• PREN 14791 : DRAFT 2014

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    STATIONARY SOURCE EMISSIONS - DETERMINATION OF MASS CONCENTRATION OF SULPHUR OXIDES - STANDARD REFERENCE METHOD

    Available format(s): 

    Superseded date:  01-01-2017

    Language(s): 

    Published date:  03-11-2014

    Publisher:  Comite Europeen de Normalisation

    Pure ENs are not available for sale, please purchase a suitable national adoption

    Sorry this product is not available in your region.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    Foreword
    1 Scope
    2 Normative references
    3 Terms and definitions
    4 Symbols and abbreviated terms
    5 Measuring principle
    6 Description of measuring equipment
    7 Performance characteristics of the SRM
    8 Sampling procedure
    9 Analytical procedure
    10 Expression of results
    11 Equivalence of Thorin and ion chromatography methods
    12 Equivalence with an alternative method
    13 Test report
    Annex A (informative) - Type of sampling equipment
    Annex B (informative) - Examples of absorbers
    Annex C (informative) - Evaluation of the method in the field
    Annex D (informative) - Example of assessment of compliance or
            reference method for SO[2] with requirements on emission
            measurements
    Annex E (informative) - Test of equivalency of Thorin method and
            ion chromatography
    Annex F (informative) - Calculation of the uncertainty associated
            with a concentration expressed on dry gas and at a oxygen
            reference concentration
    Annex G (informative) - Significant technical changes
    Bibliography

    Abstract - (Show below) - (Hide below)

    Defines the standard reference method (SRM) for the determination of the sulphuric oxide SO[2] in flue gases emitted to the atmosphere from ducts and stacks.

    General Product Information - (Show below) - (Hide below)

    Comment Closes On
    Committee TC 264
    Document Type Draft
    Publisher Comite Europeen de Normalisation
    Status Superseded
    Superseded By

    Standards Referenced By This Book - (Show below) - (Hide below)

    PREN 14790 : DRAFT 2014 STATIONARY SOURCE EMISSIONS - DETERMINATION OF THE WATER VAPOUR IN DUCTS - STANDARD REFERENCE METHOD
    VDI 3899 Blatt 1:2016-05 Emission control - Landfill gas - Utilisation and treatment of landfill gas
    VDI 3896:2015-10 Emission control - Preparation of biogas to natural gas quality
    VDI 2578:2017-05 Emission control - Glassworks
    14/30293551 DC : 0 BS EN 14790 - STATIONARY SOURCE EMISSIONS - DETERMINATION OF THE WATER VAPOUR IN DUCTS - STANDARD REFERENCE METHOD
    15/30318313 DC : 0 BS EN 15267-4 - AIR QUALITY - CERTIFICATION OF AUTOMATED MEASURING SYSTEMS - PART 4: PERFORMANCE CRITERIA AND TEST PROCEDURES FOR AUTOMATED MEASURING SYSTEMS FOR PERIODIC MEASUREMENTS OF EMISSIONS FROM STATIONARY SOURCE

    Standards Referencing This Book - (Show below) - (Hide below)

    CEN/TS 15675:2007 Air quality - Measurement of stationary source emissions - Application of EN ISO/IEC 17025:2005 to periodic measurements
    ISO 14956:2002 Air quality Evaluation of the suitability of a measurement procedure by comparison with a required measurement uncertainty
    ISO 5725-6:1994 Accuracy (trueness and precision) of measurement methods and results — Part 6: Use in practice of accuracy values
    EN 15259:2007 Air quality - Measurement of stationary source emissions - Requirements for measurement sections and sites and for the measurement objective, plan and report
    ISO/IEC Guide 99:2007 International vocabulary of metrology Basic and general concepts and associated terms (VIM)
    EN ISO 14956 : 2002 AIR QUALITY - EVALUATION OF THE SUITABILITY OF A MEASUREMENT PROCEDURE BY COMPARISON WITH A REQUIRED MEASUREMENT UNCERTAINTY
    ISO 5725-2:1994 Accuracy (trueness and precision) of measurement methods and results Part 2: Basic method for the determination of repeatability and reproducibility of a standard measurement method
    PREN 14793 : DRAFT 2014 STATIONARY SOURCE EMISSIONS - DEMONSTRATION OF EQUIVALENCE OF AN ALTERNATIVE METHOD WITH A REFERENCE METHOD
    ISO/IEC Guide 98-3:2008 Uncertainty of measurement — Part 3: Guide to the expression of uncertainty in measurement (GUM:1995)