• I.S. EN 62387:2016

    Current The latest, up-to-date edition.

    RADIATION PROTECTION INSTRUMENTATION - PASSIVE INTEGRATING DOSIMETRY SYSTEMS FOR INDIVIDUAL, WORKPLACE AND ENVIRONMENTAL MONITORING OF PHOTON AND BETA RADIATION

    Available format(s):  Hardcopy, PDF

    Language(s):  English

    Published date:  01-01-2016

    Publisher:  National Standards Authority of Ireland

    For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.
    Only cited Standards give presumption of conformance to New Approach Directives/Regulations.

    Dates of withdrawal of national standards are available from NSAI.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    National Foreword
    FOREWORD
    INTRODUCTION
    1 Scope
    2 Normative references
    3 Terms and definitions
    4 Units and symbols
    5 General test procedures
    6 Performance requirements: summary
    7 Capability of a dosimetry system
    8 Requirements for the design of the dosimetry system
    9 Instruction manual
    10 Software, data and interfaces of the
       dosimetry system
    11 Radiation performance requirements
       and tests (dosimetry system)
    12 Response to mixed irradiation
       (dosimetry system)
    13 Environmental performance
       requirements and tests
    14 Electromagnetic performance requirements
       and tests (dosimetry system)
    15 Mechanical performance requirements
       and tests
    16 Documentation
    Annex A (normative) - Confidence limits
    Annex B (informative) - Causal connection between
            readout signals, indicated value and measured value
    Annex C (informative) - Overview of the necessary
            actions that have to be performed for a type test
            according to this standard
    Annex D (informative) - Usage categories of
            passive dosemeters;
    Annex E (informative) - Uncertainty of
            dosimetry systems
    Annex F (informative) - Conversion coefficients
            H[pK](3;alpha), h[pK](0,07;alpha), and h
            [K](0,07;alpha) from air kerma, K[a], to
            the dose equivalent H[p](3), H[p](0,07), and
            H (0,07), respectively, for radiation qualities
            defined in ISO 4037-1
    Annex G (informative) - Conversion coefficients
            h[pD](0,07;source;alpha) and h[pD](3;source;
            alpha) from personal absorbed dose in 0,07 mm
            depth, D[p](0,07), to the dose equivalent H[p](0,07)
            and H[p](3), respectively, for radiation qualities
            defined in ISO 6980-1
    Annex H (informative) - Computational
            method of test for mixed irradiations
    Bibliography

    Abstract - (Show below) - (Hide below)

    Pertains to all kinds of passive dosimetry systems that are used for measuring: - the personal dose equivalent H[p](10) (for whole body dosimetry), - the personal dose equivalent H[p](3) (for eye lens dosimetry), - the personal dose equivalent H[p](0,07) (for both whole body and extremity dosimetry), - the ambient dose equivalent H*(10) (for environmental dosimetry), or - the directional dose equivalent H'(0,07) (for environmental dosimetry).

    General Product Information - (Show below) - (Hide below)

    Development Note Supersedes I.S. EN 62387-1. (04/2016) For CENELEC adoptions of IEC publications, please check www.iec.ch to be sure that you have any corrigenda that may apply. (01/2017)
    Document Type Standard
    Publisher National Standards Authority of Ireland
    Status Current
    Supersedes

    Standards Referencing This Book - (Show below) - (Hide below)

    IEC 61000-4-8 : 2.0 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-8: TESTING AND MEASUREMENT TECHNIQUES - POWER FREQUENCY MAGNETIC FIELD IMMUNITY TEST
    EN 60904-3:2016 Photovoltaic devices - Part 3: Measurement principles for terrestrial photovoltaic (PV) solar devices with reference spectral irradiance data
    IEC TR 62461:2015 Radiation protection instrumentation - Determination of uncertainty in measurement
    ISO 4037-4:2004 X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy Part 4: Calibration of area and personal dosemeters in low energy X reference radiation fields
    ISO 6980-3:2006 Nuclear energy — Reference beta-particle radiation — Part 3: Calibration of area and personal dosemeters and the determination of their response as a function of beta radiation energy and angle of incidence
    IEC 61000-4-4 : 3.0EN+(REDLINE+VERSION) ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-4: TESTING AND MEASUREMENT TECHNIQUES - ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST
    ISO 6980-2:2004 Nuclear energy — Reference beta-particle radiation — Part 2: Calibration fundamentals related to basic quantities characterizing the radiation field
    EN 60359:2002 Electrical and electronic measurement equipment - Expression of performance
    EN 61000-4-11:2004/A1:2017 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-11: TESTING AND MEASUREMENT TECHNIQUES - VOLTAGE DIPS, SHORT INTERRUPTIONS AND VOLTAGE VARIATIONS IMMUNITY TESTS (IEC 61000-4-11:2004/A1:2017)
    IEC 61000-4-11:2004+AMD1:2017 CSV Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests
    IEC 60904-3 : 3.0 PHOTOVOLTAIC DEVICES - PART 3: MEASUREMENT PRINCIPLES FOR TERRESTRIAL PHOTOVOLTAIC (PV) SOLAR DEVICES WITH REFERENCE SPECTRAL IRRADIANCE DATA
    ISO 12794:2000 Nuclear energy Radiation protection Individual thermoluminescence dosemeters for extremities and eyes
    EN 61000-4-2:2009 Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
    IEC 60068-2-31:2008 Environmental testing - Part 2-31: Tests - Test Ec: Rough handling shocks, primarily for equipment-type specimens
    ISO 4037-2:1997 X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy Part 2: Dosimetry for radiation protection over the energy ranges from 8 keV to 1,3 MeV and 4 MeV to 9 MeV
    IEC 61000-4-6 : 4.0 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-6: TESTING AND MEASUREMENT TECHNIQUES - IMMUNITY TO CONDUCTED DISTURBANCES, INDUCED BY RADIO-FREQUENCY FIELDS
    EN 61000-4-3 : 2006 AMD 2 2010 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-3: TESTING AND MEASUREMENT TECHNIQUES - RADIATED, RADIO-FREQUENCY, ELECTROMAGNETIC FIELD IMMUNITY TEST
    EN 61000-6-2:2005/corrigendum:2005 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-2: GENERIC STANDARDS - IMMUNITY FOR INDUSTRIAL ENVIRONMENTS (IEC 61000-6-2:2005)
    EN 61000-4-8:2010 Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test
    IEC 61000-4-2:2008 Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
    IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test
    ISO 6980-1:2006 Nuclear energy — Reference beta-particle radiation — Part 1: Methods of production
    ISO 4037-1:1996 X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy Part 1: Radiation characteristics and production methods
    IEC 60359:2001 Electrical and electronic measurement equipment - Expression of performance
    EN 61000-4-4:2012 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-4: TESTING AND MEASUREMENT TECHNIQUES - ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST (IEC 61000-4-4:2012)
    EN 61000-4-6:2014/AC:2015 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-6: TESTING AND MEASUREMENT TECHNIQUES - IMMUNITY TO CONDUCTED DISTURBANCES, INDUCED BY RADIO-FREQUENCY FIELDS (IEC 61000-4-6:2013)
    IEC 61000-6-2 : 3.0:2016 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-2: GENERIC STANDARDS - IMMUNITY STANDARD FOR INDUSTRIAL ENVIRONMENTS
    ISO 4037-3:1999 X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy Part 3: Calibration of area and personal dosemeters and the measurement of their response as a function of energy and angle of incidence
    ISO/IEC Guide 98-3:2008 Uncertainty of measurement — Part 3: Guide to the expression of uncertainty in measurement (GUM:1995)
    EN 60068-2-31:2008 ENVIRONMENTAL TESTING - PART 2-31: TESTS - TEST EC: ROUGH HANDLING SHOCKS, PRIMARILY FOR EQUIPMENT-TYPE SPECIMENS
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective