• IEC 61010-2-041:1995

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-041: Particular requirements for autoclaves using steam for the treatment of medical materials, and for laboratory processes

    Available format(s):  Hardcopy, PDF, PDF 3 Users, PDF 5 Users, PDF 9 Users

    Superseded date:  14-04-2005

    Language(s):  English - French, Spanish, Castilian

    Published date:  19-12-1995

    Publisher:  International Electrotechnical Committee

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    Foreword
    Introduction
    Clause
    1 Scope and object
    2 Normative references
    3 Definitions
    4 Tests
    5 Marking and documentation
    6 Protection against electric shock
    7 Protection against mechanical hazards
    8 Mechanical resistance to shock and impact
    9 Equipment temperature limits and protection against
       the spread of fire
    10 Resistance to heat
    11 Protection against hazards from fluids
    12 Protection against radiation, including laser sources,
       and against sonic and ultrasonic pressure
    13 Protection against liberated gases, explosion and
       implosion
    14 Components
    15 Protection by interlocks
    16 Measuring circuits
    Annexes

    Abstract - (Show below) - (Hide below)

    Replacement: Applies to AUTOCLAVES, including those with anautomatic loading and unloading system, which incorporate aPRESSURE VESSEL, using steam within the absolute pressure rangefrom 0 to 500 kPa, and intended for the treatment of medicalmaterials and for laboratory processes, for example forsterilization.This standard has the status of a group safety publication.

    General Product Information - (Show below) - (Hide below)

    Development Note Also numbered as BS EN 61010-2.041. (12/2005)
    Document Type Standard
    Publisher International Electrotechnical Committee
    Status Superseded
    Superseded By

    Standards Referenced By This Book - (Show below) - (Hide below)

    02/124462 DC : DRAFT DEC 2002 BS EN 285 - STERILIZATION - STEAM STERILIZERS - LARGE STERILIZERS
    CSA Z15190 : 2005 : R2010 MEDICAL LABORATORIES - REQUIREMENTS FOR SAFETY
    PD 6632:1998 Biotechnology. Laboratories for research, development and analysis. Guidance on the selection of equipment needed for biotechnology laboratories according to the degree of hazard
    EN 12738:1999 Biotechnology - Laboratories for research, development and analysis - Guidance for containment of animals inoculated with microorganisms in experiments
    EN 12128:1998 Biotechnology - Laboratories for research, development and analysis - Containment levels of microbiology laboratories, areas of risk, localities and physical safety requirements
    98/123927 DC : DRAFT AUG 1998 PREN 61010-2-045 - SAFETY REQUIREMENTS FOR ELECTRICAL EQUIPMENT FOR MEASUREMENT, CONTROL ADN LABORATORY USE, PART 2-045: PARTICULAR REQUIREMENTS FOR WASHER-DISINFECTORS USED IN MEDICAL, PHARMACEUTICAL, VETERINARY AND LABORATORY FIELDS
    ISO 13683:1997 Sterilization of health care products Requirements for validation and routine control of moist heat sterilization in health care facilities
    ISO 15190:2003 Medical laboratories Requirements for safety
    BS ISO 15190:2003 Medical laboratories. Requirements for safety
    CSA Z15190 : 2005 : R2015 MEDICAL LABORATORIES - REQUIREMENTS FOR SAFETY
    CSA Z15190 : 2005 MEDICAL LABORATORIES - REQUIREMENTS FOR SAFETY
    BS EN 12738:1999 Biotechnology. Laboratories for research, development and analysis. Guidance for containment of animals inoculated with microorganisms in experiments
    BS EN 12740:1999 Biotechnology. Laboratories for research, development and analysis. Guidance for handling, inactivating and testing of waste
    BS EN 12128:1998 Biotechnology. Laboratories for research, development and analysis. Containment levels of microbiology laboratories, areas of risk, localities and physical safety requirements
    02/121895 DC : DRAFT APR 2002 BS EN 13060 - SMALL STEAM STERILIZERS
    CSA ISO 11134 : 0 STERILIZATION OF HEALTH CARE PRODUCTS - REQUIREMENTS FOR VALIDATION AND ROUTINE CONTROL - INDUSTRIAL MOIST HEAT STERILIZATION
    04/30048301 DC : DRAFT MAY 2004 BS EN ISO 11137-1 - STERILIZATION OF HEALTH CARE PRODUCTS - RADIATION - PART 1: REQUIREMENTS FOR DEVELOPMENT, VALIDATION AND ROUTINE CONTROL OF A STERILIZATION PROCESS FOR MEDICAL DEVICES
    ISO 11134:1994 Sterilization of health care products — Requirements for validation and routine control — Industrial moist heat sterilization

    Standards Referencing This Book - (Show below) - (Hide below)

    ISO 6718:1991 Bursting discs and bursting disc devices
    ISO 3585:1998 Borosilicate glass 3.3 Properties