• BS 6708:1991

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    Specification for flexible cables for use at mines and quarries

    Available format(s):  Hardcopy, PDF

    Superseded date:  15-04-1998

    Language(s):  English

    Published date:  20-12-1991

    Publisher:  British Standards Institution

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    Committees responsible
    Foreword
    Specification
    Section 1. General
    1 Scope
    2 Definitions
    3 Abbreviations
    4 Voltage designation
    Section 2. Cables with individual metallic screens,
                rated voltage 640/1100 V, for use with coal-
                cutters and for similar purposes (types 7,
                7M, 7S, 11, 14 and 16) and flat cables for
                use on overhead catenary systems and for
                similar purposes (type FS4)
    5 Types of cable
    6 Conductors
    7 Insulation
    8 Thickness of insulation
    9 Core tape
    10 Core identification
    11 Protective screen
    12 Central filler
    13 Laying-up of cores
    14 Sheath of pilot unit and outer sheath
    15 Marking
    16 Tests on cores
    17 Tests on completed cable
    Section 3. Cables with galvanized steel pliable wire
                armouring, rated voltages up to 1900/3300 V
                (types 20, 21, 62, 63, 64, 70, 71, 201, 211,
                321 and 331)
    18 Types of cable
    19 Conductors
    20 Insulation
    21 Thickness of insulation
    22 Core tape
    23 Core identification
    24 Protective screen
    25 Central filler or cradle separator
    26 Laying-up of cores
    27 Sheath under armour
    28 Armour
    29 Outer sheath
    30 Marking
    31 Tests on cores
    32 Tests on completed cable
    Section 4. Cables with galvanized steel pliable wire
                armouring having up to 24 individual
                screened cores rated voltage 320/550 V
                (types 506, 512, 518 and 524)
    33 Types of cable
    34 Construction
    35 Conductors
    36 Insulation
    37 Thickness of insulation
    38 Core identification
    39 Protective screen
    40 Central filler
    41 Laying-up of cores
    42 Sheath under armour
    43 Armour
    44 Outer sheath
    45 Marking
    46 Tests on cores
    47 Tests on completed cable
    Section 5. Cables with galvanized steel pliable wire
                armouring having individual metallic
                screened or unscreened cores rated voltage
                3800/6600 V (types 621, 630 and 631)
    48 Types of cable
    49 Conductors
    50 Insulation
    51 Thickness of insulation
    52 Core tape
    53 Core identification
    54 Protective screen
    55 Central filler
    56 Laying-up of cores
    57 Sheath under armour
    58 Armour
    59 Outer sheath
    60 Marking
    61 Tests on cores
    62 Tests on comleted cable
    Section 6. Cables with individual metallic screens,
                rated voltage 600/1000 V, for use with
                drills (type 44)
    63 Types of cable
    64 Conductors
    65 Insulation
    66 Thickness of insulation
    67 Core tape
    68 Core identification
    69 Protective screen
    70 Laying-up of cores
    71 Outer sheath
    72 Marking
    73 Tests on cores
    74 Tests on completed cable
    Section 7. Cables with individual non-metallic screens,
                rated voltage 600/1000 V, for use with
                drills (type 43)
    75 Type of cable
    76 Conductors
    77 Insulation
    78 Conducting elastomeric screen
    79 Thickness of insulation and covering
    80 Core identification
    81 Cradle separator
    82 Laying-up of cores
    83 Screen over laid-up cores
    84 Outer sheath
    85 Marking
    86 Tests on cores
    87 Tests on completed cable
    88 Electrical test on conducting elastomeric screen
    Section 8. Cable with individual metallic screened
                cores, non-armoured, rated voltage 3800/6600
                V (type 730)
    89 Type of cable
    90 Conductors
    91 Insulation
    92 Thickness of insulation
    93 Core tape
    94 Core identification
    95 Protective screen
    96 Central filler
    97 Laying-up of cores
    98 Outer sheath
    99 Marking
    100 Tests on cores
    101 Test on completed cable
    Section 9. Cable with metallic screened cores, non-
                armoured, rated voltage 6350/11 000 V (type
                830)
    102 Type of cable
    103 Conductors
    104 Insulation
    105 Thickness of insulation
    106 Core tape
    107 Core identification
    108 Protective screen
    109 Central filler
    110 Laying-up of cores
    111 Outer sheath
    112 Marking
    113 Tests on cores
    114 Tests on completed cable
    Appendices
    A Recommended current ratings
    B Short circuit current-carrying capability of
         flexible cable screens
    C Measurement of insulation and sheath thickness
    D Protective screens: form, method of application and
         material
    E Voltage and insulation resistance tests
    F Tests for galvanized steel wire taken from
         completed cables
    G Electrical test for conducting elastomeric screen
         for type 43 cable
    NUMEROUS TABLES
    Figures
    1 Core identification: type 506 cable
    2 Core identification: type 512 cable
    3 Core identification: type 518 cable
    4 Core identification: type 524 cable
    5 Positions for first measurement of insulation
         thickness
    6 Positions of point of intersection of cross-wires
         of the measuring microscope
    7 Position for measurement of sheath thickness
    8 Position for measurement of sheath thickness for
         type FS4 cable
    9 Positions of point of intersection of cross-wires
         of the measuring microscope

    Abstract - (Show below) - (Hide below)

    Specifies flexible cable types, their electrical characteristics, construction, identification and testing.

    General Product Information - (Show below) - (Hide below)

    Committee W/-
    Development Note SUPERSEDES BS 6708: 1977 AND BS 6116: 1970. BS DRAFT 96/708618 DC
    Document Type Standard
    Publisher British Standards Institution
    Status Superseded
    Superseded By
    Supersedes

    Standards Referenced By This Book - (Show below) - (Hide below)

    BS 7375:1996 Code of practice for distribution of electricity on construction and building sites
    BS 6704:1996 Code of practice for selection, installation and maintenance of intrinsically safe electrical equipment in coal mines

    Standards Referencing This Book - (Show below) - (Hide below)

    IEC 60724:2000+AMD1:2008 CSV Short-circuit temperature limits of electric cables with rated voltages of 1 kV (Um = 1,2 kV) and 3 kV (Um = 3,6 kV)
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective