IEC 60695-11-20:2015
|
Fire hazard testing - Part 11-20: Test flames - 500 W flame test method |
IEC 61000-4-8 : 2.0
|
ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-8: TESTING AND MEASUREMENT TECHNIQUES - POWER FREQUENCY MAGNETIC FIELD IMMUNITY TEST |
IEC 60112:2003+AMD1:2009 CSV
|
Method for the determination of the proof and the comparative tracking indices of solid insulating materials |
IEC 60038:2009
|
IEC standard voltages |
EN 60068-2-75:2014
|
Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests |
IEC 60738-1:2006+AMD1:2009 CSV
|
Thermistors - Directly heated positive temperature coefficient -Part 1: Generic specification |
IEC 60730:1982
|
Automatic controls for electrical household appliances |
IEC 60730-2-9:2015 RLV
|
Automatic electrical controls - Part 2-9: Particular requirements for temperature sensing controls |
IEC 60228:2004
|
Conductors of insulated cables |
IEC 60127:1974
|
Cartridge fuse-links for miniature fuses |
IEC 61000-4-4 : 3.0EN+(REDLINE+VERSION)
|
ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-4: TESTING AND MEASUREMENT TECHNIQUES - ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST |
EN 60065:2014/AC:2017-01
|
AUDIO, VIDEO AND SIMILAR ELECTRONIC APPARATUS - SAFETY REQUIREMENTS (IEC 60065:2014/COR2:2016) |
IEC 60068-2-20:2008
|
Environmental testing - Part 2-20: Tests - Test T: Test methods for solderability and resistance to soldering heat of devices with leads |
IEC 60998-2-3:2002
|
Connecting devices for low-voltage circuits for household and similar purposes - Part 2-3: Particular requirements for connecting devices as separate entities with insulation-piercing clamping units |
EN 61000-4-11:2004/A1:2017
|
ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-11: TESTING AND MEASUREMENT TECHNIQUES - VOLTAGE DIPS, SHORT INTERRUPTIONS AND VOLTAGE VARIATIONS IMMUNITY TESTS (IEC 61000-4-11:2004/A1:2017) |
EN 60695-10-2:2014
|
Fire hazard testing - Part 10-2: Abnormal heat - Ball pressure test method |
IEC 60050-411:1996
|
International Electrotechnical Vocabulary (IEV) - Part 411: Rotating machinery |
IEC 60050-151:2001
|
International Electrotechnical Vocabulary (IEV) - Part 151: Electrical and magnetic devices |
IEC 61000-4-11:2004+AMD1:2017 CSV
|
Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests |
EN 61000-3-3:2013
|
ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 3-3: LIMITS - LIMITATION OF VOLTAGE CHANGES, VOLTAGE FLUCTUATIONS AND FLICKER IN PUBLIC LOW-VOLTAGE SUPPLY SYSTEMS, FOR EQUIPMENT WITH RATED CURRENT <= 16 A PER PHASE AND NOT SUBJECT TO CONDITIONAL CONNECTION (IEC 61000-3-3:2013) |
EN 60730-2-9:2010
|
Automatic electrical controls for household and similar use - Part 2-9: Particular requirements for temperature sensing controls |
IEC 60050-441:1984
|
International Electrotechnical Vocabulary (IEV) - Part 441: Switchgear, controlgear and fuses |
IEC 61058-1-1:2016
|
Switches for appliances - Part 1-1: Requirements for mechanical switches |
EN 60738-1:2006/A1:2009
|
THERMISTORS - DIRECTLY HEATED POSITIVE TEMPERATURE COEFFICIENT - PART 1: GENERIC SPECIFICATION |
EN 60060-1:2010
|
High-voltage test techniques - Part 1: General definitions and test requirements |
IEC 61210:2010
|
Connecting devices - Flat quick-connect terminations for electrical copper conductors - Safety requirements |
IEC 60893-1:2004
|
Insulating materials - Industrial rigid laminated sheets based on thermosetting resins for electrical purposes - Part 1: Definitions, designations and general requirements |
EN 61058-1-2:2016
|
Switches for appliances - Part 1-2: Requirements for electronic switches |
IEC 61000-4-8:2009
|
Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test |
IEC 61000-4-4:2012 RLV
|
Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test |
EN 60691:2016
|
Thermal-links - Requirements and application guide |
EN 61000-4-2:2009
|
Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test |
IEC 60695-2-11:2014
|
Fire hazard testing - Part 2-11: Glowing/hot-wire based test methods - Glow-wire flammability test method for end-products (GWEPT) |
EN 60127-2:2014
|
Miniature fuses - Part 2: Cartridge fuse-links |
EN 60112 : 2003 AMD 1 2009
|
METHOD FOR THE DETERMINATION OF THE PROOF AND THE COMPARATIVE TRACKING INDICES OF SOLID INSULATING MATERIALS |
EN 61000-4-3 : 2006 AMD 2 2010
|
ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-3: TESTING AND MEASUREMENT TECHNIQUES - RADIATED, RADIO-FREQUENCY, ELECTROMAGNETIC FIELD IMMUNITY TEST |
IEC 60085:2007
|
Electrical insulation - Thermal evaluation and designation |
EN 61058-1-1:2016
|
Switches for appliances - Part 1-1: Requirements for mechanical switches |
EN 61000-4-8:2010
|
Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test |
IEC 60691:2015
|
Thermal-links - Requirements and application guide |
IEC 61000-4-2:2008
|
Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test |
IEC 60695-11-10:2013
|
Fire hazard testing - Part 11-10: Test flames - 50 W horizontal and vertical flame test methods |
IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV
|
Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test |
EN 61032:1998
|
Protection of persons and equipment by enclosures - Probes for verification |
IEC 61000-3-3:2013 RLV
|
Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection |
EN 61000-3-2:2014
|
Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase) |
IEC 60034-1:2017
|
Rotating electrical machines - Part 1: Rating and performance |
EN 61210:2010
|
Connecting devices - Flat quick-connect terminations for electrical copper conductors - Safety requirements |
IEC 60050-826:2004
|
International Electrotechnical Vocabulary (IEV) - Part 826: Electrical installations |
IEC 61000-3-3 : 3.0EN+(REDLINE+VERSION)
|
ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 3-3: LIMITS - LIMITATION OF VOLTAGE CHANGES, VOLTAGE FLUCTUATIONS AND FLICKER IN PUBLIC LOW-VOLTAGE SUPPLY SYSTEMS, FOR EQUIPMENT WITH RATED CURRENT <= 16 A PER PHASE AND NOT SUBJECT TO CONDITIONAL CONNECTION |
IEC 60068-2-75:2014
|
Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests |
IEC 60664-3:2016
|
Insulation coordination for equipment within low-voltage systems - Part 3: Use of coating, potting or moulding for protection against pollution |
EN 61000-4-4:2012
|
ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-4: TESTING AND MEASUREMENT TECHNIQUES - ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST (IEC 61000-4-4:2012) |
IEC 60695-10-2:2014
|
Fire hazard testing - Part 10-2: Abnormal heat - Ball pressure test method |
EN 60529:1991/AC:2016-12
|
DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015) |
IEC 60060-1:2010
|
High-voltage test techniques - Part 1: General definitions and test requirements |
IEC 61140:2016
|
Protection against electric shock - Common aspects for installation and equipment |
IEC 61032:1997
|
Protection of persons and equipment by enclosures - Probes for verification |
IEC 61058-1-2:2016
|
Switches for appliances - Part 1-2: Requirements for electronic switches |
IEC 60664-1:2007
|
Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests |
EN 60664-3:2017
|
Insulation coordination for equipment within low-voltage systems - Part 3: Use of coating, potting or moulding for protection against pollution |
EN 60038 : 2011
|
CENELEC STANDARD VOLTAGES (IEC 60038:2009, MODIFIED) |
EN 55014-1:2017
|
Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission |
EN 60730-1:2016
|
Automatic electrical controls - Part 1: General requirements |
EN 60695-2-11:2014
|
Fire hazard testing - Part 2-11: Glowing/hot-wire based test methods - Glow-wire flammability test method for end-products (GWEPT) (IEC 60695-2-11:2014) |
IEC 61000-3-2 : 4.0
|
ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 3-2: LIMITS - LIMITS FOR HARMONIC CURRENT EMISSIONS (EQUIPMENT INPUT CURRENT <= 16 A PER PHASE) |
IEC 60730-1:2013+AMD1:2015 CSV
|
Automatic electrical controls - Part 1: General requirements |