• S.R. CLC/TS 61643-22:2016

    Current The latest, up-to-date edition.

    LOW-VOLTAGE SURGE PROTECTIVE DEVICES - PART 22: SURGE PROTECTIVE DEVICES CONNECTED TO TELECOMMUNICATIONS AND SIGNALLING NETWORKS - SELECTION AND APPLICATION PRINCIPLES

    Available format(s):  Hardcopy, PDF

    Language(s):  English

    Published date:  01-01-2016

    Publisher:  National Standards Authority of Ireland

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    National Foreword
    FOREWORD
    INTRODUCTION
    1 Scope
    2 Normative references
    3 Terms, definitions and abbreviations
    4 Description of technologies
    5 Parameters for selection of SPDs and appropriate tests
      from IEC 61643-21
    6 Risk management
    7 Application of SPDs
    8 Multiservice surge protective devices
    9 Coordination of SPDs/ITE
    Annex A (informative) - Voltage-limiting components
    Annex B (informative) - Current-limiting components
    Annex C (informative) - Risk management
    Annex D (informative) - Transmission characteristics related
            to IT systems
    Annex E (informative) - Coordination of SPDs/ITE
    Annex F (informative) - Protection of Ethernet systems
    Annex G (informative) - EMC impact of SPDs
    Annex H (informative) - Definition of internal port (Source:
            ITU-T K.44)
    Annex I (informative) - Maintenance of SPDs for Information
            Technology
    Annex J (informative) - Earth potential rise (EPR)
    Annex K (informative) - References and examples of risk
            management based on IEC 62305-2
    Bibliography

    Abstract - (Show below) - (Hide below)

    Explains the principles for the selection, operation, location and coordination of SPDs connected to telecommunication and signalling networks with nominal system voltages up to 1000 V r.m.s. a.c. and 1500 V d.c.

    General Product Information - (Show below) - (Hide below)

    Development Note Supersedes I.S. CLC TS 61643-22. (04/2016) For CENELEC adoptions of IEC publications, please check www.iec.ch to be sure that you have any corrigenda that may apply. (01/2017)
    Document Type Standard
    Publisher National Standards Authority of Ireland
    Status Current
    Supersedes

    Standards Referencing This Book - (Show below) - (Hide below)

    TS 101 524-2 : 1.1.1 TRANSMISSION AND MULTIPLEXING (TM); ACCESS TRANSMISSION SYSTEM ON METALLIC ACCESS CABLES; SYMMETRICAL SINGLE PAIR HIGH BIT RATE DIGITAL SUBSCRIBER LINE (SDSL); PART 2: TRANSCEIVER REQUIREMENTS
    IEC 61643-321:2001 Components for low-voltage surge protective devices - Part 321: Specifications for avalanche breakdown diode (ABD)
    TS 101 388 : 1.4.1 ACCESS TERMINALS TRANSMISSION AND MULTIPLEXING (ATTM); ACCESS TRANSMISSION SYSTEMS ON METALLIC ACCESS CABLES; ASYMMETRIC DIGITAL SUBSCRIBER LINE (ADSL) - EUROPEAN SPECIFIC REQUIREMENTS
    IEC 61643-12:2008 Low-voltage surge protective devices - Part 12: Surge protective devices connected to low-voltage power distribution systems - Selection and application principles
    IEEE 802.3-2012 IEEE Standard for Ethernet
    IEC 60364-5-51:2005 Electrical installations of buildings - Part 5-51: Selection and erection of electrical equipment - Common rules
    IEC 61000-6-1 : 3.0 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-1: GENERIC STANDARDS - IMMUNITY STANDARD FOR RESIDENTIAL, COMMERCIAL AND LIGHT-INDUSTRIAL ENVIRONMENTS
    ISO/IEC 11801:2002 Information technology Generic cabling for customer premises
    TS 101 524 : 1.5.1 ACCESS, TERMINALS, TRANSMISSION AND MULTIPLEXING (ATTM); ACCESS TRANSMISSION SYSTEM ON METALLIC ACCESS CABLES; SYMMETRIC SINGLE PAIR HIGH BITRATE DIGITAL SUBSCRIBER LINE (SDSL)
    IEC 60728-2:2010 Cable networks for television signals, sound signals and interactive services - Part 2: Electromagnetic compatibility for equipment
    IEC 61643-21:2000+AMD1:2008+AMD2:2012 CSV Low voltage surge protective devices - Part 21: Surge protective devices connected to telecommunications and signalling networks - Performance requirements and testing methods
    IEC 61643-311:2013 Components for low-voltage surge protective devices - Part 311: Performance requirements and test circuits for gas discharge tubes (GDT)
    TS 101 135 : 1.5.3 TRANSMISSION AND MULTIPLEXING (TM); HIGH BIT-RATE DIGITAL SUBSCRIBER LINE (HDSL) TRANSMISSION SYSTEMS ON METALLIC LOCAL LINES; HDSL CORE SPECIFICATION AND APPLICATIONS FOR COMBINED ISDN-BA AND 2 048 KBIT/S TRANSMISSION
    IEC 62305-1:2010 Protection against lightning - Part 1: General principles
    EN 50173-1:2011 Information technology - Generic cabling systems - Part 1: General requirements
    IEEE C62.50-2012 IEEE Standard for Performance Criteria and Test Methods for Plug-in (Portable) Multiservice (Multiport) Surge-Protective Devices for Equipment Connected to a 120 V/240 V Single Phase Power Service and Metallic Conductive Communication Line(s)
    IEC 61643-11:2011 Low-voltage surge protective devices - Part 11: Surge protective devices connected to low-voltage power systems - Requirements and test methods
    IEC 61000-2-2:2002+AMD1:2017 CSV Electromagnetic compatibility (EMC) - Part 2-2: Environment - Compatibility levels for low-frequency conducted disturbances and signalling in public low-voltage power supply systems
    IEC 61000-6-1:2016 Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity standard for residential, commercial and light-industrial environments
    EG 201 280 : 1.1.1 DRAFT ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MATTERS (ERM) - RESISTIBILITY REQUIREMENTS FOR EQUIPMENT HAVING (A) TELECOMMUNICATION PORT(S)
    ISO/IEC 8802-5 : 1998 INFORMATION TECHNOLOGY - TELECOMMUNICATIONS AND INFORMATION EXCHANGE BETWEEN SYSTEMS - LOCAL AND METROPOLITAN AREA NETWORKS - SPECIFIC REQUIREMENTS - PART 5: TOKEN RING ACCESS METHOD AND PHYSICAL LAYER SPECIFICATIONS
    EN 50468:2009 Resistibility requirements to overvoltages and overcurrents due to lightning for equipment having telecommunication ports
    IEC 60721-3-3:1994+AMD1:1995+AMD2:1996 CSV Classification of environmental conditions - Part 3-3: Classification of groups of environmental parameters and their severities - Stationary use at weatherprotected locations
    TS 102 080 : 1.4.1 TRANSMISSION AND MULTIPLEXING (TM); INTEGRATED SERVICES DIGITAL NETWORK (ISDN) BASIC RATE ACCESS; DIGITAL TRANSMISSION SYSTEM ON METALLIC LOCAL LINES
    IEC 62305-4:2010 Protection against lightning - Part 4: Electrical and electronic systems within structures
    IEC 61643-341:2001 Components for low-voltage surge protective devices - Part 341: Specification for thyristor surge suppressors (TSS)
    EN 50083-1:1993/A2:1997 CABLE NETWORKS FOR TELEVISION SIGNALS, SOUND SIGNALS AND INTERACTIVE SERVICES - PART 1: SAFETY REQUIREMENTS
    IEC 61643-331:2003 Components for low-voltage surge protective devices - Part 331: Specification for metal oxide varistors (MOV)
    TS 101 524-1 : 1.1.1 TRANSMISSION AND MULTIPLEXING (TM); ACCESS TRANSMISSION SYSTEM ON METALLIC ACCESS CABLES; SYMMETRICAL SINGLE PAIR HIGH BIT RATE DIGITAL SUBSCRIBER LINE (SDSL); PART 1: FUNCTIONAL REQUIREMENTS
    IEC 62305-2:2010 Protection against lightning - Part 2: Risk management
    TS 101 270-2 : 1.2.1 TRANSMISSION AND MULTIPLEXING (TM); ACCESS TRANSMISSION SYSTEMS ON METALLIC ACCESS CABLES; VERY HIGH SPEED DIGITAL SUBSCRIBER LINE (VDSL); PART 2: TRANSCEIVER SPECIFICATION
    IEC 62305-3:2010 Protection against lightning - Part 3: Physical damage to structures and life hazard
    ISO Guide 73:2009 Risk management — Vocabulary
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective