• BS 5345-7:1979

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    Code of practice for selection, installation and maintenance of electrical apparatus for use in potentially explosive atmospheres (other than mining applications or explosive processing and manufacture) Installation and maintenance requirements for electrical apparatus with type of protection N

    Available format(s):  Hardcopy, PDF

    Superseded date:  15-01-2000

    Language(s):  English

    Published date:  30-11-1979

    Publisher:  British Standards Institution

    Add To Cart

    Abstract - (Show below) - (Hide below)

    Provides guidance on the safe use of electrical apparatus in Zone 2 hazardous areas and includes an inspection schedule for planned maintenance.

    General Product Information - (Show below) - (Hide below)

    Committee EXL/31/3
    Development Note BS 5345 REPLACES CP 1003 AND SHOULD BE USED FOR ALL NEW INSTALLATIONS. CP 1003 WILL BE RETAINED TEMPORARILY AS A REFERENCE GUIDE FOR THE EXISTING PLANTS INSTALLED ACCORDING TO THE EARLIER CODE.
    Document Type Standard
    Publisher British Standards Institution
    Status Superseded
    Superseded By

    Standards Referenced By This Book - (Show below) - (Hide below)

    I.S. 3216-2:1989 CODE OF PRACTICE FOR THE BULK STORAGE OF LIQUEFIED PETROLEUM GAS
    ISA 92.04.01-1 : 2007 PERFORMANCE REQUIREMENTS FOR INSTRUMENTS USED TO DETECT OXYGEN-DEFICIENT/OXYGEN-ENRICHED ATMOSPHERES
    BS 5345-1:1989 Code of practice for selection, installation and maintenance of electrical apparatus for use in potentially explosive atmospheres (other than mining applications or explosive processing and manufacture) General recommendations
    BS 5908:1990 Code of practice for fire precautions in the chemical and allied industries
    BS 5000-16:1997 Rotating electrical machines of particular types or for particular applications Rotating electrical machines with type of protection \'N\'
    BS 6121-5:1993 Mechanical cable glands Code of practice for selection, installation and inspection of cable glands used in electrical installations
    BS 6701:1994 Code of practice for installation of apparatus intended for connection to certain telecommunication systems
    BS 466:1984 Specification for power driven overhead travelling cranes, semi-goliath and goliath cranes for general use
    BS 5908:1980 Code of practice for fire precautions in chemical plant
    BS 7117-2:1991 Metering pumps and dispensers to be installed at filling stations and used to dispense liquid fuel Guide to installation
    BS 6739:1986 Code of practice for instrumentation in process control systems: installation design and practice
    BS 7117-3:1991 Metering pumps and dispensers to be installed at filling stations and used to dispense liquid fuel Guide to maintenance after installation
    BS 6941:1988 Specification for electrical apparatus for explosive atmospheres with type of protection N
    BS 4163:2000 HEALTH AND SAFETY FOR DESIGN AND TECHNOLOGY IN SCHOOLS AND SIMILAR ESTABLISHMENTS - CODE OF PRACTICE

    Standards Referencing This Book - (Show below) - (Hide below)

    BS CP1003-1(1964) : AMD 5073 ELECTRICAL APPARATUS & ASSOCIATED EQUIPMENT FOR USE IN EXPLOSIVE ATMOSPHERES OF GAS OR VAPOUR OTHER THAN MINING APPLICATIONS - CHOICE, INSTALL & MAINTENANCE OF FLAMEPROOF & INTRINSICALLY SAFE EQ
    BS CP1003-3(1967) : AMD 5075 ELECTRICAL APPARATUS & ASSOCIATED EQUIPMENT FOR USE IN EXPLOSIVE ATMOSPHERES OF GAS OR VAPOUR OTHER THAN MINING APPLICATIONS - DIVISION 2 AREAS
    BS 5345-3:1979 Code of practice for selection, installation and maintenance of electrical apparatus for use in potentially explosive atmospheres (other than mining applications or explosive processing and manufacture) Installation and maintenance requirements for electrical apparatus with type of protection \'d\'. Flameproof enclosure
    BS 5345-8:1980 Code of practice for selection, installation and maintenance of electrical apparatus for use in potentially explosive atmospheres (other than mining applications or explosive processing and manufacture) Installation and maintenance requirements for electrical apparatus with type of protection \'s\'. Special protection
    BS 5345-4:1977 Code of practice for selection, installation and maintenance of electrical apparatus for use in potentially explosive atmospheres (other than mining applications or explosive processing and manufacture) Installation and maintenance requirements for electrical apparatus with type of protection \'i\'. Intrinsically safe electrical apparatus and systems
    BS 5345-2:1983 Code of practice for selection, installation and maintenance of electrical apparatus for use in potentially explosive atmospheres (other than mining applications or explosive processing and manufacture) Classification of hazardous areas
    BS 5345-6:1978 Code of practice for selection, installation and maintenance of electrical apparatus for use in potentially explosive atmospheres (other than mining applications or explosive processing and manufacture) Recommendations for type of protection \'e\'. Increased safety
    BS 5345-1:1989 Code of practice for selection, installation and maintenance of electrical apparatus for use in potentially explosive atmospheres (other than mining applications or explosive processing and manufacture) General recommendations
    BS CP1003-2(1966) : AMD 5074 METHODS OF MEETING THE EXPLOSION HAZARD OTHER THAN BY THE USE OF FLAMEPROOF OR INTRINSICALLY SAFE ELECTRICAL EQUIPMENT
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective