• BS EN 60794-2-41:2008

    Current The latest, up-to-date edition.

    Optical fibre cables Indoor cables. Product specification for simplex and duplex buffered A4 fibres

    Available format(s): 

    Language(s): 

    Published date:  31-01-2009

    Publisher:  British Standards Institution

    Sorry this product is not available in your region.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    1 Scope
    2 Normative references
    3 Construction
      3.1 General
      3.2 Optical fibres
      3.3 Buffer
      3.4 Strength and anti-buckling members
      3.5 Ripcord
      3.6 Sheath
      3.7 Marking
      3.8 Identification
      3.9 Examples of constructions
    4 Dimensions
    5 Tests
      5.1 General
      5.2 Dimensions
      5.3 Mechanical requirements
          5.3.1 General
          5.3.2 Tensile performance
          5.3.3 Crush
          5.3.4 Impact
          5.3.5 Bend
          5.3.6 Repeated bending
          5.3.7 Bend at low temperature
          5.3.8 Flexing
          5.3.9 Torsion
          5.3.10 Kink
      5.4 Environmental requirements
          5.4.1 Mechanical environmental requirement
          5.4.2 Transmission environmental requirements
      5.5 Transmission requirements
      5.6 Fire performance
    Annex A (informative) - Blank detail specification
    Bibliography
    Annex ZA (normative) - Normative references to
                           international publications
                           with their corresponding
                           European publications

    Abstract - (Show below) - (Hide below)

    Describes simplex and duplex buffered A4a through A4g fibres for indoor use.

    Scope - (Show below) - (Hide below)

    IEC 60794-2-41:2008 covers simplex and duplex buffered A4a through A4g fibres for indoor use. These may be cut into short lengths, which can be used in patchcord cable assemblies. The requirements of sectional specification IEC 60794-2 are applicable to cables covered by this standard. Keywords: A4a through A4g fibres, patchcord cable assemblies

    This publication is to be read in conjunction with IEC 60794-1-1:2011, IEC 60794-1-2:2013 and IEC 60794-2:2002.

    General Product Information - (Show below) - (Hide below)

    Committee GEL/86/1
    Development Note Supersedes 05/30139166 DC. (02/2009)
    Document Type Standard
    Publisher British Standards Institution
    Status Current
    Supersedes

    Standards Referencing This Book - (Show below) - (Hide below)

    EN 60793-1-46:2002 Optical fibres - Part 1-46: Measurement methods and test procedures - Monitoring of changes in optical transmittance
    IEC 60721-1:1990+AMD1:1992+AMD2:1995 CSV Classification of environmental conditions - Part 1: Environmental parameters and their severities
    IEC 60654-4:1987 Operating conditions for industrial-process measurement and control equipment. Part 4: Corrosive and erosive influences
    EN 60793-1-21:2002 Optical fibres - Part 1-21: Measurement methods and test procedures - Coating geometry
    EN 60793-1-20:2014/AC:2016-03 OPTICAL FIBRES - PART 1-20: MEASUREMENT METHODS AND TEST PROCEDURES - FIBRE GEOMETRY (IEC 60793-1-20:2014/COR1:2016)
    EN 60794-2:2017 Optical fibre cables - Part 2: Indoor cables - Sectional specification
    IEC 60793-1-41:2010 Optical fibres - Part 1-41: Measurement methods and test procedures - Bandwidth
    IEC 60189-1:2007 Low-frequency cables and wires with PVC insulation and PVC sheath - Part 1: General test and measuring methods
    IEC 61000-6-2:2016 Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity standard for industrial environments
    IEC 60793-1-52:2014 Optical fibres - Part 1-52: Measurement methods and test procedures - Change of temperature tests
    IEC TR 62222:2012 Fire performance of communication cables installed in buildings
    ISO/IEC 24702:2006 Information technology Generic cabling Industrial premises
    IEC 60793-1-50:2014 Optical fibres - Part 1-50: Measurement methods and test procedures - Damp heat (steady state) tests
    IEC 60794-1-2:2017 Optical fibre cables - Part 1-2: Generic specification - Basic optical cable test procedures - General guidance
    EN 60794-1-1:2016 Optical fibre cables - Part 1-1: Generic specification - General
    EN 60793-2-40:2016 Optical fibres - Part 2-40: Product specifications - Sectional specification for category A4 multimode fibres
    IEC 60793-2-40:2015 Optical fibres - Part 2-40: Product specifications - Sectional specification for category A4 multimode fibres
    EN 61326:1997/A3:2003
    EN 60654-4:1997 Operating conditions for industrial-process measurement and control equipment - Part 4: Corrosive and erosive influences
    IEC 60794-1-1:2015 Optical fibre cables - Part 1-1: Generic specification - General
    EN 60793-1-40:2003 Optical fibres - Part 1-40: Measurement methods and test procedures - Attenuation
    IEC 60793-1-51:2014 Optical fibres - Part 1-51: Measurement methods and test procedures - Dry heat (steady state) tests
    EN 60793-1-50:2015 Optical fibres - Part 1-50: Measurement methods and test procedures - Damp heat (steady state) tests
    IEC 61918:2013 Industrial communication networks - Installation of communication networks in industrial premises
    IEC 60793-1-46:2001 Optical fibres - Part 1-46: Measurement methods and test procedures - Monitoring of changes in optical transmittance
    IEC 60793-1-40:2001 Optical fibres - Part 1-40: Measurement methods and test procedures - Attenuation
    EN 61000-6-2:2005/corrigendum:2005 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-2: GENERIC STANDARDS - IMMUNITY FOR INDUSTRIAL ENVIRONMENTS (IEC 61000-6-2:2005)
    IEC 60794-2-40:2008 Optical fibre cables - Part 2-40: Indoor optical fibre cables - Family specification for A4 fibre cables
    IEC 60793-1-21:2001 Optical fibres - Part 1-21: Measurement methods and test procedures - Coating geometry
    EN 60793-1-52:2014 Optical fibres - Part 1-52: Measurement methods and test procedures - Change of temperature tests
    EN 60793-1-51:2014 Optical fibres - Part 1-51: Measurement methods and test procedures - Dry heat (steady state) tests
    EN 60794-1-2:2017/AC:2017-07 OPTICAL FIBRE CABLES - PART 1-2: GENERIC SPECIFICATION - BASIC OPTICAL CABLE TEST PROCEDURES - GENERAL GUIDANCE (IEC 60794-1-2:2017)
    EN 60793-1-41:2010 Optical fibres - Part 1-41: Measurement methods and test procedures - Bandwidth
    IEC 60721-3-3:1994+AMD1:1995+AMD2:1996 CSV Classification of environmental conditions - Part 3-3: Classification of groups of environmental parameters and their severities - Stationary use at weatherprotected locations
    IEC 60794-2:2017 Optical fibre cables - Part 2: Indoor cables - Sectional specification
    EN 61918:2013/AC:2014 INDUSTRIAL COMMUNICATION NETWORKS - INSTALLATION OF COMMUNICATION NETWORKS IN INDUSTRIAL PREMISES (IEC 61918:2013, MODIFIED)
    IEC 60793-1-20:2014 Optical fibres - Part 1-20: Measurement methods and test procedures - Fibre geometry
    EN 60721-1:1995/A2:1995 CLASSIFICATION OF ENVIRONMENTAL CONDITIONS - PART 1: ENVIRONMENTAL PARAMETERS AND THEIR SEVERITIES
    IEC 61000-6-2 : 3.0:2016 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-2: GENERIC STANDARDS - IMMUNITY STANDARD FOR INDUSTRIAL ENVIRONMENTS
    EN 60794-2-40:2008 Optical fibre cables - Part 2-40: Indoor optical fibre cables - Family specification for A4 fibre cables
    EN 60721-3-3 : 95 AMD 2 97 CLASSIFICATION OF ENVIRONMENTAL CONDITIONS - CLASSIFICATION OF GROUPS OF ENVIRONMENTAL PARAMETERS AND THEIR SEVERITIES - STATIONARY USE AT WEATHER-PROTECTED LOCATIONS
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective