• BS 6400-3:2007

    Current The latest, up-to-date edition.

    Specification for installation, exchange, relocation and removal of gas meters with a maximum capacity not exceeding 6 m3/h Low and medium pressure (3rd family gases)

    Available format(s): 

    Language(s): 

    Published date:  30-11-2007

    Publisher:  British Standards Institution

    Sorry this product is not available in your region.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    Foreword
    1 Scope
    2 Normative references
    3 Terms and definitions
    4 Planning and exchange of information
    5 Competency
    6 Design
    7 Installation
    8 Gas tightness testing and purging
    9 Commissioning of the meter installation
    10 Notices
    11 Meter exchange and/or replacement of other gas fitting
    12 Meter relocation
    13 Meter removal
    14 Records
    15 Post installation checks
    Annexes
    Annex A (normative) - Sizing of meters
    Annex B (normative) - Operational pressure limits
    Bibliography

    Abstract - (Show below) - (Hide below)

    Describes requirements for the installation, exchange, relocation and removal of credit or prepayment diaphragm and ultrasonic gas meters with a maximum capacity not exceeding 6 m[3]/h.

    Scope - (Show below) - (Hide below)

    The standard specifies requirements for the installation, exchange, relocation and removal of credit or prepayment diaphragm and ultrasonic gas meters with a maximum capacity not exceeding 6 m3/h.

    NOTE 1 For the purposes of this standard, installation includes design, inspection and commissioning. It is recognized that each of these tasks can be performed by the same person.

    This part of BS 6400 is applicable to meter installations:

    1. supplied with 3rd family gases either:
      1. from low pressure service pipework with a maximum operating pressure not exceeding 75 mbar and a design maximum incidental pressure of 350 mbar; or
      2. from medium pressure service pipework with a maximum operating pressure exceeding 75 mbar but not exceeding 2 bar and a design maximum incidental pressure of 2.7 bar;
    2. only fitted downstream of the emergency control valve;
    3. that utilizes a meter regulator downstream of the emergency control valve;
    4. where all gas fittings subjected to medium pressure have been pre-assembled and where strength and gas tightness testing has been undertaken on the regulator assembly at the factory;
    5. where the operating pressure at the outlet of the meter is nominally 37 mbar.

    Installation pipework is specified in BS 5482-1 and LPGA Code of Practice 25 [14].

    Service pipework (including the first emergency control valve) is specified in BS 5482-1 and the LPGA Code of Practice 22 [15] and LPGA Code of Practice 25 [14].

    This standard does not cover pressure regulating installations installed in a service pipework upstream of the emergency control valve.

    NOTE 2 All pressures quoted in this standard are gauge pressures and all pressure absorption values are for liquefied petroleum gas unless otherwise specified.

    NOTE 3 Additional guidance on domestic gas systems can be found in the European functional standards BS EN 1775.

    NOTE 4 For additional guidance on the installation of gas meters in caravan holiday homes, residential park homes and permanently moored boats, reference should be made to IGE/UP/8 [16].

    General Product Information - (Show below) - (Hide below)

    Committee GSE/30
    Development Note Supersedes 06/30086669 DC. Together with BS 6400-1(2006) and BS 6400-2(2006) supersedes BS 6400(1997). (12/2007) Reviewed and confirmed by BSI, October 2012. (09/2012)
    Document Type Standard
    Publisher British Standards Institution
    Status Current
    Supersedes

    Standards Referenced By This Book - (Show below) - (Hide below)

    10/30213917 DC : 0 BS 8660-1 - GAS-FIRED MICRO-COGENERATION APPLIANCES OF RATED THERMAL INPUT NOT EXCEEDING 70 KW NET - PART 1: SPECIFICATION FOR SELECTION, INSTALLATION, INSPECTION, COMMISSIONING, SERVICING AND MAINTENANCE OF STIRLING ENGINE MICRO-COGENERATION APPLIANCES
    BS 5546:2010 Specification for installation and maintenance of gas-fired water-heating appliances of rated input not exceeding 70 kW net
    13/30261683 DC : 0 BS 6798 - SPECIFICATION FOR SELECTION, INSTALLATION, INSPECTION, COMMISSIONING, SERVICING AND MAINTENANCE OF GAS-FIRED BOILERS OF RATED INPUT NOT EXCEEDING 70 KW NET
    BS 6798:2009 Specification for installation and maintenance of gas-fired boilers of rated input not exceeding 70 kW net
    BS 6891:2015 Specification for the installation and maintenance of low pressure gas installation pipework of up to 35 mm (R1¼) on premises
    BS 6798:2014 Specification for selection, installation, inspection, commissioning, servicing and maintenance of gas-fired boilers of rated input not exceeding 70 kW net
    09/30166542 DC : 0 BS 5546 - SPECIFICATION FOR INSTALLATION AND MAINTENANCE OF GAS-FIRED WATER-HEATING APPLIANCES OF RATED INPUT NOT EXCEEDING 70 KW NET
    BS 8660-1:2011 Gas-fired micro-cogeneration appliances of rated thermal input not exceeding 70 kW net Specification for selection, installation, inspection, commissioning, servicing and maintenance of Stirling engine micro-cogeneration appliances

    Standards Referencing This Book - (Show below) - (Hide below)

    BS EN 437 : 2003 TEST GASES - TEST PRESSURES - APPLIANCE CATEGORIES
    BS 4161-5:1990 Gas meters Specification for diaphragm meters for working pressures up to 7 bar
    BS 6004:2000 Electric cables. PVC insulated, non-armoured cables for voltages up to and including 450/750 V, for electric power, lighting and internal wiring
    BS EN 1359:2017 Gas meters. Diaphragm gas meters
    BS 6400-2:2006 Specification for installation, exchange, relocation and removal of gas meters with a maximum capacity not exceeding 6 m3/h Medium pressure (2nd family gases)
    BS 7671(2008) : 2008 REQUIREMENTS FOR ELECTRICAL INSTALLATIONS - IET WIRING REGULATIONS
    BS EN 1057 : 2006 COPPER AND COPPER ALLOYS - SEAMLESS, ROUND COPPER TUBES FOR WATER AND GAS IN SANITARY AND HEATING APPLICATIONS
    BS EN 60079-10:2003 Electrical apparatus for explosive gas atmospheres Classification of hazardous areas
    BS EN ISO 10806:2003 Pipework. Fittings for corrugated metal hoses
    BS EN 14236:2007 Ultrasonic domestic gas meters
    BS EN 1775:2007 Gas supply. Gas pipework for buildings. Maximum operating pressure less than or equal to 5 bar. Functional recommendations
    BS EN 13785 : 2005 REGULATORS WITH A CAPACITY OF UP TO AND INCLUDING 100 KG/H, HAVING A MAXIMUM NOMINAL OUTLET PRESSURE OF UP TO AND INCLUDING 4 BAR, OTHER THAN THOSE COVERED BY EN 12864 AND THEIR ASSOCIATED SAFETY DEVICES FOR BUTANE, PROPANE OR THEIR MIXTURES
    BS 4781:1990 Specification for pressure-sensitive adhesive plastics labels for permanent use
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective