• IEC 61095:2009

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    Electromechanical contactors for household and similar purposes

    Available format(s):  Hardcopy, PDF, PDF 3 Users, PDF 5 Users, PDF 9 Users

    Superseded date:  12-10-2023

    Language(s):  English - French, Spanish, Castilian

    Published date:  05-02-2009

    Publisher:  International Electrotechnical Committee

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    FOREWORD
    INTRODUCTION
    1 Scope
    2 Normative references
    3 Terms and definitions
      3.1 General terms
      3.2 Switching devices
      3.3 Parts of switching devices
      3.4 Operation of switching devices
      3.5 Characteristic quantities
    4 Classification
    5 Characteristics of contactors
      5.1 Summary of characteristics
      5.2 Type of contactor
          5.2.1 Number of poles
          5.2.2 Method of control
      5.3 Rated and limiting values for main circuits
          5.3.1 General
          5.3.2 Rated voltages
          5.3.3 Currents or powers
          5.3.4 Rated frequency
          5.3.5 Rated duties
          5.3.6 Normal load and overload characteristics
          5.3.7 Rated conditional short-circuit current
      5.4 Utilization category
          5.4.1 General
          5.4.2 Assignment of utilization categories based on
                 the results of tests
      5.5 Control circuits
      5.6 Auxiliary circuits
      5.7 Co-ordination with short-circuit protective devices
    6 Product information
      6.1 Nature of information
          6.1.1 Identification
          6.1.2 Characteristics, basic rated values and utilization
      6.2 Marking
      6.3 Instructions for installation, operation and maintenance
    7 Normal service, mounting and transport conditions
      7.1 Normal service conditions
          7.1.1 Ambient air temperature
          7.1.2 Altitude
          7.1.3 Atmospheric conditions
          7.1.4 Normal electromagnetic environmental conditions
      7.2 Conditions during transport and storage
      7.3 Mounting
    8 Constructional and performance requirements
      8.1 Constructional requirements
          8.1.1 General
          8.1.2 Materials
          8.1.3 Strength of screws or nuts other than those on
                 terminals which are intended to be operated
                 during installation or maintenance
          8.1.4 Vacant
          8.1.5 Actuator
          8.1.6 Indication of the OFF and ON positions
          8.1.7 Terminals
          8.1.8 Additional requirements for contactors provided
                 with a neutral pole
          8.1.9 Provisions for earthing
          8.1.10 Enclosures
          8.1.11 Degrees of protection of enclosed contactors
          8.1.12 Resistance to impact
          8.1.13 Durability of markings
      8.2 Performance requirements
          8.2.1 Operating conditions
          8.2.2 Temperature-rise
          8.2.3 Dielectric properties
          8.2.4 Normal load and overload performance requirements
          8.2.5 Co-ordination with short-circuit protective devices
      8.3 Electromagnetic compatibility
          8.3.1 Immunity
          8.3.2 Emission
    9 Tests
      9.1 Types of test
          9.1.1 General
          9.1.2 Type tests
          9.1.3 Routine tests
          9.1.4 Sampling tests for clearance verification
      9.2 Compliance with constructional requirements
          9.2.1 General
          9.2.2 Materials
          9.2.3 Test on screws or nuts other than those on
                 terminals which are intended to be operated during
                 installation or maintenance
          9.2.4 Verification of the degrees of protection of
                 enclosed contactors
          9.2.5 Mechanical properties of terminals
          9.2.6 Test of resistance to impact
          9.2.7 Test of durability of marking
      9.3 Compliance with performance requirements
          9.3.1 Test sequences
          9.3.2 General test conditions
          9.3.3 Performance under no load, normal load and
                 overload conditions
          9.3.4 Performance under short-circuit conditions
          9.3.5 Overload current withstand capability
          9.3.6 Routine tests
    Annex A (normative) Terminal marking and distinctive number
    Annex B (normative) Test sequences and number of samples
    Annex C (normative) Description of a method for adjusting the
                        load circuit
    Annex D (normative) Determination of short-circuit power-factor
    Annex E (normative) Measurement of creepage distances and
                        clearances
    Annex F (normative) Correlation between the nominal voltage of
                        the supply system and the rated impulse
                        withstand voltage of a contactor
    Annex G (normative) Hot wire ignition test
    Annex H (normative) Degrees of protection of enclosed contactor
    Annex I (normative) Requirements and tests for equipment with
                        protective separation

    Abstract - (Show below) - (Hide below)

    IEC 61095:2009 applies to electromechanical air break contactors for household and similar purposes provided with main contacts intended to be connected to circuits the rated voltage of which does not exceed 440 V a.c. (between phases) with rated operational currents less than or equal to 63 A for utilization category AC-7a and 32 A for utilization categories AC-7b and AC-7c, and rated conditional short-circuit current less than or equal to 6 kA. This second edition cancels and replaces the first edition published in 1992 and its Amendment 1 (2000), and constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
    - deletion of switching overvoltages requirements,
    - addition of a new utilization category AC-7c: switching of compensated electric discharge lamp control,
    - measuring of Uimp required, but the marking is not required if Uimp equal to 4 kV,
    - improvement regarding marking concerning direction of movement,
    - improvement of dielectric properties,
    - test of resistance to humidity referred to IEC 60068-2-78 instead of IEC 60068-2-3,
    - amendment to Table B.1 regarding test sequences,
    - deletion of Table F.2 regarding the correspondence between the nominal voltage of the supply system and the contactor rated impulse withstand voltage,
    - addition of a new Annex H (normative): degrees of protection of enclosed contactor,
    - addition of a new Annex I (normative): requirements and tests for equipment with protective separation.

    General Product Information - (Show below) - (Hide below)

    Committee TC 121/SC 121A
    Development Note Supersedes IEC 60158-3 (03/2001) Stability Date: 2019. (09/2017)
    Document Type Standard
    Publisher International Electrotechnical Committee
    Status Superseded
    Superseded By
    Supersedes

    Standards Referenced By This Book - (Show below) - (Hide below)

    UNE-HD 50573.5.57:2014 Co-ordination of electrical equipment for protection, isolation, switching and control
    16/30350588 DC : 0 BS PD IEC/TS 62446-3 ED 1.0 - PHOTOVOLTAIC (PV) SYSTEMS - REQUIREMENTS FOR TESTING, DOCUMENTATION AND MAINTENANCE - PART 3: OUTDOOR INFRARED THERMOGRAPHY OF PHOTOVOLTAIC MODULES AND PLANTS
    PD IEC/TS 62446-3:2017 Photovoltaic (PV) systems. Requirements for testing, documentation and maintenance Photovoltaic modules and plants. Outdoor infrared thermography
    IEC 62683-1:2017 Low-voltage switchgear and controlgear - Product data and properties for information exchange - Part 1: Catalogue data
    I.S. EN 62683-1:2017 LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PRODUCT DATA AND PROPERTIES FOR INFORMATION EXCHANGE - PART 1: CATALOGUE DATA
    EN 62683-1:2017 Low-voltage switchgear and controlgear - Product data and properties for information exchange - Part 1: Catalogue data
    EN 60947-4-1 : 2010 AMD 1 2012 LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 4-1: CONTACTORS AND MOTOR-STARTERS - ELECTROMECHANICAL CONTACTORS AND MOTOR-STARTERS (IEC 60947-4-1:2009/A1:2012)
    EN 62683:2015 Low-voltage switchgear and controlgear - Product data and properties for information exchange
    I.S. EN 62683:2015 LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PRODUCT DATA AND PROPERTIES FOR INFORMATION EXCHANGE
    EN 60947-1:2007/A2:2014 LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 1: GENERAL RULES (IEC 60947-1:2007/A2:2014)
    IEC TS 62446-3:2017 Photovoltaic (PV) systems - Requirements for testing, documentation and maintenance - Part 3: Photovoltaic modules and plants - Outdoor infrared thermography
    IEC 60947-4-1:2009+AMD1:2012 CSV Low-voltage switchgear and controlgear - Part 4-1: Contactors and motor-starters - Electromechanical contactors and motor-starters
    UNE-EN 60947-4-1:2011 Low-voltage switchgear and controlgear - Part 4-1: Contactors and motor-starters - Electromechanical contactors and motor-starters
    UNE-HD 60364-5-53:2016 Low-voltage electrical installations - Part 5-53: Selection and erection of electrical equipment - Switchgear and controlgear
    BS EN 60947-1 : 2007 LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 1: GENERAL RULES
    S.R. HD 60364-5-537:2016 LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 5-53: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - DEVICES FOR PROTECTION, ISOLATION, SWITCHING, CONTROL AND MONITORING - CLAUSE 537: ISOLATION AND SWITCHING
    CSA C22.2 NO. 60947-4-1:14 (R2019) Low-voltage switchgear and controlgear - Part 4-1: Contactors and motor-starters - Electromechanical contactors and motor-starters ( Bi-national standard, with UL 60947-4-1)
    S.R. HD 60364-5-53:2015 LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 5-53: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - SWITCHGEAR AND CONTROLGEAR
    BS EN 62683:2015 Low-voltage switchgear and controlgear. Product data and properties for information exchange
    07/30169755 DC : 0 BS EN 60364-5-53 - LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 5-53: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - PROTECTION, ISOLATION, SWITCHING, CONTROL AND MONITORING
    13/30292412 DC : 0 BS EN 62683 - PRODUCT DATA AND PROPERTIES FOR INFORMATION EXCHANGE
    IEC 60947-1:2007+AMD1:2010+AMD2:2014 CSV Low-voltage switchgear and controlgear - Part 1: General rules
    DIN 56950:2005-04 ENTERTAINMENT TECHNOLOGY - MACHINERY INSTALLATIONS - SAFETY REQUIREMENTS AND TESTING
    HD 60364-5-537:2016/A11:2017 LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 5-53: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - DEVICES FOR PROTECTION, ISOLATION, SWITCHING, CONTROL AND MONITORING - CLAUSE 537: ISOLATION AND SWITCHING
    BS EN 60947-4-1 : 2010 LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 4-1: CONTACTORS AND MOTOR-STARTERS - ELECTROMECHANICAL CONTACTORS AND MOTOR-STARTERS
    BS EN 62683-1:2017 Low-voltage switchgear and controlgear. Product data and properties for information exchange Catalogue data
    I.S. HD 50573-5-57:2014 CO-ORDINATION OF ELECTRICAL EQUIPMENT FOR PROTECTION, ISOLATION, SWITCHING AND CONTROL
    07/30169774 DC : 0 BS EN 60364-5-53 - LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 5-53: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - PROTECTION, ISOLATION, SWITCHING, CONTROL AND MONITORING
    UNE-EN 62683:2016 Low-voltage switchgear and controlgear - Product data and properties for information exchange
    I.S. EN 60947-1:2007 LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 1: GENERAL RULES
    I.S. EN 60947-4-1:2010 LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 4-1: CONTACTORS AND MOTOR-STARTERS - ELECTROMECHANICAL CONTACTORS AND MOTOR-STARTERS (IEC 60947-4-1:2009 (EQV))
    HD 50573-5-57:2014 Co-ordination of electrical equipment for protection, isolation, switching and control
    BIS IS/IEC 60947-4-1 : 2000 LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 4: CONTACTORS AND MOTOR-STARTERS - SECTION 1: ELECTROMECHANICAL CONTACTORS AND MOTOR-STARTERS
    HD 60364-5-53:2015/A11:2017 LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 5-53: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - SWITCHGEAR AND CONTROLGEAR
    UNE-HD 60364-5-537:2017 Low-voltage electrical installations - Part 5-53: Selection and erection of electrical equipment - Devices for protection, isolation, switching, control and monitoring - Clause 537: Isolation and switching

    Standards Referencing This Book - (Show below) - (Hide below)

    IEC 60112:2003+AMD1:2009 CSV Method for the determination of the proof and the comparative tracking indices of solid insulating materials
    IEC 60028:1925 International standard of resistance for copper
    IEC 60947-4-1:2009+AMD1:2012 CSV Low-voltage switchgear and controlgear - Part 4-1: Contactors and motor-starters - Electromechanical contactors and motor-starters
    SA/SNZ TS 62446.3:2020 Photovoltaic (PV) systems - Requirements for testing, documentation and maintenance Photovoltaic modules and plants - Outdoor infrared thermography (IEC TS 62446-3:2017, MOD)
    IEC 60073:2002 Basic and safety principles for man-machine interface, marking and identification - Coding principles for indicators and actuators
    IEC 60050-151:2001 International Electrotechnical Vocabulary (IEV) - Part 151: Electrical and magnetic devices
    IEC 60050-441:1984 International Electrotechnical Vocabulary (IEV) - Part 441: Switchgear, controlgear and fuses
    IEC 60947-5-1 : 4.0 LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 5-1: CONTROL CIRCUIT DEVICES AND SWITCHING ELEMENTS - ELECTROMECHANICAL CONTROL CIRCUIT DEVICES
    IEC 60695-2-11:2014 Fire hazard testing - Part 2-11: Glowing/hot-wire based test methods - Glow-wire flammability test method for end-products (GWEPT)
    ISO 2039-2:1987 Plastics Determination of hardness Part 2: Rockwell hardness
    IEC 60085:2007 Electrical insulation - Thermal evaluation and designation
    IEC 60447:2004 Basic and safety principles for man-machine interface, marking and identification - Actuating principles
    IEC 60529:1989+AMD1:1999+AMD2:2013 CSV Degrees of protection provided by enclosures (IP Code)
    IEC 60364-4-44:2007+AMD1:2015 CSV Low-voltage electrical installations - Part 4-44: Protection for safety - Protection against voltage disturbances and electromagnetic disturbances
    IEC 60099-1:1991+AMD1:1999 CSV Surge arresters - Part 1: Non-linear resistor type gapped surge arresters for a.c. systems
    IEC 60947-1:2007+AMD1:2010+AMD2:2014 CSV Low-voltage switchgear and controlgear - Part 1: General rules
    IEC 60695-11-10:2013 Fire hazard testing - Part 11-10: Test flames - 50 W horizontal and vertical flame test methods
    IEC 60050-826:2004 International Electrotechnical Vocabulary (IEV) - Part 826: Electrical installations
    ISO 7000:2014 Graphical symbols for use on equipment Registered symbols
    IEC 61140:2016 Protection against electric shock - Common aspects for installation and equipment
    IEC 60695-2-10:2013 Fire hazard testing - Part 2-10: Glowing/hot-wire based test methods - Glow-wire apparatus and common test procedure
    IEC 60445:2017 Basic and safety principles for man-machine interface, marking and identification - Identification of equipment terminals, conductor terminations and conductors
    IEC 60664-1:2007 Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective