• IEC 61000-6-6:2003

    Current The latest, up-to-date edition.

    Electromagnetic compatibility (EMC) - Part 6-6: Generic standards - HEMP immunity for indoor equipment

    Available format(s):  Hardcopy, PDF, PDF 3 Users, PDF 5 Users, PDF 9 Users

    Language(s):  English - French

    Published date:  09-04-2003

    Publisher:  International Electrotechnical Committee

    Add To Cart

    Abstract - (Show below) - (Hide below)

    This part of IEC 61000 sets high-altitude electromagnetic pulse (HEMP) immunity requirements for electrical and electronic equipment intended for use indoors. The indoor HEMP environment depends on the electromagnetic shielding quality of a facility and the level of protection against the conducted environment. This standard is intended for all facility types including residential, commercial, light industrial, hospitals, heavy industrial, power substations and power generation facilities. This standard includes indoor equipment intended to be connected to a low-voltage (1 kV or less) power network, to the telecom network and/or to external antennas. Immunity test values are based on the 90 % severity levels in IEC 61000-4-25. All telecom lines are assumed to have gas-tube protectors at the point where they enter the building and insulation flashover on low-voltage lines are assumed at three times that of lightning. For signal ports connected to internal cables, severity test levels are based on cables that have a total length of 10 m and a procedure is provided for longer cables. This part of IEC 61000 does not specify safety requirements for equipment, such as protection against shock, insulation coordination, and related dielectric tests. Nevertheless, the immunity tests described in this part of IEC 61000 involve hazardous voltages. High-voltage precautions are necessary to protect the health and safety of test personnel.

    General Product Information - (Show below) - (Hide below)

    Committee TC 77/SC 77C
    Development Note Stability date: 2018. (11/2017)
    Document Type Standard
    Publisher International Electrotechnical Committee
    Status Current

    Standards Referenced By This Book - (Show below) - (Hide below)

    05/30136204 DC : DRAFT JUL 2005
    IEC TS 61000-5-8:2009 Electromagnetic compatibility (EMC) - Part 5-8: Installation and mitigation guidelines - HEMP protection methods for the distributed infrastructure
    BS IEC 62003:2009 Nuclear power plants. Instrumentation and control important to safety. Requirements for electromagnetic compatibility testing
    PD IEC/TS 61000-5-10:2017 Electromagnetic compatibility (EMC) Installation and mitigation guidelines. Guidance on the protection of facilities against HEMP and IEMI
    I.S. EN 61000-4-18:2007 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-18: TESTING AND MEASUREMENT TECHNIQUES - DAMPED OSCILLATORY WAVE IMMUNITY TEST
    IEC TS 61000-5-9:2009 Electromagnetic compatibility (EMC) - Part 5-9: Installation and mitigation guidelines - System-level susceptibility assessments for HEMP and HPEM
    IEC 61000-4-18:2006+AMD1:2010 CSV Electromagnetic compatibility (EMC) - Part 4-18: Testing and measurement techniques - Damped oscillatory wave immunity test
    08/30181498 DC : DRAFT APR 2008 BS EN 61000-5-8 - ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 5-8: INSTALLATION AND MITIGATION GUIDELINES - HEMP PROTECTION METHODS FOR THE DISTRIBUTED INFRASTRUCTURE
    DD IEC/TS 61000-5-9:2009 Electromagnetic compatibility (EMC) Installation and mitigation guidelines. System-level susceptibility assessments for HEMP and HPEM
    DD IEC/TS 61000-5-8:2009 Electromagnetic compatibility (EMC) Installation and mitigation guidelines. HEMP protection methods for the distributed infrastructure
    NF EN 61000-4-18 : 2007 AMD 1 2011 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-18: TESTING AND MEASUREMENT TECHNIQUES - DAMPED OSCILLATORY WAVE IMMUNITY TEST
    BS EN 61000-4-18 : 2007 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-18: TESTING AND MEASUREMENT TECHNIQUES - DAMPED OSCILLATORY WAVE IMMUNITY TEST
    16/30316578 DC : 0 BS EN ISO 13766-1 - EARTH-MOVING- AND BUILDING CONSTRUCTION MACHINERY - ELECTROMAGNETIC COMPATIBILITY OF MACHINES WITH INTERNAL ELECTRICAL POWER SUPPLY - PART 1: GENERAL EMC REQUIREMENTS UNDER TYPICAL EMC ENVIRONMENTAL CONDITIONS
    IEEE 1642-2015 IEEE Recommended Practice for Protecting Publicly Accessible Computer Systems from Intentional Electromagnetic Interference (IEMI)
    CEI EN 50090-9-1 : 2005 HOME AND BUILDING ELECTRONIC SYSTEMS (HBES) - PART 9-1: INSTALLATION REQUIREMENTS - GENERIC CABLING FOR HBES CLASS 1 TWISTED PAIR
    IEC TS 61000-5-10:2017 Electromagnetic compatibility (EMC) - Part 5-10: Installation and mitigation guidelines - Guidance on the protection of facilities against HEMP and IEMI
    CAN/CSA-IEC 61000-4-18:14 (R2018) Electromagnetic compatibility (EMC) - Part 4-18: Testing and measurement techniques - Damped oscillatory wave immunity test (Adopted IEC 61000-4-18:2011, edition 1:2006 consolidated with amendment 1:2010) | Compatibilité électromagnétique (CEM) - Partie 4-18 : Techniques d\'essai et de mesure - Essai d\'immunité à l\'onde oscillatoire amortie (norme CEI 61000-4-18:2011 adoptée, édition 1:2006 consolidée par l\'amendement 1:2010)
    IEC 62003:2009 Nuclear power plants - Instrumentation and control important to safety - Requirements for electromagnetic compatibility testing

    Standards Referencing This Book - (Show below) - (Hide below)

    IEC TR 61000-5-3:1999 Electromagnetic compatibility (EMC) - Part 5-3: Installation and mitigation guidelines - HEMP protection concepts
    IEC 61024-1:1990 Protection of structures against lightning - Part 1: General principles
    IEC 61000-2-10:1998 Electromagnetic compatibility (EMC) - Part 2-10: Environment - Description of HEMP environment - Conducted disturbance
    IEC 60068-1:2013 Environmental testing - Part 1: General and guidance
    IEC 61000-4-4 : 3.0EN+(REDLINE+VERSION) ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-4: TESTING AND MEASUREMENT TECHNIQUES - ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST
    IEC 61000-2-11:1999 Electromagnetic compatibility (EMC) - Part 2-11: Environment - Classification of HEMP environments
    IEC 61000-6-2:2016 Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity standard for industrial environments
    IEC 61000-4-11:2004+AMD1:2017 CSV Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests
    IEC 61000-4-25:2001+AMD1:2012 CSV Electromagnetic compatibility (EMC) - Part 4-25: Testing and measurement techniques - HEMP immunity test methods for equipment and systems
    IEC 61000-4-4:2012 RLV Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
    IEC 61643-21:2000+AMD1:2008+AMD2:2012 CSV Low voltage surge protective devices - Part 21: Surge protective devices connected to telecommunications and signalling networks - Performance requirements and testing methods
    IEC TS 61000-6-5:2001 Electromagnetic compatibility (EMC) - Part 6-5: Generic standards - Immunity for power station and substation environments
    IEC 61000-4-20:2010 Electromagnetic compatibility (EMC) - Part 4-20: Testing and measurement techniques - Emission and immunity testing in transverse electromagnetic (TEM) waveguides
    IEC 61000-4-2:2008 Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
    ISO 7137:1995 Aircraft — Environmental conditions and test procedures for airborne equipment
    IEC 61000-2-9:1996 Electromagnetic compatibility (EMC) - Part 2: Environment - Section 9: Description of HEMP environment - Radiated disturbance. Basic EMC publication
    IEC 61000-6-2 : 3.0:2016 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-2: GENERIC STANDARDS - IMMUNITY STANDARD FOR INDUSTRIAL ENVIRONMENTS
    IEC 61000-4-13:2002+AMD1:2009+AMD2:2015 CSV Electromagnetic compatibility (EMC) - Part 4-13: Testing and measurement techniques - Harmonics and interharmonics includingmains signalling at a.c. power port, low frequency immunity tests
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective