• DIN EN 50267-2-3 : 1999

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    COMMON TEST METHODS FOR CABLES UNDER FIRE CONDITIONS - TESTS ON GASES EVOLVED DURING COMBUSTION OF MATERIAL FROM CABLES - PART 2-3: PROCEDURES - DETERMINATION OF DEGREE OF ACIDITY OF GASES FOR CABLES BY DETERMINATION OF THE WEIGHTED AVERAGE OF PH AND CONDUCTIVITY

    Available format(s): 

    Superseded date:  01-08-2015

    Language(s): 

    Published date:  12-01-2013

    Publisher:  Verband Deutscher Elektrotechniker

    Sorry this product is not available in your region.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    1 Anwendungsbereich
    2 Normative Verweisungen
    3 Definition
    4 Prüfgerät
    5 Prüfverfahren
      5.1 Grundsätzliches Prinzip
      5.2 Proben und Konditionierung
      5.3 Probestück
      5.4 Verfahren
      5.5 Bestimmung von pH-Wert und Leitfähigkeit
    6 Auswertung
      6.1 Mittelwert
      6.2 Gewichtete Werte
    Anhang A (informativ) Anforderungen an die
             Gebrauchstauglichkeit

    Abstract - (Show below) - (Hide below)

    EN 50267-2-3 legt die Prüfverfahren für die Bestimmung von pH-Wert und Leitfähigkeit von Gasen fest, die bei der Verbrennung von Kabeln, isolierten Leitungen und LWL-Kabeln entstehen; und zwar durch die Bestimmung gewichteter Mittelwerte von pH und Leitfähigkeit der zusammengesetzten Werkstoffe. ANMERKUNG: In den einschlägigen Kabelnormen sollte angegeben sein, welche der Kabelwerkstoffe zu prüfen sind.

    General Product Information - (Show below) - (Hide below)

    Development Note Supersedes DIN VDE 0472-813. (09/2004)
    Document Type Standard
    Publisher Verband Deutscher Elektrotechniker
    Status Superseded
    Superseded By
    Supersedes

    Standards Referenced By This Book - (Show below) - (Hide below)

    VDE 0482-267-2-1 : 1999 COMMON TEST METHODS FOR CABLES UNDER FIRE CONDITIONS - TESTS AN GASES EVOLVED DURING COMBUSTION OF MATERIALS FROM CABLES - PART 2-1: PROCEDURES - DETERMINATION OF THE AMOUNT OF HALOGEN ACID GAS
    DIN EN 50267-2-2 : 1999 COMMON TEST METHODS FOR CABLES UNDER FIRE CONDITIONS - TESTS ON GASES EVOLVED DURING COMBUSTION OF MATERIAL FROM CABLES - PART 2-2: PROCEDURES - DETERMINATION OF DEGREE OF ACIDITY OF GASES FOR MATERIALS BY MEASURING PH AND CONDUCTIVITY
    VDE 0101 : 2000 POWER INSTALLATIONS EXCEEDING 1 KV
    VDE 0482-267-1 : 1999 COMMON TEST METHODS FOR CABLES UNDER FIRE CONDITIONS - TESTS ON GASES EVOLVED DURING COMBUSTION OF MATERIALS FROM CABLES - PART 1: APPARATUS
    DIN EN 50267-2-1 : 1999 COMMON TEST METHODS FOR CABLES UNDER FIRE CONDITIONS - TESTS ON GASES EVOLVED DURING COMBUSTION OF MATERIAL FROM CABLES - PART 2-1: PROCEDURES - DETERMINATION OF THE AMOUNT OF HALOGEN ACID GAS
    VDE 0482-267-2-2 : 1999 COMMON TEST METHODS FOR CABLES UNDER FIRE CONDITIONS - TESTS AN GASES EVOLVED DURING COMBUSTION OF MATERIALS FROM CABLES - PART 2-2: PROCEDURES - DETERMINATION OF DEGREE OF ACIDITY OF GASES FOR MATERIALS BY MEASURING PH AND CONDUCTIVITY

    Standards Referencing This Book - (Show below) - (Hide below)

    IEC 60695-4:2012 Fire hazard testing - Part 4: Terminology concerning fire tests for electrotechnical products
    DIN EN 50267-1 : 1999 COMMON TEST METHODS FOR CABLES UNDER FIRE CONDITIONS - TESTS ON GASES EVOLVED DURING COMBUSTION OF MATERIALS FROM CABLES - PART 1: APPARATUS
    EN 50267-1:1998 Common test methods for cables under fire conditions - Tests on gases evolved during combustion of materials from cables - Part 1: Apparatus
    VDE 0482-267-1 : 1999 COMMON TEST METHODS FOR CABLES UNDER FIRE CONDITIONS - TESTS ON GASES EVOLVED DURING COMBUSTION OF MATERIALS FROM CABLES - PART 1: APPARATUS
    DIN EN 50267-2-2 : 1999 COMMON TEST METHODS FOR CABLES UNDER FIRE CONDITIONS - TESTS ON GASES EVOLVED DURING COMBUSTION OF MATERIAL FROM CABLES - PART 2-2: PROCEDURES - DETERMINATION OF DEGREE OF ACIDITY OF GASES FOR MATERIALS BY MEASURING PH AND CONDUCTIVITY
    VDE 0482-267-2-2 : 1999 COMMON TEST METHODS FOR CABLES UNDER FIRE CONDITIONS - TESTS AN GASES EVOLVED DURING COMBUSTION OF MATERIALS FROM CABLES - PART 2-2: PROCEDURES - DETERMINATION OF DEGREE OF ACIDITY OF GASES FOR MATERIALS BY MEASURING PH AND CONDUCTIVITY
    EN 60695-4:2012 FIRE HAZARD TESTING - PART 4: TERMINOLOGY CONCERNING FIRE TESTS FOR ELECTROTECHNICAL PRODUCTS (IEC 60695-4:2012)
    DIN EN 50267-2-1 : 1999 COMMON TEST METHODS FOR CABLES UNDER FIRE CONDITIONS - TESTS ON GASES EVOLVED DURING COMBUSTION OF MATERIAL FROM CABLES - PART 2-1: PROCEDURES - DETERMINATION OF THE AMOUNT OF HALOGEN ACID GAS
    VDE 0482-267-2-1 : 1999 COMMON TEST METHODS FOR CABLES UNDER FIRE CONDITIONS - TESTS AN GASES EVOLVED DURING COMBUSTION OF MATERIALS FROM CABLES - PART 2-1: PROCEDURES - DETERMINATION OF THE AMOUNT OF HALOGEN ACID GAS
    DIN EN 60695-4 : 2013 FIRE HAZARD TESTING - PART 4: TERMINOLOGY CONCERNING FIRE TESTS FOR ELECTROTECHNICAL PRODUCTS (IEC 60695-4:2012)
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective