• BS EN 60603-7-5:2010

    Current The latest, up-to-date edition.

    Connectors for electronic equipment Detail specification for 8-way, shielded, free and fixed connectors, for data transmissions with frequencies up to 250 MHz

    Available format(s):  Hardcopy, PDF

    Language(s):  English

    Published date:  31-08-2010

    Publisher:  British Standards Institution

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    FOREWORD
    INTRODUCTION
    1 General
    2 IEC type designation
    3 Common features and isometric view
    4 Cable terminations and internal connections - fixed
      and free connectors
    5 Gauges
    6 Characteristics
    7 Tests and test schedule
    Annex A (normative) - Gauging continuity procedure
    Annex B (normative) - Locking-device mechanical operation
    Annex C (normative) - Test Plug requirements
    Annex D (normative) - General requirements for the
            measurement set-up
    Annex E (normative) - Insertion loss
    Annex F (normative) - Return loss
    Annex G (normative) - Near end cross talk (NEXT)
    Annex H (normative) - Far end cross talk (FEXT)
    Annex I (normative) - Transfer impedance
    Annex J (normative) - Transverse Conversion Loss (TCL)
            and Transverse Conversion Transfer Loss (TCTL)
    Annex K (normative) - Termination of balun
    Annex L (normative) - Gauge requirements
    Annex ZA (normative) - Normative references to international
             publications with their corresponding European
             publications

    Abstract - (Show below) - (Hide below)

    Defines mechanical and environmental requirements, and electrical transmission requirements for frequencies up to 250 MHz.

    Scope - (Show below) - (Hide below)

    This part of IEC 60603-7 covers IEC 60603-7-5 connectors, and specifies mechanical and environmental requirements, and electrical transmission requirements for frequencies up to 250 MHz. These connectors are typically used as category 6 connectors in class E cabling systems specified in ISO/IEC 11801:2002.

    These connectors are intermateable, interoperable, and backward compatible with other IEC 60603-7 series connectors. While the definition of interoperable is being discussed within IEC, “interoperable?? in this standard means the following: The fixed and the free connector are capable of interconnecting with any IEC 60603-7 series connector, and that when it is interconnected, it fully meets all requirements of the lower frequency IEC 60603-7 series standard.

    NOTE Transmission performance categories: in this part of IEC 60603-7, the term “category??, when used in reference to transmission performance, refers to those categories defined by ISO/IEC 11801:2002.

    General Product Information - (Show below) - (Hide below)

    Committee EPL/48
    Development Note Supersedes 09/30201561 DC. (01/2010)
    Document Type Standard
    Publisher British Standards Institution
    Status Current
    Supersedes

    Standards Referencing This Book - (Show below) - (Hide below)

    IEC 61076-1:2006 Connectors for electronic equipment - Product requirements - Part 1: Generic specification
    IEC 60068-1:2013 Environmental testing - Part 1: General and guidance
    EN 60512-1-100:2012 Connectors for electronic equipment - Tests and measurements - Part 1-100: General - Applicable publications
    EN ISO 1302 : 2002 GEOMETRICAL PRODUCT SPECIFICATIONS (GPS) - INDICATION OF SURFACE TEXTURE IN TECHNICAL PRODUCT DOCUMENTATION (ISO 1302:2002)
    EN 60068-1:2014 Environmental testing - Part 1: General and guidance
    ISO/IEC 11801:2002 Information technology Generic cabling for customer premises
    EN 61076-1:2006 Connectors for electronic equipment - Product requirements - Part 1: Generic specification
    IEC 60068-2-38:2009 Environmental testing - Part 2-38: Tests - Test Z/AD: Composite temperature/humidity cyclic test
    ISO 1302:2002 Geometrical Product Specifications (GPS) Indication of surface texture in technical product documentation
    EN 60068-2-38:2009 Environmental testing - Part 2-38: Tests - Test Z/AD: Composite temperature/humidity cyclic test
    IEC 60512-1-100:2012 Connectors for electronic equipment - Tests and measurements - Part 1-100: General - Applicable publications
    EN 60512-27-100:2012 Connectors for electronic equipment - Tests and measurements - Part 27-100: Signal integrity tests up to 500 MHz on IEC 60603-7 series connectors - Tests 27a to 27g
    EN 60664-1:2007 Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests
    EN 60603-1:1998 Connectors for frequencies below 3 MHz for use with printed boards - Part 1: Generic specification - General requirements and guide for the preparation of detail specifications, with assessed quality
    EN 50289-1-14:2004 Communication cables - Specifications for test methods - Part 1-14: Electrical test methods - Coupling attenuation or screening attenuation of connecting hardware
    IEC 60664-1:2007 Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests
    IEC 60050-581:2008 International Electrotechnical Vocabulary (IEV) - Part 581: Electromechanical components for electronic equipment
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective