• I.S. HD 60364-4-42:2011

    Withdrawn A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

    LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 4-42: PROTECTION FOR SAFETY - PROTECTION AGAINST THERMAL EFFECTS

    Available format(s):  Hardcopy, PDF

    Withdrawn date:  04-01-2015

    Language(s):  English

    Published date:  31-12-2010

    Publisher:  National Standards Authority of Ireland

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    FOREWORD
    420.1 Scope
    420.2 Normative references
    420.3 Terms and definitions
    421 Protection against fire caused by electrical
        equipment
        421.1 General requirements
    422 Precautions where particular risks of fire exist
        422.1 General
        422.2 Conditions of evacuation in an emergency
        422.3 Locations with risks of fire due to the nature
              of processed or stored materials
        422.4 Locations with combustible constructional
              materials
        422.5 Fire propagating structures
        422.6 Selection and erection of installations in
              locations with endangering of irreplaceable
              goods
    423 Protection against burns
    424 Protection against overheating
        424.1 Forced air heating systems
        424.2 Appliances producing hot water or steam
        424.3 Space heating appliances
    Annex A (informative) - List of notes concerning certain
            countries
    Bibliography
    Annex ZA (normative) - Normative references to international
             publications with their corresponding European
             publications
    Annex ZB (normative) - Special national conditions
    Annex ZC (informative) - A-deviations
    Annex ZD (informative) - B-deviations

    Abstract - (Show below) - (Hide below)

    Pertains to electrical installations with regard to measures for the protection of persons, livestock and property against: - thermal effects, combustion or degradation of materials, and risk of burns caused by electrical equipment, - flames in case of a fire hazard being propagated from electrical installations to other fire compartments segregated by barriers which are in the vicinity, and - the impairment of the safe functioning of electrical equipment including safety services.

    General Product Information - (Show below) - (Hide below)

    Document Type Standard
    Publisher National Standards Authority of Ireland
    Status Withdrawn

    Standards Referencing This Book - (Show below) - (Hide below)

    IEC 61537:2006 Cable management - Cable tray systems and cable ladder systems
    IEC 60364-4-43:2008 Low-voltage electrical installations - Part 4-43: Protection for safety - Protection against overcurrent
    IEC 60332-3-25:2000+AMD1:2008 CSV Tests on electric and optical fibre cables under fire conditions - Part 3-25: Test for vertical flame spread of vertically-mounted bunched wires or cables - Category D
    IEC 60364-7-753:2014 Low-voltage electrical installations - Part 7-753: Requirements for special installations or locations - Heating cables and embedded heating systems
    IEC 60702-1:2002+AMD1:2015 CSV Mineral insulated cables and their terminations with a rated voltage not exceeding 750 V - Part 1: Cables
    IEC 60670-1:2015 Boxes and enclosures for electrical accessories for household and similar fixed electrical installations - Part 1: General requirements
    IEC 60695-4:2012 Fire hazard testing - Part 4: Terminology concerning fire tests for electrotechnical products
    IEC 60364-4-41:2005+AMD1:2017 CSV Low voltage electrical installations - Part 4-41: Protection for safety - Protection against electric shock
    IEC 60332-3-23:2000+AMD1:2008 CSV Tests on electric and optical fibre cables under fire conditions - Part 3-23: Test for vertical flame spread of vertically-mounted bunched wires or cables - Category B
    IEC 60364-5-51:2005 Electrical installations of buildings - Part 5-51: Selection and erection of electrical equipment - Common rules
    HD 60364-4-41:2017/A11:2017 LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 4-41: PROTECTION FOR SAFETY - PROTECTION AGAINST ELECTRIC SHOCK
    IEC 60050-442:1998 International Electrotechnical Vocabulary (IEV) - Part 442: Electrical accessories
    IEC 60332-3-24:2000+AMD1:2008 CSV Tests on electric and optical fibre cables under fire conditions - Part 3-24: Test for vertical flame spread of vertically-mounted bunched wires or cables - Category C
    HD 60364-5-51:2009/A12:2017 ELECTRICAL INSTALLATIONS OF BUILDINGS - PART 5-51: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - COMMON RULES
    EN 60598-2-24:2013 LUMINAIRES - PART 2-24: PARTICULAR REQUIREMENTS - LUMINAIRES WITH LIMITED SURFACE TEMPERATURES (IEC 60598-2-24:2013)
    IEC 60332-1-2:2004+AMD1:2015 CSV Tests on electric and optical fibre cables under fire conditions - Part 1-2: Test for vertical flame propagation for a single insulatedwire or cable - Procedure for 1 kW pre-mixed flame
    IEC 61084-1:2017 Cable trunking systems and cable ducting systems for electrical installations - Part 1: General requirements
    IEC 60364-4-44:2007+AMD1:2015 CSV Low-voltage electrical installations - Part 4-44: Protection for safety - Protection against voltage disturbances and electromagnetic disturbances
    EN 50272-2:2001 Safety requirements for secondary batteries and battery installations - Part 2: Stationary batteries
    IEC 60598-1:2014+AMD1:2017 CSV Luminaires - Part 1: General requirements and tests
    IEC 60331-21:1999 Tests for electric cables under fire conditions - Circuit integrity - Part 21: Procedures and requirements - Cables of rated voltage up to and including 0,6/1,0 kV
    IEC 60332-3-21:2000 Tests on electric cables under fire conditions - Part 3-21: Test for vertical flame spread of vertically-mounted bunched wires or cables - Category A F/R
    IEC 60079-14:2013 Explosive atmospheres - Part 14: Electrical installations design, selection and erection
    IEC 62020:1998+AMD1:2003 CSV Electrical accessories - Residual current monitors for household and similar uses (RCMs)
    IEC 61386-1:2008+AMD1:2017 CSV Conduit systems for cable management - Part 1: General requirements
    IEC 60331-1:2009 Tests for electric cables under fire conditions - Circuit integrity - Part 1: Test method for fire with shock at a temperature of at least 830 °C for cables of rated voltage up to and including 0,6/1,0 kV and with an overall diameter exceeding 20 mm
    IEC 61439-1:2011 Low-voltage switchgear and controlgear assemblies - Part 1: General rules
    IEC 60598-2-24:2013 Luminaires - Part 2-24: Particular requirements - Luminaires with limited surface temperatures
    IEC 60364-5-55:2011+AMD1:2012+AMD2:2016 CSV Electrical installations of buildings - Part 5-55: Selection and erection of electrical equipment - Other equipment
    IEC 60947-2:2016 Low-voltage switchgear and controlgear - Part 2: Circuit-breakers
    EN 61537:2007 Cable management - Cable tray systems and cable ladder systems
    IEC 60332-3-22:2000+AMD1:2008 CSV Tests on electric and optical fibre cables under fire conditions - Part 3-22: Test for vertical flame spread of vertically-mounted bunched wires or cables - Category A
    IEC 61034-2:2005+AMD1:2013 CSV Measurement of smoke density of cables burning under definedconditions - Part 2: Test procedure and requirements
    IEC 60364-5-52:2009 Low-voltage electrical installations - Part 5-52: Selection and erection of electrical equipment - Wiring systems
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective