• CSA CEI/IEC 61000.4.7 : 2003(R2007)

    Withdrawn A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

    ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-7: TESTING AND MEASUREMENT TECHNIQUES - GENERAL GUIDE ON HARMONICS AND INTERHARMONICS MEASUREMENTS AND INSTRUMENTATION, FOR POWER SUPPLY SYSTEMS AND EQUIPMENT CONNECTED THERETO

    Available format(s): 

    Withdrawn date:  23-07-2021

    Language(s): 

    Published date:  12-01-2013

    Publisher:  Canadian Standards Association

    Sorry this product is not available in your region.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    FOREWORD
    INTRODUCTION
    1 Scope
    2 Normative references
    3 Definitions, symbols and indices
       3.1 Definitions related to frequency analysis
       3.2 Definitions related to harmonics
       3.3 Definitions related to distortion factors
       3.4 Definitions related to interharmonics
       3.5 Notations
           3.5.1 Symbols and abbreviations
           3.5.2 Indices
    4 General concepts and common requirements for all
       types of instrumentation
       4.1 Characteristics of the signal to be measured
       4.2 Accuracy classes of instrumentation
       4.3 Types of measurement
       4.4 General structure of the instrument
           4.4.1 Main instrument
           4.4.2 Post-processing parts
    5 Harmonic measurements
       5.1 Current input circuit
       5.2 Voltage input circuit
       5.3 Accuracy requirements
       5.4 Measurement set-up for emission assessment
       5.5 Assessment of harmonic emissions
           5.5.1 Grouping and smoothing
           5.5.2 Compliance with emission limits
       5.6 Assessment of voltage harmonic subgroups
    6 Other analysis principles
    7 Transitional period
    8 General
    Annex A (informative) Measurement of interharmonics
    Annex B (informative) Measurements above the harmonic
            frequency range up to 9 kHz
    Annex C (informative) Technical considerations for
            grouping method
    Bibliography
    Figures and Tables

    Abstract - (Show below) - (Hide below)

    Specifies instrumentation intended for measuring spectral components in the frequency range up to 9 kHz which are superimposed on the fundamental of the power supply systems at 50 Hz and 60 Hz.

    General Product Information - (Show below) - (Hide below)

    Development Note Supersedes CSA C22.2.0.16. (01/2008) Renumbered as CSA IEC 61000-4-7. (08/2013)
    Document Type Standard
    Publisher Canadian Standards Association
    Status Withdrawn
    Superseded By
    Supersedes

    Standards Referenced By This Book - (Show below) - (Hide below)

    CSA C61000.4.1:2009 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-1: TESTING AND MEASUREMENT TECHNIQUES - OVERVIEW OF IEC 61000-4 SERIES
    CSA C61000.2.2 : 2004 : R2014 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 2-2: ENVIRONMENT - COMPATIBILITY LEVELS FOR LOW-FREQUENCY CONDUCTED DISTURBANCES AND SIGNALLING IN PUBLIC LOW-VOLTAGE POWER SUPPLY SYSTEMS
    CSA C61000.4.1 : 2009 : R2014 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-1: TESTING AND MEASUREMENT TECHNIQUES - OVERVIEW OF IEC 61000-4 SERIES
    CSA C860 : 2011 : INC : UPD 2 : 2012 PERFORMANCE OF INTERNALLY LIGHTED EXIT SIGNS
    CSA C61000.2.12 : 2004 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 2-12: ENVIRONMENT - COMPATIBILITY LEVELS FOR LOW-FREQUENCY CONDUCTED DISTURBANCES AND SIGNALLING IN PUBLIC MEDIUM-VOLTAGE POWER SUPPLY SYSTEMS
    CSA C61000.2.12 : 2004 : R2014 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 2-12: ENVIRONMENT - COMPATIBILITY LEVELS FOR LOW-FREQUENCY CONDUCTED DISTURBANCES AND SIGNALLING IN PUBLIC MEDIUM-VOLTAGE POWER SUPPLY SYSTEMS
    CAN/CSA-C61000-2-2-04 (R2018) Electromagnetic Compatibility (EMC) - Part 2-2: Environment - Compatibility Levels for Low-Frequency Conducted Disturbances and Signalling in Public Low-Voltage Power Supply Systems (Adopted CEI/IEC 61000-2-2:2002, second edition, 2002-03, with Canadian deviations) | Compatibilité électromagnétique (CEM) - Partie 2-2: Environnement - Niveaux de compatibilité pour les perturbations conduites à basse fréquence et la transmission des signaux sur les réseaux publics d\'alimentation basse tension (norme CEI/IEC 61000-2-2:2002 adoptée, deuxième édition, 2002-03, avec exigences propres au Canada)
    CSA C860 : 2011 : INC : UPD 1 : 2011 PERFORMANCE OF INTERNALLY LIGHTED EXIT SIGNS
    CSA C61000.2.2 : 2004 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 2-2: ENVIRONMENT - COMPATIBILITY LEVELS FOR LOW-FREQUENCY CONDUCTED DISTURBANCES AND SIGNALLING IN PUBLIC LOW-VOLTAGE POWER SUPPLY SYSTEMS
    CSA C860 : 2011 : R2016 PERFORMANCE OF INTERNALLY LIGHTED EXIT SIGNS
    CSA C860 : 2011 PERFORMANCE OF INTERNALLY LIGHTED EXIT SIGNS

    Standards Referencing This Book - (Show below) - (Hide below)

    IEC 61000-4-30 : 3.0EN+(REDLINE+VERSION) ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-30: TESTING AND MEASUREMENT TECHNIQUES - POWER QUALITY MEASUREMENT METHODS
    IEC 61000-3-11 : 2.0 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 3-11: LIMITS - LIMITATION OF VOLTAGE CHANGES, VOLTAGE FLUCTUATIONS AND FLICKER IN PUBLIC LOW-VOLTAGE SUPPLY SYSTEMS - EQUIPMENT WITH RATED CURRENT <= 75 A AND SUBJECT TO CONDITIONAL CONNECTION
    IEC 61967-1:2002 Integrated circuits - Measurement of electromagnetic emissions, 150 kHz to 1 GHz - Part 1: General conditions and definitions
    IEC 61000-3-8:1997 Electromagnetic compatibility (EMC) - Part 3: Limits - Section 8: Signalling on low-voltage electrical installations - Emission levels, frequency bands and electromagnetic disturbance levels
    IEC 61000-3-3 : 3.0EN+(REDLINE+VERSION) ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 3-3: LIMITS - LIMITATION OF VOLTAGE CHANGES, VOLTAGE FLUCTUATIONS AND FLICKER IN PUBLIC LOW-VOLTAGE SUPPLY SYSTEMS, FOR EQUIPMENT WITH RATED CURRENT <= 16 A PER PHASE AND NOT SUBJECT TO CONDITIONAL CONNECTION
    IEC 61010-1:2010+AMD1:2016 CSV Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 1: General requirements
    CISPR 16-1:1999+AMD1:2002 CSV Specification for radio disturbance and immunity measuring apparatus and methods - Part 1: Radio disturbance and immunity measuring apparatus
    IEC 61000-3-2 : 4.0 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 3-2: LIMITS - LIMITS FOR HARMONIC CURRENT EMISSIONS (EQUIPMENT INPUT CURRENT <= 16 A PER PHASE)
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective