• EN ISO 80369-1:2010

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    Small bore connectors for liquids and gases in healthcare applications - Part 1: General requirements (ISO 80369-1:2010)

    Available format(s): 

    Superseded date:  17-01-2019

    Language(s): 

    Published date:  15-12-2010

    Publisher:  Comite Europeen de Normalisation

    Pure ENs are not available for sale, please purchase a suitable national adoption

    Sorry this product is not available in your region.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    Foreword
    Introduction
    1 Scope
    2 Normative references
    3 Terms and definitions
    4 Materials used for SMALL-BORE CONNECTORS
    5 Requirements for SMALL-BORE CONNECTORS for specific
      APPLICATIONS
    6 Additional SMALL-BORE CONNECTOR APPLICATIONS
    7 PROCEDURE to assess a proposed new design of SMALL-BORE
      CONNECTOR for inclusion in this series of standards
    Annex A (informative) - Rationale
    Annex B (normative) - Mechanical tests for verifying
            NON-INTERCONNECTABLE characteristics
    Annex C (informative) - APPLICATIONS of SMALL-BORE CONNECTORS
    Annex D (informative) - Reference to the Essential Principles
    Bibliography
    Terminology - Alphabetized index of defined terms
    Annex ZA (informative) - Relationship between this European
             Standard and the Essential Requirements of EU
             Directive 93/42/EEC

    Abstract - (Show below) - (Hide below)

    ISO 80369-1:2010 specifies general requirements for small-bore connectors, which convey liquids or gases in healthcare applications. These small-bore connectors are used in medical devices or accessories intended for use with a patient. ISO 80369-1:2010 also specifies the healthcare fields in which these small-bore connectors are intended to be used.These healthcare fields of use include, but are not limited to, applications for:breathing systems and driving gases, enteral and gastric, urethral and urinary, limb cuff inflation, neuraxial devices, and intravascular or hypodermic. Small-bore connectors as specified in ISO 80369-1:2010 are non-interconnectable with:the cones and sockets of ISO 5356-1:2004 and ISO 5356-2:2006; the temperature sensor connector and mating ports specified in Annex DD of ISO 8185:2007; and the nipples of EN 13544-2:2002. ISO 80369-1:2010 provides the methodology to assess non-interconnectable characteristics of small-bore connectors based on their inherent design and dimensions in order to reduce the risk of misconnections between medical devices or between accessories for different applications and to reduce the risk of misconnections between medical devices with 6 % Luer connectors, and all other non-Luer (6 %) connectors that will be developed under future parts of this series of standards.It does not specify requirements for the medical devices or accessories that use these small-bore connectors. Such requirements are given in particular International Standards for specific medical devices or accessories.

    General Product Information - (Show below) - (Hide below)

    Development Note Supersedes EN 15546-1. (01/2011)
    Document Type Standard
    Publisher Comite Europeen de Normalisation
    Status Superseded
    Superseded By
    Supersedes

    Standards Referenced By This Book - (Show below) - (Hide below)

    UNE-EN ISO 80369-7:2017 Small-bore connectors for liquids and gases in healthcare applications - Part 7: Connectors for intravascular or hypodermic applications (ISO 80369-7:2016, Corrected version 2016-12-01)
    17/30338753 DC : 0 BS ISO 80601-2-79 - MEDICAL ELECTRICAL EQUIPMENT - PART 2-79: PARTICULAR REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE OF VENTILATORY SUPPORT EQUIPMENT FOR VENTILATORY IMPAIRMENT
    CEI EN 80369-5 : 1ED 2017 SMALL-BORE CONNECTORS FOR LIQUIDS AND GASES IN HEALTHCARE APPLICATIONS - PART 5: CONNECTORS FOR LIMB CUFF INFLATION APPLICATIONS
    BS EN ISO 7864:2016 Sterile hypodermic needles for single use. Requirements and test methods
    I.S. EN ISO 7864:2016 STERILE HYPODERMIC NEEDLES FOR SINGLE USE - REQUIREMENTS AND TEST METHODS (ISO/DIS 7864:2014)
    BS EN ISO 80369-7:2017 Small-bore connectors for liquids and gases in healthcare applications Connectors for intravascular or hypodermic applications
    16/30346835 DC : 0 BS ISO 20789 - ANAESTHETIC AND RESPIRATORY EQUIPMENT - PASSIVE HUMIDIFIERS
    UNE-EN 80369-5:2017 Small-bore connectors for liquids and gases in healthcare applications - Part 5: Connectors for limb cuff inflation applications
    DIN EN ISO 80369-7 E : 2017 SMALL-BORE CONNECTORS FOR LIQUIDS AND GASES IN HEALTHCARE APPLICATIONS - PART 7: CONNECTORS FOR INTRAVASCULAR OR HYPODERMIC APPLICATIONS (ISO 80369-7:2016, CORRECTED VERSION 2016-12-01)
    I.S. EN 80369-5:2016 SMALL-BORE CONNECTORS FOR LIQUIDS AND GASES IN HEALTHCARE APPLICATIONS - PART 5: CONNECTORS FOR LIMB CUFF INFLATION APPLICATIONS
    ISO 7864:2016 Sterile hypodermic needles for single use — Requirements and test methods
    DIN EN 80369-5:2017-10 SMALL-BORE CONNECTORS FOR LIQUIDS AND GASES IN HEALTHCARE APPLICATIONS - PART 5: CONNECTORS FOR LIMB CUFF INFLATION APPLICATIONS (IEC 80369-5:2016 + COR.1:2017)
    EN ISO 7864:2016 Sterile hypodermic needles for single use - Requirements and test methods (ISO 7864:2016)
    DIN EN 80369-5 E : 2017 SMALL-BORE CONNECTORS FOR LIQUIDS AND GASES IN HEALTHCARE APPLICATIONS - PART 5: CONNECTORS FOR LIMB CUFF INFLATION APPLICATIONS (IEC 80369-5:2016 + COR.1:2017)
    EN ISO 80369-7:2017 Small-bore connectors for liquids and gases in healthcare applications - Part 7: Connectors for intravascular or hypodermic applications (ISO 80369-7:2016, Corrected version 2016-12-01)
    I.S. EN ISO 80369-7:2017 COR 2017 SMALL-BORE CONNECTORS FOR LIQUIDS AND GASES IN HEALTHCARE APPLICATIONS - PART 7: CONNECTORS FOR INTRAVASCULAR OR HYPODERMIC APPLICATIONS (ISO 80369-7:2016, CORRECTED VERSION 2016-12-01)
    DIN EN ISO 80369-7:2017-10 Small-bore connectors for liquids and gases in healthcare applications - Part 7: Connectors for intravascular or hypodermic applications (ISO 80369-7:2016, Corrected version 2016-12-01)

    Standards Referencing This Book - (Show below) - (Hide below)

    IEC 60601-1:2005+AMD1:2012 CSV Medical electrical equipment - Part 1: General requirements for basic safety and essential performance
    ISO 5356-1:2015 Anaesthetic and respiratory equipment Conical connectors Part 1: Cones and sockets
    ISO 5356-2:2012 Anaesthetic and respiratory equipment — Conical connectors — Part 2: Screw-threaded weight-bearing connectors
    IEC 62366:2007+AMD1:2014 CSV Medical devices - Application of usability engineering to medical devices
    ISO 5359:2014 Anaesthetic and respiratory equipment Low-pressure hose assemblies for use with medical gases
    CR 13825:2000 Luer connectors - A report to CEN chef from the CEN forum task group "Luer fittings"
    ISO 8185:2007 Respiratory tract humidifiers for medical use Particular requirements for respiratory humidification systems
    ISO/TR 16142:2006 Medical devices Guidance on the selection of standards in support of recognized essential principles of safety and performance of medical devices
    ASTM D 790 : 2017 : REDLINE Standard Test Methods for Flexural Properties of Unreinforced and Reinforced Plastics and Electrical Insulating Materials
    ISO 14971:2007 Medical devices Application of risk management to medical devices
    EN 13544-2:2002+A1:2009 Respiratory therapy equipment - Part 2: Tubing and connectors
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective