• IEC 60332-3-21:2000

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    Tests on electric cables under fire conditions - Part 3-21: Test for vertical flame spread of vertically-mounted bunched wires or cables - Category A F/R

    Available format(s):  Hardcopy, PDF, PDF 3 Users, PDF 5 Users, PDF 9 Users

    Superseded date:  12-09-2022

    Language(s):  English - French, Spanish, Castilian

    Published date:  09-10-2000

    Publisher:  International Electrotechnical Committee

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    FOREWORD
    INTRODUCTION
    1 Scope
    2 Normative references
    3 Definitions
    4 Test apparatus
          4.1 General
          4.2 Ignition source
    5 Test procedure
          5.1 Test sample
          5.2 Determination of the number of test pieces
          5.3 Mounting of the test sample
          5.4 Flame application time
    6 Evaluation of test results
    7 Performance requirements
    8 Retest procedure
    9 Test report
    Annex A (normative) Guidance on cable selection for type
                        approval testing
    Annex B (informative) Recommended performance requirements
    Figure 1 - Typical arrangement and spacing of cables mounted
               on both sides of the standard ladder (category
               A F/R)
    Table A.1 - Summary of test conditions

    Abstract - (Show below) - (Hide below)

    IEC 60332-3-21:2000 Specifies method of test for the assessment of vertical flame spread of vertically-mounted bunched wires or cables, electrical or optical, under defined conditions. The test is intended for type approval testing. The requirements for the selection of cables for testing are given. The flame spread is measured as the extent of damage of the cable sample. This procedure may be used to demonstrate the cable's ability to limit flame spread. Covers category A F/R and relates only to power cables of conductor cross-sectional area greater than 35 mm2 installed on the test ladder in a spaced configuration on the front and rear to achieve a nominal total volume of non-metallic material of 7 l/m of test sample. The flame application time is 40 min. This method of mounting is intended for special cable designs used in particular installations when required in the cable specification. Category A F/R is not intended for general use. A recommended performance requirement is also given.It has the status of a horizontal standard in accordance with IEC Guide 104.

    General Product Information - (Show below) - (Hide below)

    Committee TC 20
    Development Note Supersedes IEC 60332-3 (03/2001) Stability Date: 2017. (09/2017)
    Document Type Standard
    Publisher International Electrotechnical Committee
    Status Superseded
    Superseded By

    Standards Referenced By This Book - (Show below) - (Hide below)

    S.R. HD 60364-4-42:2011 LOW VOLTAGE ELECTRICAL INSTALLATIONS - PART 4-42: PROTECTION FOR SAFETY - PROTECTION AGAINST THERMAL EFFECTS
    IEEE 525-2007 IEEE Guide for the Design and Installation of Cable Systems in Substations
    EN 60695-9-2:2014 Fire hazard testing - Part 9-2: Surface spread of flame - Summary and relevance of test methods
    DIN EN 12601:2011-07 RECIPROCATING INTERNAL COMBUSTION ENGINE DRIVEN GENERATING SETS - SAFETY
    HD 620 : 2010 DISTRIBUTION CABLES WITH EXTRUDED INSULATION FOR RATED VOLTAGES FROM 3,6/6 (7,2) KV UP TO AND INCLUDING 20,8/36 (42) KV
    EN 12601:2010 Reciprocating internal combustion engine driven generating sets - Safety
    HD 60364-4-42 : 2011 AMD 1 2015 LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 4-42: PROTECTION FOR SAFETY - PROTECTION AGAINST THERMAL EFFECTS (IEC 60364-4-42:2010/A1:2014)
    10/30211242 DC : 0 BS EN 12601 - RECIPROCATING INTERNAL COMBUSTION ENGINE DRIVEN GENERATING SETS - SAFETY
    PREN 12601 : DRAFT 2010 RECIPROCATING INTERNAL COMBUSTION ENGINE DRIVEN GENERATING SETS - SAFETY
    I.S. EN 60695-9-2:2014 FIRE HAZARD TESTING - PART 9-2: SURFACE SPREAD OF FLAME - SUMMARY AND RELEVANCE OF TEST METHODS
    BS EN 12601:2010 Reciprocating internal combustion engine driven generating sets. Safety
    I.S. HD 60364-4-42:2011 LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 4-42: PROTECTION FOR SAFETY - PROTECTION AGAINST THERMAL EFFECTS
    UNE-EN 60695-9-2:2014 Fire hazard testing - Part 9-2: Surface spread of flame - Summary and relevance of test methods
    IEC TS 60695-9-2:2005 Fire hazard testing - Part 9-2: Surface spread of flame - Summary and relevance of test methods
    IEC 60695-9-2:2014 Fire hazard testing - Part 9-2: Surface spread of flame - Summary and relevance of test methods
    UNI EN 12601 : 2011 RECIPROCATING INTERNAL COMBUSTION ENGINE DRIVEN GENERATING SETS - SAFETY
    I.S. EN 12601:2010 RECIPROCATING INTERNAL COMBUSTION ENGINE DRIVEN GENERATING SETS - SAFETY
    CEI 20-22/0 : 2006 TEST ON ELECTRIC CABLES UNDER FIRE CONDITIONS - PART 0: TEST OF NO PROPAGATION OF FIRE - GENERAL PRINCIPLES
    IEC 60364-4-42:2010+AMD1:2014 CSV Low-voltage electrical installations - Part 4-42: Protection forsafety - Protection against thermal effects
    I.S. HD 620:2010 DISTRIBUTION CABLES WITH EXTRUDED INSULATION FOR RATED VOLTAGES FROM 3,6/6 (7,2) KV UP TO AND INCLUDING 20,8/36 (42) KV
    DD IEC TS 60695-9-2 : DRAFT 2005 FIRE HAZARD TESTING - PART 9-2: SURFACE SPREAD OF FLAME - SUMMARY AND RELEVANCE OF TEST METHODS
    BS EN 60695-9-2:2014 Fire hazard testing Surface spread of flame. Summary and relevance of test methods
    UNE-EN 12601:2011 Reciprocating internal combustion engine driven generating sets - Safety
    UNE-HD 60364-4-42:2014 Low voltage electrical installations -- Part 4-42: Protection for safety - Protection against thermal effects

    Standards Referencing This Book - (Show below) - (Hide below)

    AS/NZS IEC 60332.1.2:2017 Tests on electric and optical fibre cables under fire conditions Test for vertical flame propagation for a single insulated wire or cable - Procedure for 1 kW pre-mixed flame
    IEC 60695-4:2012 Fire hazard testing - Part 4: Terminology concerning fire tests for electrotechnical products
    IEC 60811-1-3:1993+AMD1:2001 CSV Common test methods for insulating and sheathing materials of electric and optical cables - Part 1-3: General application -Methods for determining the density - Water absorption tests - Shrinkage test
    IEC 60332-3-10:2000+AMD1:2008 CSV Tests on electric and optical fibre cables under fire conditions - Part 3-10: Test for vertical flame spread of vertically-mounted bunched wires or cables - Apparatus
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective