    1 Scope
    2 Normative references
    3 Definitions
    4 Electromagnetic environment
    5 Disturbing phenomena
    6 Immunity requirements
    7 Testing
    8 Documentation for the purchaser/user
    Annex A (normative) - Method of measurement of immunity
            to radiated magnetic fields, 50 Hz to 10 kHz
    Annex B (normative) - Methods of measurement of common
            mode immunity for balanced signal and control
            ports intended to be connected to cables whose
            total length according to the manufacturer's
            specification may exceed 10 m; 50 Hz to 10 kHz
    Annex C (informative) - Apparatus using infra-red radiation
            for open-air transmission purposes
    Annex D (informative) - Guidance for test houses on immunity
            testing of audio, video, audio-visual and entertainment
            lighting control apparatus for professional use
    Annex E (informative) - Background information about this
            standard
    Annex ZZ (informative) - Coverage of Essential Requirements
             of EC Directives
    Bibliography

    Abstract - (Show below) - (Hide below)

    Pertains to professional audio, video, audio-visual and entertainment lighting control apparatus as defined in 3.6 intended for use in the environments described in Clause 4.

    General Product Information - (Show below) - (Hide below)

    Document Type Standard
    Publisher National Standards Authority of Ireland
    Status Current

    Standards Referencing This Book - (Show below) - (Hide below)

    CISPR 20:2006+AMD1:2013 CSV Sound and television broadcast receivers and associated equipment -Immunity characteristics - Limits and methods of measurement
    IEC 61000-4-4 : 3.0EN+(REDLINE+VERSION) ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-4: TESTING AND MEASUREMENT TECHNIQUES - ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST
    EN 61000-4-11:2004/A1:2017 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-11: TESTING AND MEASUREMENT TECHNIQUES - VOLTAGE DIPS, SHORT INTERRUPTIONS AND VOLTAGE VARIATIONS IMMUNITY TESTS (IEC 61000-4-11:2004/A1:2017)
    IEC 61000-4-11:2004+AMD1:2017 CSV Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests
    EN 61000-4-2:2009 Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
    IEC 61000-4-6 : 4.0 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-6: TESTING AND MEASUREMENT TECHNIQUES - IMMUNITY TO CONDUCTED DISTURBANCES, INDUCED BY RADIO-FREQUENCY FIELDS
    EN 61000-4-3 : 2006 AMD 2 2010 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-3: TESTING AND MEASUREMENT TECHNIQUES - RADIATED, RADIO-FREQUENCY, ELECTROMAGNETIC FIELD IMMUNITY TEST
    EN 55020:2007/A12:2016 SOUND AND TELEVISION BROADCAST RECEIVERS AND ASSOCIATED EQUIPMENT - IMMUNITY CHARACTERISTICS - LIMITS AND METHODS OF MEASUREMENT (CISPR 20:2006)
    EN 61000-6-2:2005/corrigendum:2005 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-2: GENERIC STANDARDS - IMMUNITY FOR INDUSTRIAL ENVIRONMENTS (IEC 61000-6-2:2005)
    IEC 61000-4-2:2008 Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
    IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test
    HD 483.1 : 200S2 SOUND SYSTEM EQUIPMENT - GENERAL
    EN 61000-3-2:2014 Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)
    IEC 60268-1:1985 Sound system equipment. Part 1: General
    EN 61000-4-4:2012 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-4: TESTING AND MEASUREMENT TECHNIQUES - ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST (IEC 61000-4-4:2012)
    CISPR 11:2015 RLV Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement
    EN 55103-1:2009/A1:2012 ELECTROMAGNETIC COMPATIBILITY - PRODUCT FAMILY STANDARD FOR AUDIO, VIDEO, AUDIO-VISUAL AND ENTERTAINMENT LIGHTING CONTROL APPARATUS FOR PROFESSIONAL USE - PART 1: EMISSIONS
    EN 61000-4-6:2014/AC:2015 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-6: TESTING AND MEASUREMENT TECHNIQUES - IMMUNITY TO CONDUCTED DISTURBANCES, INDUCED BY RADIO-FREQUENCY FIELDS (IEC 61000-4-6:2013)
    IEC 61000-6-2 : 3.0:2016 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-2: GENERIC STANDARDS - IMMUNITY STANDARD FOR INDUSTRIAL ENVIRONMENTS
    IEC 61000-3-2 : 4.0 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 3-2: LIMITS - LIMITS FOR HARMONIC CURRENT EMISSIONS (EQUIPMENT INPUT CURRENT <= 16 A PER PHASE)