• BS EN ISO 18777:2009

    Current The latest, up-to-date edition.

    Transportable liquid oxygen systems for medical use. Particular requirements

    Available format(s):  Hardcopy, PDF

    Language(s):  English

    Published date:  31-07-2009

    Publisher:  British Standards Institution

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    Foreword
    Introduction
    1 Scope
    2 Normative references
    3 Terms and definitions
    4 General requirements and general requirements
        for tests
    5 Classification
    6 Identification, marking and documents
    7 Power input
    8 Basic safety categories
    9 Removable protective means
    10 Environmental conditions
    11 Not used
    12 Not used
    13 General
    14 Requirements related to classification
    15 Limitation of voltage and/or energy
    16 Enclosures and protective covers
    17 Separation
    18 Protective earthing, functional earthing and
        potential equalization
    19 Continuous leakage currents and patient auxiliary
        currents
    20 Dielectric strength
    21 Mechanical strength
    22 Moving parts
    23 Surfaces, corners and edges
    24 Stability in normal use
    25 Expelled parts
    26 Vibration and noise
    27 Pneumatic and hydraulic power
    28 Suspended masses
    29 X-Radiation
    30 Alpha, beta, gamma, neutron radiation and other
        particle radiation
    31 Microwave radiation
    32 Light radiation (including lasers)
    33 Infrared radiation
    34 Ultraviolet energy
    35 Acoustical energy (including ultrasonics)
    36 Electromagnetic compatibility
    37 Locations and basic requirements
    38 Marking and accompanying documents
    39 Common requirements for category AP and category
        APG equipment
    40 Requirements and tests for category AP equipment,
        parts and components thereof
    41 Requirements and tests for category APG equipment,
        parts and components thereof
    42 Excessive temperatures
    43 Fire prevention
    44 Overflow, spillage, leakage, humidity, ingress of
        liquids, cleaning, sterilization, disinfection and
        compatibility
    45 Pressure vessels and parts subject to pressure
    46 Human errors
    47 Electrostatic charges
    48 Biocompatibility
    49 Interruption of the power supply
    50 Accuracy of operating data
    51 Protection against hazardous output
    52 Abnormal operation and fault conditions
    53 Environmental tests
    54 General
    55 Enclosures and covers
    56 Components and general assembly
    57 Mains parts, components and layout
    58 Protective earthing - Terminals and connections
    59 Construction and layout
    101 Additional requirements
    Annexes
    Annex AA (informative) - Rationale
    Annex BB (informative) - Environmental aspects
    Annex CC (informative) - Index of defined terms
    Bibliography
    Annex ZA (informative) - Relationship between this European
             Standard and the Essential Requirements of EU
             Directive 93/42/EEC

    Abstract - (Show below) - (Hide below)

    Provides requirements for the safety and essential performance of transportable liquid oxygen systems which are used as a supply source for oxygen therapy.

    Scope - (Show below) - (Hide below)

    IEC60601-1:1988, Clause1, applies except as follows:

    Amendments (add at end of 1.1):

    1.1 This International Standard specifies requirements for the safety and essential performance of transportable liquid oxygen systems which are used as a supply source for oxygen therapy. These devices usually consist of a portable unit to be carried by or with the patient whilst in use and the vessel used to refill the portable unit. These devices are mostly used in home care applications and in health care facilities/institutions. These devices are often used without professional supervision.

    Liquid oxygen vessels used as a supply source for oxygen pipeline systems are excluded from this International Standard.

    The requirements of this International Standard which replace or modify the requirements of IEC60601-1:1998 and its Amendments 1 (1991) and 2 (1995) are intended to take precedence over the corresponding general requirements.

    1.4 Addition:

    NOTE Planning and design of products complying with this Internatinal Standard can have environmental impact during the product life cycle. Environmental aspects are addressed in Annex BB. Additional aspects of environmental impact are addressed in ISO14971.

    General Product Information - (Show below) - (Hide below)

    Committee CH/121/5
    Development Note Supersedes 03/114562 DC. (04/2005) To be read in conjunction with BS EN 60601-1. Supersedes 08/30192553 DC. (07/2009)
    Document Type Standard
    Publisher British Standards Institution
    Status Current
    Supersedes

    Standards Referencing This Book - (Show below) - (Hide below)

    ISO 18779:2005 Medical devices for conserving oxygen and oxygen mixtures Particular requirements
    IEC 60601-1:2005+AMD1:2012 CSV Medical electrical equipment - Part 1: General requirements for basic safety and essential performance
    EN 1251-2:2000/AC:2006 CRYOGENIC VESSELS - TRANSPORTABLE VACUUM INSULATED VESSELS OF NOT MORE THAN 1000 LITRES VOLUME - PART 2: DESIGN, FABRICATION, INSPECTION AND TESTING
    ISO 15001:2010 Anaesthetic and respiratory equipment Compatibility with oxygen
    IEC 60601-1-6:2010+AMD1:2013 CSV Medical electrical equipment - Part 1-6: General requirements for basic safety and essential performance - Collateral standard: Usability
    IEC 60601-1-2:2014 Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests
    EN 1041:2008+A1:2013 Information supplied by the manufacturer of medical devices
    IEC 60529:1989+AMD1:1999+AMD2:2013 CSV Degrees of protection provided by enclosures (IP Code)
    NFPA 53M : 1990 FIRE HAZARDS IN OXYGEN-ENRICHED ATMOSPHERES
    ISO 7000:2014 Graphical symbols for use on equipment Registered symbols
    ISO 4135:2001 Anaesthetic and respiratory equipment Vocabulary
    EN 1251-3:2000 Cryogenic vessels - Transportable vacuum insulated vessels of not more than 1000 litres volume - Part 3: Operational requirements
    EN 980:2008 Symbols for use in the labelling of medical devices
    EN 13544-2:2002+A1:2009 Respiratory therapy equipment - Part 2: Tubing and connectors
    EN 1251-1:2000 Cryogenic vessels - Transportable vacuum insulated vessels of not more than 1000 litres volume - Part 1: Fundamental requirements
    EN 60601-1-8:2007/A11:2017 MEDICAL ELECTRICAL EQUIPMENT - PART 1-8: GENERAL REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE - COLLATERAL STANDARD: GENERAL REQUIREMENTS, TESTS AND GUIDANCE FOR ALARM SYSTEMS IN MEDICAL ELECTRICAL EQUIPMENT AND MEDICAL ELECTRICAL SYSTEMS (IEC 60601-1-8:2006/A1:2012)
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective