-4.10(2011) : 2011 LV AND MV POLYMERIC INSULATED CABLES FOR USE BY DISTRIBUTION AND GENERATION UTILITIES - PART 4: SPECIFICATION FOR DISTRIBUTION CABLES WITH EXTRUDED INSULATION OF RATED VOLTAGES OF 11 KV TO 33 KV - SECTION 4.10: SINGLE-CORE 11 KV TO 33 KV CABLES (IMPLEMENTATION OF HD 620)
    BS 7846:2015 Electric cables. Thermosetting insulated, armoured, fire-resistant cables of rated voltage 600/1 000 V for fixed installations, having low emission of smoke and corrosive gases when affected by fire. Specification
    BS 7870-4.20(2011) : 2011 LV AND MV POLYMERIC INSULATED CABLES FOR USE BY DISTRIBUTION AND GENERATION UTILITIES - PART 4: SPECIFICATION FOR DISTRIBUTION CABLES WITH EXTRUDED INSULATION FOR RATED VOLTAGES OF 11 KV TO 33 KV - SECTION 4.20: THREE-CORE 11 KV CABLES (IMPLEMENTATION OF HD 620)
    11/30214061 DC : 0 BS 7870-3.12 - LV AND MV POLYMERIC INSULATED CABLES FOR USE BY DISTRIBUTION AND GENERATION UTILITIES - PART 3: SPECIFICATION FOR DISTRIBUTION CABLES OF RATED VOLTAGE 0.6/1 KV - SECTION 3.12: XLPE INSULATED COMBINED NEUTRAL AND EARTH COPPER WIRE CONCENTRIC CABLES WITH COPPER OR ALUMINIUM CONDUCTORS, HAVING LOW EMISSION OF SMOKE AND CORROSIVE GASES WHEN AFFECTED BY FIRE
    12/30244462 DC : 0 BS 8573 - ELECTRIC CABLES - THERMOSETTING INSULATED, NON-ARMOURED CABLES WITH A VOLTAGE OF 600/1000 V, FOR FIXED INSTALLATIONS, HAVING LOW EMISSIONS OF SMOKE AND CORROSIVE WHEN AFFECTED BY FIRE
    BS 7870-3.12:2011 LV and MV polymeric insulated cables for use by distribution and generation utilities Specification for distribution cables of rated voltage 0.6/1 kV. XLPE insulated combined neutral and earth copper wire concentric cables with copper or aluminium conductors, having low emission of smoke and corrosive gases when affected by fire
    BS 8492(2016) : 2016 TELECOMMUNICATIONS EQUIPMENT AND TELECOMMUNICATIONS CABLING - CODE OF PRACTICE FOR FIRE PERFORMANCE AND PROTECTION
    BS 6724:2016 Electric cables. Thermosetting insulated, armoured cables of rated voltages of 600/1 000 V and 1 900/3 300 V for fixed installations, having low emission of smoke and corrosive gases when affected by fire. Specification
    BS 7870-3.50:2011 LV and MV polymeric insulated cables for use by distribution and generation utilities Specification for distribution cables of rated voltage 0.6/1 kV. XLPE insulated, copper wire waveform or helical concentric cables with solid aluminium conductors, having low emission of smoke and corrosive gases when affected by fire
    15/30301742 DC : 0 BS 7846 - ELECTRIC CABLES - THERMOSETTING INSULATED, ARMOURED, FIRE-RESISTANT CABLES OF RATED VOLTAGE 600/1000 V FOR FIXED INSTALLATIONS, HAVING LOW EMISSION OF SMOKE AND CORROSIVE GASES WHEN AFFECTED BY FIRE - REQUIREMENTS AND TEST METHODS
    BS 7211:2012 Electric cables. Thermosetting insulated and thermoplastic sheathed cables for voltages up to and including 450/750 V for electric power and lighting and having low emission of smoke and corrosive gases when affected by fire
    12/30248745 DC : 0 BS 7211 - ELECTRIC CABLES - THERMOSETTING INSULATED, NON-ARMOURED CABLES FOR VOLTA GES UP TO AND INCLUDING 450/750 V, FOR ELECTRIC POWER, LIGHTING AND INTERNAL WIRING, AND HAVING LOW EMISSION OF SMOKE AND CORROSIVE GASES WHEN AFFECTED BY FIRE
    11/30214077 DC : 0 BS 7870-4.20 - LV AND MV POLYMERIC INSULATED CABLES FOR USE BY DISTRIBUTION AND GENERATION UTILITIES - PART 4: SPECIFICATION FOR DISTRIBUTION CABLES WITH EXTRUDED INSULATION FOR RATED VOLTAGES OF 11 KV AND 33 KV - SECTION 4.20: THREE-CORE 11 KV CABLES
    11/30214065 DC : 0 BS 7870-3.22 - LV AND MV POLYMERIC INSULATED CABLES FOR USE BY DISTRIBUTION AND GENERATION UTILITIES - PART 3: SPECIFICATION FOR DISTRIBUTION CABLES OF RATED VOLTAGE 0.6/1 KV - SECTION 3.22: XLPE INSULATED SPLIT CONCENTRIC CABLES WITH COPPER OR ALUMINIUM CONDUCTORS, HAVING LOW EMISSION OF SMOKE AND CORROSIVE GASES WHEN AFFECTED BY FIRE
    15/30301443 DC : 0 BS 6724 - ELECTRIC CABLES - THERMOSETTING INSULATED, ARMOURED CABLES FOR VOLTAGES OF 600/1000 V AND 1 900/3300 V FOR FIXED INSTALLATIONS, HAVING LOW EMISSION OF SMOKE AND CORROSIVE GASES WHEN AFFECTED BY FIRE - SPECIFICATION
    11/30214057 DC : 0 BS 7870-2 - LV AND MV POLYMERIC INSULATED CABLES FOR USE BY DISTRIBUTION AND GENERATION UTILITIES - PART 2: METHODS OF TEST
    BS 8573:2012 Electric cables. Thermosetting insulated, non-armoured cables with a voltage of 600/1 000V, for fixed installations, having low emissions of smoke and corrosive gases when affected by fire
    BS 7870-3.22:2011 LV and MV polymeric insulated cables for use by distribution and generation utilities Specification for distribution cables of rated voltage 0.6/1 kV. XLPE insulated split concentric cables with copper or aluminium conductors, having low emission of smoke and corrosive gases when affected by fire

    Standards Referencing This Book - (Show below) - (Hide below)

    IEC 60695-4:2012 Fire hazard testing - Part 4: Terminology concerning fire tests for electrotechnical products
    EN 60811-1-3:1995/A1:2001 INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - COMMON TEST METHODS - PART 1-3: GENERAL APPLICATION - METHODS FOR DETERMINING THE DENSITY - WATER ABSORPTION TESTS - SHRINKAGE TEST
    EN 60332-3-10:2009 Tests on electric and optical fibre cables under fire conditions - Part 3-10: Test for vertical flame spread of vertically-mounted bunched wires or cables - Apparatus
    EN 60695-4:2012 FIRE HAZARD TESTING - PART 4: TERMINOLOGY CONCERNING FIRE TESTS FOR ELECTROTECHNICAL PRODUCTS (IEC 60695-4:2012)
    IEC GUIDE 104:2010 The preparation of safety publications and the use of basic safety publications and group safety publications
    IEC 60811-1-3:1993+AMD1:2001 CSV Common test methods for insulating and sheathing materials of electric and optical cables - Part 1-3: General application -Methods for determining the density - Water absorption tests - Shrinkage test
    IEC 60332-3-10:2000+AMD1:2008 CSV Tests on electric and optical fibre cables under fire conditions - Part 3-10: Test for vertical flame spread of vertically-mounted bunched wires or cables - Apparatus
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications