• BS 7041:1989

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    Specification for characteristics and calibration of hydrophones for operation in the frequency range 0.5 MHz to 15 MHz

    Available format(s):  Hardcopy, PDF

    Superseded date:  30-05-2008

    Language(s):  English

    Published date:  28-02-1989

    Publisher:  British Standards Institution

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    National foreword
    Committees responsible
    List of symbols
    1 Scope
    2 Object
    3 Definitions
    3.1 Free field
    3.2 Far field
    3.3 Acoustic centre
    3.4 Hydrophone (or receiver)
    3.5 Reversible transducer
    3.6 Reciprocal transducer
    3.7 Open-circuit voltage at hydrophone
    3.8 Free-field sensitivity of a hydrophone
    3.9 Free-field sensitivity level
    3.10 Transmitting response to current of a projector
    3.11 Reciprocity coefficient
    3.12 Direction response of a hydrophone
    3.13 End-of-cable leakage resistance
    3.14 Mechanical Q of hydrophone element
    4 General introduction
    4.1 Choice of measurement method
    4.2 Basis of recommendations
    4.3 Effect of the finite size of hydrophones
    4.4 Hydrophone calibration
    5 Hydrophone characteristics
    5.1 Sensitivity
    5.2 Directivity
    5.3 Electrical characteristics
    5.4 Mechanical characteristics
    6 Specification of performance of a hydrophone
    6.1 Free-field voltage sensitivity
    6.2 Directivity
    6.3 Electrical aspects
    6.4 Mechanical and environmental aspects
    7 Hydrophone calibration
    7.1 Reciprocity techniques
    7.2 Principle of the two-transducer reciprocity method
    7.3 Calibration measurement conditions
    7.4 Experimental method
    7.5 Calculation of results
    7.6 Accuracy
    Appendices
    A Rationale for the reciprocity procedure
    B Plane wave reciprocity
    C Details of the recommended experimental procedures
    D Evaluation of the correction factor, k
    E Bibliography
    Figures

    Abstract - (Show below) - (Hide below)

    Defines performance characteristics of hydrophones for use in a specified range of applications, particularly those associated with the measurement of pulsed and continuous-wave ultrasonic fields used in medical diagnosis. Establishes a scheme for specification of performance and standard procedure for calibration.

    General Product Information - (Show below) - (Hide below)

    Committee EPL/87
    Development Note Also numbered as IEC 60866. (09/2005)
    Document Type Standard
    Publisher British Standards Institution
    Status Superseded
    Superseded By

    Standards Referenced By This Book - (Show below) - (Hide below)

    BS EN 61102:1994 Specification for measurement and characterisation of ultrasonic fields using hydrophones in the frequency range 0.5 MHz to 15 MHz
    BS 7887:1997 Ultrasonics. Real-time pulse-echo systems. Guide for test procedures to determine performance specifications
    BS EN 61266:1995 Ultrasonics. Hand-held probe Doppler foetal heartbeat detectors. Performance requirements and methods of measurement and reporting
    BS EN 61101:1994 Specification for absolute calibration of hydrophones using the planar scanning technique in the frequency range 0,5 MHz to 15 MHz

    Standards Referencing This Book - (Show below) - (Hide below)

    BS 5652:1979 Specification for the calibration of hydrophones
    BS 5653:1978 Specification for hydrophones for calibration purposes