• CSA C22.2 No. 61058.1 : 2009 : INC : UPD 1 : 2013

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    SWITCHES FOR APPLIANCES - PART 1: GENERAL REQUIREMENTS

    Available format(s):  Hardcopy, PDF

    Superseded date:  24-09-2020

    Language(s):  English, French

    Published date:  01-01-2014

    Publisher:  Canadian Standards Association

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    Preface
    NATIONAL DIFFERENCES
    FOREWORD
    1 Scope
    2 Normative references
    3 Definitions
    4 General requirements
    5 General notes on tests
    6 Rating
    7 Classification
    8 Marking and documentation
    9 Protection against electric shock
    10 Provision for earthing
    11 TERMINALS and TERMINATIONS
    12 Construction
    13 Mechanism
    14 Protection against solid foreign objects, ingress of
       water and humid conditions
    15 Insulation resistance and dielectric strength
    16 Heating
    17 Endurance
    18 Mechanical strength
    19 Screws, current-carrying parts and connections
    20 CLEARANCES, CREEPAGE DISTANCES, SOLID INSULATION and
       COATINGS of rigid PRINTED BOARD ASSEMBLIES
    21 Fire hazard
    22 Resistance to rusting
    23 Abnormal OPERATION and fault conditions for ELECTRONIC
       SWITCHES
    24 Components for electronic switches
    25 EMC requirements
    Annex A (normative) - Measurement of CLEARANCES and CREEPAGE
            DISTANCES
    Annex B (informative) - Diagram for the dimensioning of
            CLEARANCES and CREEPAGE DISTANCES
    Annex C (Void)
    Annex D (normative) - Proof tracking test
    Annex E (Void)
    Annex F (informative) - Switch application guide
    Annex G (Void)
    Annex H (informative) - FLAT QUICK-CONNECT TERMINATIONS, method
            for selection of FEMALE CONNECTORS
    Annex J (Void)
    Annex K (normative) - Relation between rated IMPULSE WITHSTAND
            VOLTAGE, RATED VOLTAGE and OVERVOLTAGE CATEGORY
    Annex L (normative) - POLLUTION DEGREE
    Annex M (normative) - Impulse voltage test
    Annex N (normative) - Altitude correction factors
    Annex P (normative) - Types of COATINGS for rigid PRINTED BOARD
            ASSEMBLIES
    Annex Q (normative) - Measuring the INSULATION DISTANCE of a
            coated PRINTED BOARD with type A COATING
    Annex R (normative) - Routine tests
    Annex S (informative) - Sampling tests
    Annex T (informative) - Switch families
    Annex U (normative) - Dimensions of TABS forming part of a SWITCH
    Annex V (informative) - Requirements and tests for resistance
            to abnormal heat for unattended appliances
    Bibliography
    Annex DVA (normative) - Horsepower rated switches
    Annex DVB (normative) - Tungsten-filament-lamp and synthetic loads
    Annex DVC (normative) - Television switches
    Annex DVD (informative) - Clarifications

    Abstract - (Show below) - (Hide below)

    Pertains to switches (mechanical or electronic) for appliances actuated by hand, by foot or by other human activity, to operate or control electrical appliances and other equipment for household or similar purposes with a RATED VOLTAGE not exceeding 480 V and a RATED CURRENT not exceeding 63 A.

    General Product Information - (Show below) - (Hide below)

    Development Note Also numbered as UL 61058-1. (10/2007)
    Document Type Standard
    Product Note Reconfirmed EN
    Publisher Canadian Standards Association
    Status Superseded
    Superseded By
    Supersedes

    Standards Referencing This Book - (Show below) - (Hide below)

    IEC 61000-4-8 : 2.0 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-8: TESTING AND MEASUREMENT TECHNIQUES - POWER FREQUENCY MAGNETIC FIELD IMMUNITY TEST
    CISPR 14-1:2016 Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission
    IEC 60112:2003+AMD1:2009 CSV Method for the determination of the proof and the comparative tracking indices of solid insulating materials
    IEC 60038:2009 IEC standard voltages
    IEC 60738-1:2006+AMD1:2009 CSV Thermistors - Directly heated positive temperature coefficient -Part 1: Generic specification
    IEC 60730-2-9:2015 RLV Automatic electrical controls - Part 2-9: Particular requirements for temperature sensing controls
    IEC 60228:2004 Conductors of insulated cables
    IEC 60384-14:2013+AMD1:2016 CSV Fixed capacitors for use in electronic equipment - Part 14: Sectional specification - Fixed capacitors for electromagnetic interference suppression and connection to the supply mains
    ASTM D 3638 : 2012 : REDLINE Standard Test Method for Comparative Tracking Index of Electrical Insulating Materials
    IEC 61000-4-4 : 3.0EN+(REDLINE+VERSION) ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-4: TESTING AND MEASUREMENT TECHNIQUES - ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST
    IEC 61000-4-1:2006 Electromagnetic compatibility (EMC) - Part 4-1: Testing and measurement techniques - Overview of IEC 61000-4 series
    IEC 60068-2-20:2008 Environmental testing - Part 2-20: Tests - Test T: Test methods for solderability and resistance to soldering heat of devices with leads
    IEC 60998-2-3:2002 Connecting devices for low-voltage circuits for household and similar purposes - Part 2-3: Particular requirements for connecting devices as separate entities with insulation-piercing clamping units
    IEC 61058-2-1:2010 Switches for appliances - Part 2-1: Particular requirements for cord switches
    IEC 60695-4:2012 Fire hazard testing - Part 4: Terminology concerning fire tests for electrotechnical products
    IEC 60050-411:1996 International Electrotechnical Vocabulary (IEV) - Part 411: Rotating machinery
    IEC 60050-151:2001 International Electrotechnical Vocabulary (IEV) - Part 151: Electrical and magnetic devices
    IEC 61000-4-11:2004+AMD1:2017 CSV Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests
    IEC 60050-441:1984 International Electrotechnical Vocabulary (IEV) - Part 441: Switchgear, controlgear and fuses
    IEC 61210:2010 Connecting devices - Flat quick-connect terminations for electrical copper conductors - Safety requirements
    IEC 60893-1:2004 Insulating materials - Industrial rigid laminated sheets based on thermosetting resins for electrical purposes - Part 1: Definitions, designations and general requirements
    IEC 61000-4-8:2009 Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test
    CISPR 15:2013+AMD1:2015 CSV Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment
    IEC 61000-4-4:2012 RLV Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
    IEC 60695-2-11:2014 Fire hazard testing - Part 2-11: Glowing/hot-wire based test methods - Glow-wire flammability test method for end-products (GWEPT)
    IEC 60269-1:2006+AMD1:2009+AMD2:2014 CSV Low-voltage fuses - Part 1: General requirements
    ISO 2081:2008 Metallic and other inorganic coatings Electroplated coatings of zinc with supplementary treatments on iron or steel
    IEC 60695-2-13:2010+AMD1:2014 CSV Fire hazard testing - Part 2-13: Glowing/hot-wire based test methods- Glow-wire ignition temperature (GWIT) test method for materials
    IEC 61058-2-5:2010 Switches for appliances - Part 2-5: Particular requirements for change-over selectors
    IEC 61000-4-6 : 4.0 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-6: TESTING AND MEASUREMENT TECHNIQUES - IMMUNITY TO CONDUCTED DISTURBANCES, INDUCED BY RADIO-FREQUENCY FIELDS
    IEC 61000-4-6:2013 Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields
    IEC 60127-2:2014 Miniature fuses - Part 2: Cartridge fuse-links
    IEC 60085:2007 Electrical insulation - Thermal evaluation and designation
    ISO 1456:2009 Metallic and other inorganic coatings — Electrodeposited coatings of nickel, nickel plus chromium, copper plus nickel and of copper plus nickel plus chromium
    IEC 60695-2-12:2010+AMD1:2014 CSV Fire hazard testing - Part 2-12: Glowing/hot-wire based test methods- Glow-wire flammability index (GWFI) test method for materials
    IEC 60707:1999 Flammability of solid non-metallic materials when exposed to flame sources - List of test methods
    IEC 60529:1989+AMD1:1999+AMD2:2013 CSV Degrees of protection provided by enclosures (IP Code)
    IEC 61058-2-4:1995+AMD1:2003 CSV Switches for appliances - Part 2-4: Particular requirements for independently mounted switches
    IEC 60691:2015 Thermal-links - Requirements and application guide
    IEC 61000-4-2:2008 Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
    IEC 60695-11-10:2013 Fire hazard testing - Part 11-10: Test flames - 50 W horizontal and vertical flame test methods
    IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test
    ISO 2093:1986 Electroplated coatings of tin — Specification and test methods
    IEC 60669-1:2017 Switches for household and similar fixed-electrical installations - Part 1: General requirements
    IEC 61000-3-3:2013 RLV Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection
    IEC 60034-1:2017 Rotating electrical machines - Part 1: Rating and performance
    ISO 4046:1978 Paper, board, pulp and related terms — Vocabulary
    IEC 60050-826:2004 International Electrotechnical Vocabulary (IEV) - Part 826: Electrical installations
    IEC 61000-3-3 : 3.0EN+(REDLINE+VERSION) ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 3-3: LIMITS - LIMITATION OF VOLTAGE CHANGES, VOLTAGE FLUCTUATIONS AND FLICKER IN PUBLIC LOW-VOLTAGE SUPPLY SYSTEMS, FOR EQUIPMENT WITH RATED CURRENT <= 16 A PER PHASE AND NOT SUBJECT TO CONDITIONAL CONNECTION
    IEC 60068-2-75:2014 Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests
    IEC 60664-3:2016 Insulation coordination for equipment within low-voltage systems - Part 3: Use of coating, potting or moulding for protection against pollution
    IEC 60695-10-2:2014 Fire hazard testing - Part 10-2: Abnormal heat - Ball pressure test method
    IEC 60060-1:2010 High-voltage test techniques - Part 1: General definitions and test requirements
    IEC 61140:2016 Protection against electric shock - Common aspects for installation and equipment
    IEC 61032:1997 Protection of persons and equipment by enclosures - Probes for verification
    IEC 60695-2-10:2013 Fire hazard testing - Part 2-10: Glowing/hot-wire based test methods - Glow-wire apparatus and common test procedure
    IEC 60664-1:2007 Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests
    IEC 60617-2:1996 Graphical symbols for diagrams - Partie 2: Symbol elements, qualifying symbols and other symbols having general application
    IEC 61000-3-2 : 4.0 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 3-2: LIMITS - LIMITS FOR HARMONIC CURRENT EMISSIONS (EQUIPMENT INPUT CURRENT <= 16 A PER PHASE)
    IEC 60269-3-1:2004 Low-voltage fuses - Part 3-1: Supplementary requirements for fuses for use by unskilled persons (fuses mainly for household and similar applications) - Sections I to IV: Examples of types of standardized fuses
    IEC 60730-1:2013+AMD1:2015 CSV Automatic electrical controls - Part 1: General requirements
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective