    1 - AS 60146.1.2-2002 SEMICONDUCTOR CONVERTERS - GENERAL REQUIREMENTS AND LINE COMMUTATED CONVERTERS-APPLICATION GUIDE
    4 - PREFACE
    5 - CONTENTS
    11 - Section 1 - General
    11 - 1.1 Scope
    11 - 1.2 Application of semiconductor power converters
    11 - 1.2.1 Conversion equipment
    12 - 1.2.2 Supply source conditioning (active and reactive power)
    12 - 1.3 Equipment specification data
    12 - 1.3.1 Main items of the specification
    12 - 1.3.2 Additional information
    13 - 1.3.3 Unusual service conditions
    13 - 1.4 Converter transformers and reactors
    13 - 1.5 Calculation factors
    13 - 1.5.1 Voltage ratios
    14 - 1.5.2 Line side transformer current factor
    14 - 1.5.3 Valve-side transformer current factor
    14 - 1.5.4 Voltage regulation
    17 - 1.5.5 Magnetic circuit
    17 - 1.5.6 Power loss factor
    17 - 1.6 Parallel and series connections
    17 - 1.6.1 Parallel or series connection of valve devices
    17 - 1.6.2 Parallel or series connection of assemblies and equipment units
    18 - 1.7 Power factor
    18 - 1.7.1 General
    19 - 1.7.2 Symbols used in the determination of displacement factor
    20 - 1.7.3 Circle diagram for the approximation of the displacement factor ...
    20 - 1.7.4 Calculation of the displacement factor...
    22 - 1.7.5 Conversion factor
    23 - 1.8 Direct voltage regulation
    23 - 1.8.1 Inherent direct voltage regulation
    25 - 1.8.2 Direct voltage regulation due to a.c. system impedance
    28 - 1.8.3 Information to be exchanged between supplier and purchaser about direct voltage regulation of the converter
    28 - 1.9 Voltage limits for reliable commutation in inverter mode
    29 - 1.10 A.C. voltage waveform
    31 - Section 2 - Definitions
    31 - 2.1 Definitions related to converter faults
    31 - 2.1.1 Conduction through (shoot through) (IEV 551-05-58, modified)
    31 - 2.1.2 Firing failure (IEV 551-05-57, modified)
    31 - 2.1.3 Breakthrough (IEV 551-05-53, modified)
    31 - 2.1.4 Breakdown (IEV 551-05-59, modified)
    31 - 2.1.5 False firing (IEV 551-05-56, modified)
    31 - 2.1.6 Commutation failure (IEV 551-05-52, modified)
    31 - 2.2 Definitions related to converter generated transients
    31 - 2.2.1 D.C. side transients
    31 - 2.2.2 Commutation transients on the line (repetitive transients)
    33 - Section 3 - Application information
    33 - 3.1 Practical calculation of the operating parameters
    33 - 3.1.1 Assumptions
    33 - 3.1.2 Preliminary calculations
    34 - 3.1.3 Calculation of the operating conditions
    36 - 3.2 Supply system voltage change due to converter loads
    36 - 3.2.1 Fundamental voltage change
    37 - 3.2.2 Minimum RSC requirements for voltage change
    37 - 3.2.3 Converter transformer ratio
    38 - 3.2.4 Transformer rating
    39 - 3.3 Compensation of converter reactive power consumption
    39 - 3.3.1 Average reactive power consumption
    39 - 3.3.2 Required compensation of the average reactive power
    40 - 3.3.3 Voltage fluctuations with fixed reactive power compensation
    40 - 3.4 Direct voltage harmonic content
    41 - 3.5 Supply voltage distortion
    41 - 3.5.1 Commutation notches
    43 - 3.5.2 Operation of several converters on the same supply line
    44 - 3.6 Quantities on the line side
    44 - 3.6.1 R.M.S. value of the line current
    45 - 3.6.2 Harmonics on the line side, approximate method for 6-pulse converters
    46 - 3.6.3 Minimum RSC requirements for harmonic distortion
    47 - 3.6.4 Calculation of the harmonic current spectrum
    49 - 3.6.5 Estimated phase shift of the harmonic currents
    49 - 3.6.6 Addition of harmonic currents
    49 - 3.6.7 Peak and average harmonic spectrum
    49 - 3.6.8 Transformer phase shift
    50 - 3.6.9 Sequential gating, two 6-pulse converters
    50 - 3.7 Power factor compensation and harmonic distortion
    50 - 3.7.1 Resonant frequency
    50 - 3.7.2 Directly connected capacitor bank
    51 - 3.7.3 Estimation of the resonant frequency
    52 - 3.7.4 Detuning reactor
    53 - 3.7.5 Ripple control frequencies (Carrier frequencies)
    53 - 3.8 Other considerations
    53 - 3.8.1 Random control angle
    54 - 3.8.2 Sub-harmonic instability
    54 - 3.8.3 Harmonic filters
    54 - 3.8.4 Approximate capacitance of cables
    54 - 3.9 Calculation of d.c. short-circuit current of converters
    55 - 3.10 Guide-lines for the selection of the immunity class
    55 - 3.10.1 Converter immunity class
    55 - 3.10.2 Selection of the immunity class
    59 - Section 4 - Test requirements
    59 - 4.1 Guidance on power loss evaluation by short-circuit test
    59 - 4.1.1 Single-phase connections
    59 - 4.1.2 Polyphase double-way connections
    59 - 4.1.3 Polyphase single-way connections
    59 - 4.2 Procedure for evaluation of power losses by short-circuit method
    60 - 4.3 Test methods
    60 - 4.3.1 Method A1
    61 - 4.3.2 Method B
    61 - 4.3.3 Method C
    61 - 4.3.4 Method D
    63 - 4.3.5 Method E
    64 - 4.3.6 Method A2
    65 - Section 5 - Performance requirements
    65 - 5.1 Presentation of rated peak load current values
    66 - 5.2 Definitions and letter symbols related to virtual junction temperature
    66 - 5.2.1 Letter symbols
    67 - 5.2.2 Thermal resistance Rth
    67 - 5.2.3 Transient thermal impedance Zth
    67 - 5.2.4 Virtual junction temperature...
    67 - 5.3 Determination of peak load capability through calculation of the virtual junction temperature
    68 - 5.3.1 Approximation of the shape of power pulses applied to the semiconductor device
    69 - 5.3.2 The superposition method for calculation of temperature
    69 - 5.3.3 Calculation of the virtual junction temperature for continuous load
    71 - 5.3.4 Calculation of the virtual junction temperature for cyclic loads
    72 - 5.3.5 Calculation of virtual junction temperature for a few typical applications
    72 - 5.4 Circuit operating conditions affecting the voltage applied across converter elements
    74 - Section 6 - Converter operation
    74 - 6.1 Stabilization
    74 - 6.2 Static properties
    74 - 6.3 Dynamic properties of the control system
    74 - 6.4 Mode of operation of single and double converters
    74 - 6.4.1 Single converter connection
    76 - 6.4.2 Double converter connections and limits for rectifier and inverter operation
    77 - 6.5 Transition current
    78 - 6.6 Suppression of direct current circulation in double converter connections
    78 - 6.6.1 Limitation of delay angles
    78 - 6.6.2 Controlled circulating current
    78 - 6.6.3 Blocking of trigger pulses
    79 - 6.7 Principle of operation for reversible converters for control of d.c. motors
    79 - 6.7.1 Motor field reversal
    79 - 6.7.2 Motor armature reversal by reversing switch
    79 - 6.7.3 Double converter connection to motor armature
    81 - Section 7 - Converter faults
    81 - 7.1 General
    81 - 7.2 Fault finding
    82 - Annex A - Bibliography

    Abstract - (Show below) - (Hide below)

    Gives guidance on variations to AS 60146.1.1-2002 to enable that Standard to be extended in a controlled form for special cases. This Standard has been reproduced from and is technically identical to IEC 60146-1-2:1991.

    Scope - (Show below) - (Hide below)

    This report gives guidance on variations to the specifications in IEC 146-1-1 to enable the specification to be extended in a controlled form for special cases. Background information is also given on technical points which should facilitate the use of IEC 146-1-1.This report primarily covers line commutated converters and is not in itself a specification, except as regards certain auxiliary components, in so far as existing standards may not provide the necessary data.

    General Product Information - (Show below) - (Hide below)

    Committee EL-027
    Document Type Standard
    Product Note This standard has been reconfirmed in Australia in 2013 and remains current in New Zealand. Reconfirmation Notice 13-01-2014
    Publisher Standards Australia
    Status Current
    Supersedes

    History - (Show below) - (Hide below)

    First published as part of AS 1955.1-1977.Revised and redesignated in part as AS 60146.1.2-2002.Reconfirmed 2013. First published as part of AS 1955.1-1977. Revised and redesignated in part as AS 60146.1.2-2002.

    Standards Referenced By This Book - (Show below) - (Hide below)

    AS 1013-1971 Shunt capacitors for connection to power frequency systems
    AS 1852.551-1983 International electrotechnical vocabulary - Power electronics

    Standards Referencing This Book - (Show below) - (Hide below)

    AS 62040.3-2002 Uninterruptible power systems (UPS) Method of specifying the performance and test requirements
    AS 60146.1.3-2002 Semiconductor converters General requirements and line commutated converters - Transformers and reactors
    AS/NZS 3000:2007 Electrical installations (known as the Australian/New Zealand Wiring Rules)
    AS 61800.4-2007 Adjustable speed electrical power drive systems General requirements - Rating specifications for a.c. power drive systems above 1000 V a.c. and not exceeding 35 kV (Reconfirmed 2016)
    AS 61800.1-2007 Adjustable speed electrical power drive systems General requirements - Rating specifications for low voltage adjustable speed d.c. power drive systems (Reconfirmed 2016)
    AS 61800.2-2004 Adjustable speed electrical power drive systems General requirements - Rating specifications for low voltage adjustable frequency a.c. power drive systems
    AS/NZS 3000:2018 (Unamended Hardcopy + Amendments) Electrical installations (known as the Australian/New Zealand Wiring Rules)
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective