• IEC 62439-4:2010

    Current The latest, up-to-date edition.

    Industrial communication networks - High availability automation networks - Part 4: Cross-network Redundancy Protocol (CRP)

    Available format(s):  Hardcopy, PDF, PDF 3 Users, PDF 5 Users, PDF 9 Users

    Language(s): 

    Published date:  26-02-2010

    Publisher:  International Electrotechnical Committee

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    FOREWORD
    INTRODUCTION
    1 Scope
    2 Normative references
    3 Terms, definitions, abbreviations, acronyms, and
      conventions
    4 CRP overview
    5 CRP nodes
    6 CRP LAN topology
    7 CRP key components
    8 CRP protocol
    9 CRP Management Information Base (MIB)
    Bibliography

    Abstract - (Show below) - (Hide below)

    IEC 62439-4:2010 is applicable to high-availability automation networks based on the ISO/IEC 8802-3 (IEEE 802.3) (Ethernet) technology. It specifies a redundancy protocol that is based on the duplication of the network, the redundancy protocol being executed within the end nodes, as opposed to a redundancy protocol built in the switches. The switchover decision is taken in each node individually. The cross-network connection capability enables single attached end nodes to be connected on either of the two networks. It cancels and replaces IEC 62439 published in 2008 and constitutes a technical revision. It includes the following significant technical changes with respect to IEC 62439 (2008):
    - adding a calculation method for RSTP (rapid spanning tree protocol, IEEE 802.1Q),
    - adding two new redundancy protocols: HSR (High-availability Seamless Redundancy) and DRP (Distributed Redundancy Protocol),
    - moving former Clauses 1 to 4 (introduction, definitions, general aspects) and the Annexes (taxonomy, availability calculation) to IEC 62439-1, which serves now as a base for the other documents,
    - moving Clause 5 (MRP) to IEC 62439-2 with minor editorial changes,
    - moving Clause 6 (PRP) was to IEC 62439-3 with minor editorial changes,
    - moving Clause 7 (CRP) was to IEC 62439-4 with minor editorial changes, and
    - moving Clause 8 (BRP) was to IEC 62439-5 with minor editorial changes,
    - adding a method to calculate the maximum recovery time of RSTP in a restricted configuration (ring) to IEC 62439-1 as Clause 8,
    - adding specifications of the HSR (High-availability Seamless Redundancy) protocol, which shares the principles of PRP to IEC 62439-3 as Clause 5, and
    - introducing the DRP protocol as IEC 62439-6.

    This publication is to be read in conjunction with IEC 62439-1:2010.

    General Product Information - (Show below) - (Hide below)

    Committee TC 65/SC 65C
    Development Note Supersedes IEC 62439. To be read in conjunction with IEC 62439-1. (03/2010) A Bilingual edition has been published. (12/2012) Stability Date: 2020. (09/2017)
    Document Type Standard
    Publisher International Electrotechnical Committee
    Status Current
    Supersedes

    Standards Referenced By This Book - (Show below) - (Hide below)

    BS EN 62439-5:2010 Industrial communication networks. High availability automation networks Beacon redundancy protocol (BRP)
    BS EN 62439-6:2010 Industrial communication networks. High availability automation networks Distributed redundancy protocol (DRP)
    EN 61162-460:2015 Maritime navigation and radiocommunication equipment and systems - Digital interfaces - Part 460: Multiple talkers and multiple listeners - Ethernet interconnection - Safety and security
    EN 62439-6:2010 Industrial communication networks - High availability automation networks - Part 6: Distributed Redundancy Protocol (DRP)
    I.S. EN 62439-6:2010 INDUSTRIAL COMMUNICATION NETWORKS - HIGH AVAILABILITY AUTOMATION NETWORKS - PART 6: DISTRIBUTED REDUNDANCY PROTOCOL (DRP)
    BS EN 62439-1 : 2010 INDUSTRIAL COMMUNICATION NETWORKS - HIGH AVAILABILITY AUTOMATION NETWORKS - PART 1: GENERAL CONCEPTS AND CALCULATION METHODS
    14/30297254 DC : 0 BS EN 62439-X - INDUSTRIAL COMMUNICATION NETWORKS - HIGH AVAILABILITY AUTOMATION NETWORKS
    I.S. EN 62439-5:2010 INDUSTRIAL COMMUNICATION NETWORKS - HIGH AVAILABILITY AUTOMATION NETWORKS - PART 5: BEACON REDUNDANCY PROTOCOL (BRP)
    16/30346333 DC : 0 BS EN 61162-460 - MARITIME NAVIGATION AND RADIOCOMMUNICATION EQUIPMENT AND SYSTEMS -DIGITAL INTERFACES - PART 460: MULTIPLE TALKERS AND MULTIPLE LISTENERS - ETHERNET INTERCONNECTION - SAFETY AND SECURITY
    I.S. EN 61162-460:2015 MARITIME NAVIGATION AND RADIOCOMMUNICATION EQUIPMENT AND SYSTEMS - DIGITAL INTERFACES - PART 460: MULTIPLE TALKERS AND MULTIPLE LISTENERS - ETHERNET INTERCONNECTION - SAFETY AND SECURITY
    I.S. EN IEC 62439-5:2018 INDUSTRIAL COMMUNICATION NETWORKS - HIGH AVAILABILITY AUTOMATION NETWORKS - PART 5: BEACON REDUNDANCY PROTOCOL (BRP)
    EN IEC 62439-5:2018 Industrial communication networks - High availability automation networks - Part 5: Beacon Redundancy Protocol (BRP)
    IEC 62439-1:2010+AMD1:2012+AMD2:2016 CSV Industrial communication networks - High availability automation networks - Part 1: General concepts and calculation methods
    EN 62439-1:2010/A2:2017 INDUSTRIAL COMMUNICATION NETWORKS - HIGH AVAILABILITY AUTOMATION NETWORKS - PART 1: GENERAL CONCEPTS AND CALCULATION METHODS (IEC 62439-1:2010/A2:2016)
    BS EN 61162-460:2015 Maritime navigation and radiocommunication equipment and systems. Digital interfaces Multiple talkers and multiple listeners. Ethernet interconnection. Safety and security
    CEI EN 62439-2 : 2011 INDUSTRIAL COMMUNICATION NETWORKS - HIGH AVAILABILITY AUTOMATION NETWORKS - PART 2: MEDIA REDUNDANCY PROTOCOL (MRP)
    I.S. EN 62439-1:2010 INDUSTRIAL COMMUNICATION NETWORKS - HIGH AVAILABILITY AUTOMATION NETWORKS - PART 1: GENERAL CONCEPTS AND CALCULATION METHODS
    IEC 62439-5:2016 Industrial communication networks - High availability automation networks - Part 5: Beacon Redundancy Protocol (BRP)
    IEC 62439-6:2010 Industrial communication networks - High availability automation networks - Part 6: Distributed Redundancy Protocol (DRP)
    BS EN 62439-3:2012 Industrial communication networks. High availability automation networks Parallel Redundancy Protocol (PRP) and High-availability Seamless Redundancy (HSR)
    CEI EN 62439-5 : 2011 INDUSTRIAL COMMUNICATION NETWORKS - HIGH AVAILABILITY AUTOMATION NETWORKS - PART 5: BEACON REDUNDANCY PROTOCOL (BRP)

    Standards Referencing This Book - (Show below) - (Hide below)

    IEC 62439-3:2016 Industrial communication networks - High availability automation networks - Part 3: Parallel Redundancy Protocol (PRP) and High-availability Seamless Redundancy (HSR)
    ISO/IEC 8802-3:2000 Information technology Telecommunications and information exchange between systems Local and metropolitan area networks Specific requirements Part 3: Carrier sense multiple access with collision detection (CSMA/CD) access method and physical layer specifications
    IEC 62439-5:2016 Industrial communication networks - High availability automation networks - Part 5: Beacon Redundancy Protocol (BRP)
    IEC 62439-1:2010+AMD1:2012+AMD2:2016 CSV Industrial communication networks - High availability automation networks - Part 1: General concepts and calculation methods
    IEC 62439-6:2010 Industrial communication networks - High availability automation networks - Part 6: Distributed Redundancy Protocol (DRP)
    IEC 62439-2:2016 Industrial communication networks - High availability automation networks - Part 2: Media Redundancy Protocol (MRP)
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective