• CSA CEI/IEC 62304:14 (R2019)

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    Medical device software - Software life cycle processes (Adopted CEI/IEC 62304:2006, first edition, 2006-05) | Logiciels de dispositifs médicaux - Processus du cycle de vie du logiciel (norme CEI/IEC 62304:2006 adoptée, première édition, 2006-05)

    Available format(s):  Hardcopy, PDF

    Superseded date:  19-08-2021

    Language(s):  English - French

    Published date:  01-01-2014

    Publisher:  Canadian Standards Association

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    FOREWORD
    INTRODUCTION
    1 Scope
    2 Normative references
    3 Terms and definitions
    4 General requirements
    5 Software development PROCESS
    6 Software maintenance PROCESS
    7 Software RISK MANAGEMENT PROCESS
    8 Software configuration management PROCESS
    9 Software problem resolution PROCESS
    Annex A (informative) - Rationale for the requirements of
            this standard
    Annex B (informative) - Guidance on the provisions of this
            standard
    Annex C (informative) - Relationship to other standards
    Annex D (informative) - Implementation
    Bibliography
    Index of defined terms

    Abstract - (Show below) - (Hide below)

    CSA Preface This is the first edition of CAN/CSA-CEI/IEC 62304, Medical device software - Software life cycle processes, which is an adoption without modification of the identically titled CEI/IEC (Commission Électrotechnique Internationale/International Electrotechnical Commission) Standard 62304 (first edition, 2006-05). For brevity, this Standard will be referred to as \"CAN/CSA-CEI/IEC 62304\" throughout. Scope 1.1 * Purpose This standard defines the life cycle requirements for MEDICAL DEVICE SOFTWARE. The set of PROCESSES, ACTIVITIES, and TASKS described in this standard establishes a common framework for MEDICAL DEVICE SOFTWARE life cycle PROCESSES. 1.2 * Field of application This standard applies to the development and maintenance of MEDICAL DEVICE SOFTWARE. This standard applies to the development and maintenance of MEDICAL DEVICE SOFTWARE when software is itself a MEDICAL DEVICE or when software is an embedded or integral part of the final MEDICAL DEVICE. This standard does not cover validation and final release of the MEDICAL DEVICE, even when the MEDICAL DEVICE consists entirely of software. 1.3 Relationship to other standards This MEDICAL DEVICE SOFTWARE life cycle standard is to be used together with other appropriate standards when developing a MEDICAL DEVICE. Annex C shows the relationship between this standard and other relevant standards. 1.4 Compliance Compliance with this standard is defined as implementing all of the PROCESSES, ACTIVITIES, and TASKS identified in this standard in accordance with the software safety class. NOTE The software safety classes assigned to each requirement are identified in the normative text following the requirement. Compliance is determined by inspection of all documentation required by this standard including the RISK MANAGEMENT FILE, and assessment of the PROCESSES, ACTIVITIES and TASKS required for the software safety class. See Annex D. NOTE 1 This assessment could be carried out by internal or external audit. NOTE 2 Although the specified PROCESSES, ACTIVITIES, and TASKS are performed, flexibility exists in the methods of implementing these PROCESSES and performing these ACTIVITIES and TASKS. NOTE 3 Where any requirements contain \"as appropriate\" and were not performed, documentation for the justification is necessary for this assessment. NOTE 4 The term \"conformance\" is used in ISO/IEC 12207 where the term \"compliance\" is used in this standard. ---------------------------------------------------------------------------------- Préface CSA Ce document constitue la première édition de la CAN/CSA-CEI/IEC 62304, Logiciels de dispositifs médicaux - Processus du cycle de vie du logiciel. Il s\'agit de l\'adoption, sans modification, de la norme CEI/IEC (Commission Électrotechnique Internationale/International Electrotechnical Commission) 62304 (première édition, 2006-05) qui porte le même titre. Par souci de brièveté, tout au long de ce document, il sera appelé «CAN/CSA-CEI/IEC 62304». Domaine d\'application 1.1 *Objet La présente norme définit les exigences du cycle de vie des LOGICIELS DE DISPOSITIFS MÉDICAUX. L\'ensemble des PROCESSUS, ACTIVITÉS et TÂCHES décrit dans la présente norme constitue un cadre commun pour les PROCESSUS du cycle de vie des LOGICIELS DE DISPOSITIFS MÉDICAUX. 1.2 * Domaine d\'application La présente norme s\'applique au développement et à la maintenance des LOGICIELS DE DISPOSITIFS MÉDICAUX. La présente norme s\'applique au développement et à la maintenance des LOGICIELS DE DISPOSITIFS MÉDICAUX lorsque le logiciel est un DISPOSITIF MÉDICAL ou lorsque le logiciel est incorporé ou fait partie intégrante du DISPOSITIF MÉDICAL final. La présente norme ne couvre pas la validation et la mise sur le marché du DISPOSITIF MÉDICAL, même lorsque le DISPOSITIF MÉDICAL est intégralement constitué du logiciel. 1.3 Relations avec d\'autres normes La présente norme couvrant le cycle de vie des LOGICIELS DE DISPOSITIFS MÉDICAUX doit être utilisée conjointement à d\'autres normes pertinentes pour le développement d\'un DISPOSITIF MÉDICAL. L\'Annexe C présente les relations existant entre la présente norme et d\'autres normes pertinentes. 1.4 Conformité La conformité à la présente norme est définie comme la mise en oeuvre de tous les PROCESSUS, ACTIVITÉS et TÂCHES identifiés dans la présente norme en fonction de la classe de sécurité. NOTE Les classes de sécurité du logiciel assignées à chaque exigence sont identifiées dans le texte normatif suivant l\'exigence. La conformité est déterminée par inspection de toute documentation exigée par la présente norme y compris le DOSSIER DE GESTION DES RISQUES et l\'évaluation des PROCESSUS, ACTIVITÉS et TÂCHES requis pour la classe de SÉCURITÉ du logiciel. Voir l\'Annexe D. NOTE 1 Cette évaluation peut être effectuée par audit interne ou externe. NOTE 2 Même lorsque les PROCESSUS, ACTIVITÉS et TÂCHES sont effectivement réalisés, il existe une certaine flexibilité dans les méthodes de mise en oeuvre de ces PROCESSUS et d\'exécution de ces ACTIVITÉS et TÂCHEs. NOTE 3 Lorsqu\'une éventuelle exigence comporte la mention «le cas échéant» ou «si nécessaire» et qu\'elle n\'est pas réalisée, une justification écrite est nécessaire pour cette évaluation. NOTE 4 Dans la version anglaise de l\'ISO/CEI 12207 le terme «conformance» est utilisé pour «conformité», alors que dans la version anglaise de la présente norme, on utilise le terme «compliance».

    Scope - (Show below) - (Hide below)

    CSA Preface This is the first edition of CAN/CSA-CEI/IEC 62304, Medical device software - Software life cycle processes, which is an adoption without modification of the identically titled CEI/IEC (Commission Électrotechnique Internationale/International Electrotechnical Commission) Standard 62304 (first edition, 2006-05). For brevity, this Standard will be referred to as \"CAN/CSA-CEI/IEC 62304\" throughout. Scope 1.1 * Purpose This standard defines the life cycle requirements for MEDICAL DEVICE SOFTWARE. The set of PROCESSES, ACTIVITIES, and TASKS described in this standard establishes a common framework for MEDICAL DEVICE SOFTWARE life cycle PROCESSES. 1.2 * Field of application This standard applies to the development and maintenance of MEDICAL DEVICE SOFTWARE. This standard applies to the development and maintenance of MEDICAL DEVICE SOFTWARE when software is itself a MEDICAL DEVICE or when software is an embedded or integral part of the final MEDICAL DEVICE. This standard does not cover validation and final release of the MEDICAL DEVICE, even when the MEDICAL DEVICE consists entirely of software. 1.3 Relationship to other standards This MEDICAL DEVICE SOFTWARE life cycle standard is to be used together with other appropriate standards when developing a MEDICAL DEVICE. Annex C shows the relationship between this standard and other relevant standards. 1.4 Compliance Compliance with this standard is defined as implementing all of the PROCESSES, ACTIVITIES, and TASKS identified in this standard in accordance with the software safety class. NOTE The software safety classes assigned to each requirement are identified in the normative text following the requirement. Compliance is determined by inspection of all documentation required by this standard including the RISK MANAGEMENT FILE, and assessment of the PROCESSES, ACTIVITIES and TASKS required for the software safety class. See Annex D. NOTE 1 This assessment could be carried out by internal or external audit. NOTE 2 Although the specified PROCESSES, ACTIVITIES, and TASKS are performed, flexibility exists in the methods of implementing these PROCESSES and performing these ACTIVITIES and TASKS. NOTE 3 Where any requirements contain \"as appropriate\" and were not performed, documentation for the justification is necessary for this assessment. NOTE 4 The term \"conformance\" is used in ISO/IEC 12207 where the term \"compliance\" is used in this standard. ---------------------------------------------------------------------------------- Préface CSA Ce document constitue la première édition de la CAN/CSA-CEI/IEC 62304, Logiciels de dispositifs médicaux - Processus du cycle de vie du logiciel. Il s\'agit de l\'adoption, sans modification, de la norme CEI/IEC (Commission Électrotechnique Internationale/International Electrotechnical Commission) 62304 (première édition, 2006-05) qui porte le même titre. Par souci de brièveté, tout au long de ce document, il sera appelé «CAN/CSA-CEI/IEC 62304». Domaine d\'application 1.1 *Objet La présente norme définit les exigences du cycle de vie des LOGICIELS DE DISPOSITIFS MÉDICAUX. L\'ensemble des PROCESSUS, ACTIVITÉS et TÂCHES décrit dans la présente norme constitue un cadre commun pour les PROCESSUS du cycle de vie des LOGICIELS DE DISPOSITIFS MÉDICAUX. 1.2 * Domaine d\'application La présente norme s\'applique au développement et à la maintenance des LOGICIELS DE DISPOSITIFS MÉDICAUX. La présente norme s\'applique au développement et à la maintenance des LOGICIELS DE DISPOSITIFS MÉDICAUX lorsque le logiciel est un DISPOSITIF MÉDICAL ou lorsque le logiciel est incorporé ou fait partie intégrante du DISPOSITIF MÉDICAL final. La présente norme ne couvre pas la validation et la mise sur le marché du DISPOSITIF MÉDICAL, même lorsque le DISPOSITIF MÉDICAL est intégralement constitué du logiciel. 1.3 Relations avec d\'autres normes La présente norme couvrant le cycle de vie des LOGICIELS DE DISPOSITIFS MÉDICAUX doit être utilisée conjointement à d\'autres normes pertinentes pour le développement d\'un DISPOSITIF MÉDICAL. L\'Annexe C présente les relations existant entre la présente norme et d\'autres normes pertinentes. 1.4 Conformité La conformité à la présente norme est définie comme la mise en oeuvre de tous les PROCESSUS, ACTIVITÉS et TÂCHES identifiés dans la présente norme en fonction de la classe de sécurité. NOTE Les classes de sécurité du logiciel assignées à chaque exigence sont identifiées dans le texte normatif suivant l\'exigence. La conformité est déterminée par inspection de toute documentation exigée par la présente norme y compris le DOSSIER DE GESTION DES RISQUES et l\'évaluation des PROCESSUS, ACTIVITÉS et TÂCHES requis pour la classe de SÉCURITÉ du logiciel. Voir l\'Annexe D. NOTE 1 Cette évaluation peut être effectuée par audit interne ou externe. NOTE 2 Même lorsque les PROCESSUS, ACTIVITÉS et TÂCHES sont effectivement réalisés, il existe une certaine flexibilité dans les méthodes de mise en oeuvre de ces PROCESSUS et d\'exécution de ces ACTIVITÉS et TÂCHEs. NOTE 3 Lorsqu\'une éventuelle exigence comporte la mention «le cas échéant» ou «si nécessaire» et qu\'elle n\'est pas réalisée, une justification écrite est nécessaire pour cette évaluation. NOTE 4 Dans la version anglaise de l\'ISO/CEI 12207 le terme «conformance» est utilisé pour «conformité», alors que dans la version anglaise de la présente norme, on utilise le terme «compliance».

    General Product Information - (Show below) - (Hide below)

    Development Note Amendment 1 is available separately, see CSA CEI/IEC 62304A. (02/2018)
    Document Type Standard
    Publisher Canadian Standards Association
    Status Superseded
    Superseded By

    Standards Referencing This Book - (Show below) - (Hide below)

    ISO/IEC 15504-5:2012 Information technology Process assessment Part 5: An exemplar software life cycle process assessment model
    IEEE 610.12-1990 IEEE Standard Glossary of Software Engineering Terminology
    ISO/IEC 25010:2011 Systems and software engineering — Systems and software Quality Requirements and Evaluation (SQuaRE) — System and software quality models
    IEC 60601-1:2005+AMD1:2012 CSV Medical electrical equipment - Part 1: General requirements for basic safety and essential performance
    ISO/IEC 33001:2015 Information technology Process assessment Concepts and terminology
    IEC 60601-1-6:2010+AMD1:2013 CSV Medical electrical equipment - Part 1-6: General requirements for basic safety and essential performance - Collateral standard: Usability
    ISO/IEC 14764:2006 Software Engineering Software Life Cycle Processes Maintenance
    ISO 13485:2016 Medical devices Quality management systems Requirements for regulatory purposes
    IEC 61508-3:2010 Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 3: Software requirements (see Functional Safety and IEC 61508)
    ISO/IEC Guide 51:2014 Safety aspects Guidelines for their inclusion in standards
    ISO/IEC 12207:2008 Systems and software engineering Software life cycle processes
    ISO 9001:2015 Quality management systems — Requirements
    ISO 9000:2015 Quality management systems — Fundamentals and vocabulary
    ISO/IEC 90003:2014 Software engineering Guidelines for the application of ISO 9001:2008 to computer software
    IEC 61010-1:2010+AMD1:2016 CSV Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 1: General requirements
    IEC 60601-1-4:1996+AMD1:1999 CSV Medical electrical equipment - Part 1-4: General requirements for safety - Collateral Standard: Programmable electrical medical systems
    ISO/IEC 33004:2015 Information technology Process assessment Requirements for process reference, process assessment and maturity models
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective