• I.S. EN 60099-9:2014

    Current The latest, up-to-date edition.

    SURGE ARRESTERS - PART 9: METAL-OXIDE SURGE ARRESTERS WITHOUT GAPS FOR HVDC CONVERTER STATIONS

    Available format(s):  Hardcopy, PDF

    Language(s):  English

    Published date:  01-01-2014

    Publisher:  National Standards Authority of Ireland

    For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.
    Only cited Standards give presumption of conformance to New Approach Directives/Regulations.

    Dates of withdrawal of national standards are available from NSAI.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    FOREWORD
    1 Scope
    2 Normative references
    3 Terms and definitions
    4 Typical HVDC converter station schemes,
       arrester types, locations and operating voltage
    5 Identification and classification
    6 Service conditions
    7 Requirements
    8 General testing procedure
    9 Type tests (design tests)
    10 Routine tests and acceptance test
    11 Test requirements on different types of arresters
    Annex A (normative) - Test to verify thermal equivalency
            between complete arrester and arrester section
    Annex B (normative) - Determination of the start
            temperature in the thermal recovery test
    Annex C (normative) - Mechanical considerations
    Annex D (informative) - Different circuit configurations
    Bibliography
    Annex ZA (normative) - Normative references to
             international publications with their
             corresponding European publications

    Abstract - (Show below) - (Hide below)

    Pertains to non-linear metal-oxide resistor type surge arresters without spark gaps designed to limit overvoltages in HVDC converter stations of two terminal, multiterminal and back-to-back type up to and including an operating voltage of 1100 kV.

    General Product Information - (Show below) - (Hide below)

    Development Note For CENELEC adoptions of IEC publications, please check www.iec.ch to be sure that you have any corrigenda that may apply. (01/2017)
    Document Type Standard
    Publisher National Standards Authority of Ireland
    Status Current

    Standards Referencing This Book - (Show below) - (Hide below)

    IEC 60060-2:2010 High-voltage test techniques - Part 2: Measuring systems
    ISO 4892-1:2016 Plastics Methods of exposure to laboratory light sources Part 1: General guidance
    IEC 60143-2:2012 Series capacitors for power systems - Part 2: Protective equipment for series capacitor banks
    IEC 60270:2000+AMD1:2015 CSV High-voltage test techniques - Partial discharge measurements
    IEC 60143-1:2015 Series capacitors for power systems - Part 1: General
    IEC 62271-200:2011 High-voltage switchgear and controlgear - Part 200: AC metal-enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV
    IEC 60099-4:2014 Surge arresters - Part 4: Metal-oxide surge arresters without gaps for a.c. systems
    CISPR 16-1-1:2015 Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-1: Radio disturbance and immunity measuring apparatus - Measuring apparatus
    IEC 62217:2012 Polymeric HV insulators for indoor and outdoor use - General definitions, test methods and acceptance criteria
    IEC TS 60815-2:2008 Selection and dimensioning of high-voltage insulators intended for use in polluted conditions - Part 2: Ceramic and glass insulators for a.c. systems
    EN 62271-203:2012 High-voltage switchgear and controlgear - Part 203: Gas-insulated metal-enclosed switchgear for rated voltages above 52 kV
    EN 60060-1:2010 High-voltage test techniques - Part 1: General definitions and test requirements
    IEC 60068-2-11:1981 Basic environmental testing procedures - Part 2-11: Tests - Test Ka: Salt mist
    EN 60099-4:2014 Surge arresters - Part 4: Metal-oxide surge arresters without gaps for a.c. systems
    EN 60270:2001/A1:2016 HIGH-VOLTAGE TEST TECHNIQUES - PARTIAL DISCHARGE MEASUREMENTS (IEC 60270:2000/A1:2015)
    IEC TS 60071-5:2002 Insulation co-ordination - Part 5: Procedures for high-voltage direct current (HVDC) converter stations
    EN 60060-2:2011 High-voltage test techniques - Part 2: Measuring systems
    EN 60143-2:2013 Series capacitors for power systems - Part 2: Protective equipment for series capacitor banks
    ISO 4892-3:2016 Plastics Methods of exposure to laboratory light sources Part 3: Fluorescent UV lamps
    EN 60068-2-17:1994 Environmental testing - Part 2: Tests - Test Q: Sealing
    IEC 60068-2-17:1994 Basic environmental testing procedures - Part 2-17: Tests - Test Q: Sealing
    IEC 62271-203:2011 High-voltage switchgear and controlgear - Part 203: Gas-insulated metal-enclosed switchgear for rated voltages above 52 kV
    IEC 60721-3-2:1997 Classification of environmental conditions - Part 3: Classification of groups of environmental parameters and their severities - Section 2: Transportation
    IEC 62271-1:2017 High-voltage switchgear and controlgear - Part 1: Common specifications for alternating current switchgear and controlgear
    CISPR TR 18-2:2017 Radio interference characteristics of overhead power lines and high-voltage equipment - Part 2: Methods of measurement and procedure for determining limits
    IEC 60633:1998+AMD1:2009+AMD2:2015 CSV Terminology for high-voltage direct current (HVDC) transmission
    IEC 60071-2:1996 Insulation co-ordination - Part 2: Application guide
    ISO 4892-2:2013 Plastics — Methods of exposure to laboratory light sources — Part 2: Xenon-arc lamps
    EN 60071-2:1997 Insulation co-ordination - Part 2: Application guide
    EN 60068-2-11:1999 Environmental testing - Part 2: Tests - Test Ka: Salt mist
    EN 60721-3-2:1997 Classification of environmental conditions - Part 3: Classification of groups of environmental parameters and their severities - Section 2: Transportation
    IEC 60060-1:2010 High-voltage test techniques - Part 1: General definitions and test requirements
    IEC 60507:2013 Artificial pollution tests on high-voltage ceramic and glass insulators to be used on a.c. systems
    IEC 60071-1:2006+AMD1:2010 CSV Insulation co-ordination - Part 1: Definitions, principles and rules
    IEC 60068-2-14:2009 Environmental testing - Part 2-14: Tests - Test N: Change of temperature
    IEC TS 60815-1:2008 Selection and dimensioning of high-voltage insulators intended for use in polluted conditions - Part 1: Definitions, information and general principles
    EN 60068-2-14:2009 Environmental testing - Part 2-14: Tests - Test N: Change of temperature
    EN 62217:2013 Polymeric HV insulators for indoor and outdoor use - General definitions, test methods and acceptance criteria
    EN 62271-200:2012/AC:2015 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 200: AC METAL-ENCLOSED SWITCHGEAR AND CONTROLGEAR FOR RATED VOLTAGES ABOVE 1 KV AND UP TO AND INCLUDING 52 KV (IEC 62271-200:2011)
    IEC TS 60815-3:2008 Selection and dimensioning of high-voltage insulators intended for use in polluted conditions - Part 3: Polymer insulators for a.c. systems
    EN 55016-1-1:2010/A2:2014 SPECIFICATION FOR RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS AND METHODS - PART 1-1: RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS - MEASURING APPARATUS (CISPR 16-1-1:2010/A2:2014)
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective