• BS 2562:1979

    Current The latest, up-to-date edition.

    Specification for cable boxes for transformers and reactors

    Available format(s):  Hardcopy, PDF

    Language(s):  English

    Published date:  31-12-1979

    Publisher:  British Standards Institution

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    Foreword
    Cooperating organizations
    Specification
    Section one. General
    1. Scope
    2. References
    3. Definitions
    Section two. Performance and design requirements for
                 cable boxes
    4. Electrical requirements and clearances
    5. Electromagnetic considerations
    6. Provision for receiving cables
    7. General design requirements
    Section three. Tests for cable boxes
    8. Type tests
    9. Routine tests
    Section four. Requirements for a range of single-pole,
                  three-pole and four-pole cable boxes
    10. Basis of range of boxes specified
    11. Bushings
    12. Cast resin bushing assemblies
    13. Shell dimensions
    Appendices
    A. Information to be given with enquiry and order
    B. Wiping glands for metallic sheathed cables
    Tables
    1. Clearances
    2. Terminal stems and nuts
    3. Cable box ratings, shell dimensions and general
         particulars for filled boxes with porcelain
         bushings; single-pole boxes 1.1 kV to 12 kV
    4. Cable box ratings, shell dimensions and general
         particulars for filled boxes with porcelain
         bushings; three-pole boxes 1.1 kV to 12 kV
    5. Cable box ratings, shell dimensions and general
         particulars for filled boxes with porcelain
         bushings; four-pole boxes 1.1 kV to 12 kV
    6. Cable box ratings, shell dimensions and general
         particulars for filled boxes with porcelain
         bushings; single-pole and three-pole boxes 24 kV
         and 36 kV
    7. Cable box ratings, shell dimensions and general
         particulars for filled boxes with cast resin
         bushing assemblies; four-pole boxes 1.1 kV
    8. Cable box ratings, shell dimensions and general
         particulars for unfilled boxes with porcelain
         bushings; single-pole boxes 1.1 kV
    9. Cable box ratings, shell dimensions and general
         particulars for unfilled boxes with porcelain
         bushings; three-pole boxes 1.1 kV and 3.6 kV
    10. Cable box ratings, shell dimensions and general
         particulars for unfilled boxes with porcelain
         bushings; four-pole boxes 1.1 kV and 3.6 kV
    11. Cable box ratings, shell dimensions and general
         particulars for unfilled boxes with cast resin
         bushing assemblies; four-pole boxes 1.1 kV
    12. Gland sizes
    Figures
    1. Standard porcelains
    2. Bushing clamps
    3. Assembly of 250 A and 400 A porcelain bushings
         for use up to 12 kV rated voltage
    4. Assembly of 250 A and 400 A epoxide resin bushings
         for use up to 12 kV rated voltage
    5. Assembly of 800 A porcelain bushing for use up to
         12 kV rated voltage
    6. Assembly of 800 A epoxide resin bushing for use
         up to 12 kV rated voltage
    7. Assembly of 1600 A porcelain bushing for use up to
         12 kV rated voltage
    8. Assembly of 1600 A epoxide resin bushing for use up
         to 12 kV rated voltage
    9. Assembly of 2500 A porcelain bushing for use up to
         12 kV rated voltage
    10. Assembly of 2500 A epoxide resin bushing for use up
         to 12 kV rated voltage
    11. Assembly of 250 A porcelain bushing for use up to
         24 kV rated voltage
    12. Assembly of 525 A and 800 A porcelain bushings for
         use up to 24 kV rated voltage
    13. Assembly of 250 A porcelain bushing for use up to
         36 kV rated voltage
    14. Assembly of 800 A porcelain bushing for use up to
         36 kV rated voltage
    15. Assembly of 800 A condenser bushing for use up to
         36 kV rated voltage
    16. 800 A and 1400 A cast resin bushing assemblies
         for use up to 1.1 kV rated voltage
    17. Bushing mounting plates for single-pole boxes
         (for use up to 3.6 kV rated voltage)
    18. Bushing mounting plates for three-pole boxes
         (for use up to 3.6 kV rated voltage)
    19. Bushing mounting plates for four-pole boxes
         (for use up to 3.6 kV rated voltage)
    20. Copper based alloy bushing end caps, designations
         A, B, C and D
    21. Copper based alloy cable connectors and ferrules
    22. Copper based alloy bushing end caps, designations
         1 to 7
    23. Facings for single-pole boxes
    24. Facings for three-pole boxes
    25. Facings for four-pole boxes
    26. Typical arrangement of gland plate mounting for
         compound filled boxes
    27. Assembly of filling orifice
    28. Shell dimensions for filled boxes (for use up to
         12 kV rated voltage)
    29. Shell dimensions for filled boxes (for use at 24 kV
         and 36 kV rated voltage)
    30. Shell dimensions for unfilled boxes with cast resin
         bushing assemblies in accordance with figure 16
         for use up to 1.1 kV rated voltage and individual
         bushing assemblies for use up to 3.6 kV rated
         voltage
    31. Gland size X
    32. Gland size Y
    33. Gland size Z
    34. Typical arrangement of uninsulated gland assembly
         types A and B
    35. Moulded insulator for gland assembly types C2 and
         D2
    36. Typical arrangement of insulated gland assembly
         (utilizing moulded insulator) types C2 and D2
    37. Insulation for gland assembly types C1, D1, E1
         and F1
    38. Typical arrangement of insulated gland assembly
         (utilizing insulating plate and bushes) types C1
         and D1
    39. Island layers for gland assembly types E1 and F1
    40. Typical arrangement of insulated gland assembly with
         island layer (utilizing insulating plates and
         bushes) types E1 and F1
    41. Armour clamps

    Abstract - (Show below) - (Hide below)

    Specifies envelope and fixing dimensions and dimensions of certain components. For voltages up to 36 kV and currents up to 2500 A. Requirements for boxes in which the cores of cables terminate and are connected to terminals. For paper or extruded insulated cables with copper or aluminium conductors and lead or aluminium sheaths.

    Scope - (Show below) - (Hide below)

    This British Standard specifies requirements for cable boxes in which the cores of cables terminate within the box and are connected to terminals fixed therein.

    The boxes are intended for the termination of impregnated-paper-insulated solid-type lead or aluminium sheathed cables having copper or aluminium conductors and for the termination of extruded insulated and sheathed unarmoured cables having copper or aluminium conductors.

    The boxes are suitable for operating indoors or outdoors under conditions of ambient temperature, loading, altitude, etc., envisaged by BS 171.

    The standard box is arranged for cables approaching vertically from below and is not bi-directional. Where cables approach vertically from above, alternative parts are required (see Figure 28).

    Details of the range of boxes are given in Table 3 to Table 11.

    The objectives of this standard are to specify standard envelope dimensions and fixing dimensions of cable boxes to achieve interchangeability whatever type of filling medium is to be used, and also to specify dimensions of components, e.g. bushings, glands, for interchangeability of such parts.

    The boxes are suitable for rated voltages up to 36 kV and currents up to 2 500 A.

    This standard does not purport to specify complete details of design and construction but some observations on these aspects are given in clause 7.

    NOTE This standard does not apply to boxes where the cable cores pass through to the transformer without a joint or are joined to cable tails in the box by sleeves or thimbles.

    Section 2 and 3 deal with design principles, general considerations and tests for a range of cable boxes up to and including 36 kV rated voltage.

    Section 4 specifies the essential dimensions and component details for the range of cable boxes.

    Appendix A lists the information to be given with enquiry and order. Appendix B specifies wiping glands for metallic sheathed cables.

    General Product Information - (Show below) - (Hide below)

    Committee PEL/14
    Development Note Supersedes 74/28844 DC, BS 2562-1(1955) and BS 2562-2(1959) (06/2005) Reviewed and confirmed by BSI, August 2012. (07/2012)
    Document Type Standard
    Publisher British Standards Institution
    Status Current
    Supersedes

    Standards Referenced By This Book - (Show below) - (Hide below)

    BS 3399:1961 Specification for transformers for use in ships
    BS 6436:1984 Specification for ground mounted distribution transformers for cable box or unit substation connection
    BS 6435:1984 Specification for unfilled enclosures for the dry termination of HV cables for transformers and reactors
    BS 7354:1990 Code of practice for design of high-voltage open-terminal stations
    BS 171:1970 Specification for power transformers

    Standards Referencing This Book - (Show below) - (Hide below)

    BS 3692:1967 Specification for ISO metric precision hexagon bolts, screws and nuts. Metric units
    BS 223(1956) : PD 2945 BUSHINGS FOR ALTERNATING VOLTAGES ABOVE 1000 V
    BS 3816:1964 Specification for cast epoxide resin insulating material for electrical applications at power frequencies
    BS 171:1970 Specification for power transformers
    BS 5622-1:1979 Guide for insulation co-ordination Terms, definitions, principles and rules
    BS 3643(1963) : LATEST
    BS 381C:1964 Colours for specific purposes
    BS 6121:1973 Specification for mechanical cable glands for elastomer and plastics insulated cables
    BS 1872:1964 Electroplated coatings of tin
    BS 6346:1969 Specification for PVC-insulated cables for electricity supply
    BS 923:1972 Guide on high-voltage testing techniques.
    BS 6480(1969) : LATEST
    BS 771:1959 Phenolic moulding materials.
    BS 1858:1973 Specification for bitumen-based filling compounds for electrical purposes
    BS 91:1973 Specification for electric cable soldering sockets
    BS 4320:1968 Specification for metal washers for general engineering purposes. Metric series
    BS 4963:1973 Specification for tests on hollow insulators for use in high voltage electrical equipment