• BS 7698-12:1998

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    Reciprocating internal combustion engine driven alternating current generating sets Emergency power supply to safety devices

    Available format(s):  Hardcopy, PDF

    Superseded date:  13-09-2022

    Language(s):  English

    Published date:  01-05-1999

    Publisher:  British Standards Institution

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    1 Scope
    2 Normative references
    3 Definitions
    4 Symbols
    5 Additional regulations and requirements
    6 Classification designation
        6.1 General
        6.2 Typical examples of classification
    7 Generating set design
        7.1 Criteria for determining the required power
        7.2 Power determination
        7.3 Operating limit values
    8 Additional requirements
    9 Controlgear and switchgear
        9.1 Protection, measurement, monitoring and control
              equipment for the generator
        9.2 Engine measurement and monitoring equipment
        9.3 Generating set measurement and monitoring equipment
        9.4 Remote signals
    10 Test mode
        10.1 Test operation with synchronization to the mains
              supply
        10.2 Test mode without mains synchronization
    11 Testing
        11.1 General
        11.2 Installation tests
        11.3 Periodic tests
    12 Rating plate
    13 Required documentation
    14 Check list
    Annex A (informative) Bibliography

    Abstract - (Show below) - (Hide below)

    Applicable to generating sets driven by reciprocating internal-combustion (RIC) engines for supply of emergency power to safety services, such as hospitals, high-rise buildings, public-gathering places and so on. Defines special needs for performing, designing, and maintaining power generators for use in the applications named above, taking into account the provisions of ISO 8528-1 to ISO 8528-6 and ISO 8528-10.

    Scope - (Show below) - (Hide below)

    This part of ISO 8528 applies to generating sets driven by reciprocating internal-combustion (RIC) engines for emergency power supply to safety services.

    It applies, for example, to safety equipments in hospitals, high-rise buildings, public gathering places etc. This part of ISO 8528 establishes the special requirements for the performance, design and maintenance of power generators used in the applications referred to above and taking into account the provisions of ISO 8528-1 to ISO 8528-6 and ISO 8528-10.

    General Product Information - (Show below) - (Hide below)

    Committee MCE/14
    Development Note Also numbered as ISO 8528-12 Supersedes 95/703356 DC (10/2005)
    Document Type Standard
    Publisher British Standards Institution
    Status Superseded
    Superseded By

    Standards Referenced By This Book - (Show below) - (Hide below)

    BS 7671(2008) : 2018 REQUIREMENTS FOR ELECTRICAL INSTALLATIONS - IET WIRING REGULATIONS
    BS 7671(2008) : 2008 REQUIREMENTS FOR ELECTRICAL INSTALLATIONS - IET WIRING REGULATIONS

    Standards Referencing This Book - (Show below) - (Hide below)

    IEC 60146-4:1986 Semiconductor convertors. Part 4: Method of specifying the performance and test requirements of uninterruptible power systems
    IEC 60896-1:1987 Stationary lead-acid batteries - General requirements and methods of test. Part 1: Vented types
    IEC 60146-1-3:1991 Semiconductor convertors - General requirements and line commutated convertors - Part 1-3: Transformers and reactors
    IEC 60364-5-56:2009 Low-voltage electrical installations - Part 5-56: Selection and erection of electrical equipment - Safety services
    IEC 60364-7-710:2002 Electrical installations of buildings - Part 7-710: Requirements for special installations or locations - Medical locations
    ISO 8528-3:2005 Reciprocating internal combustion engine driven alternating current generating sets Part 3: Alternating current generators for generating sets
    ISO 8528-2:2005 Reciprocating internal combustion engine driven alternating current generating sets Part 2: Engines
    IEC 60601-1:2005+AMD1:2012 CSV Medical electrical equipment - Part 1: General requirements for basic safety and essential performance
    ISO 8528-6:2005 Reciprocating internal combustion engine driven alternating current generating sets — Part 6: Test methods
    ISO 8528-5:2013 Reciprocating internal combustion engine driven alternating current generating sets Part 5: Generating sets
    ISO 8528-4:2005 Reciprocating internal combustion engine driven alternating current generating sets — Part 4: Controlgear and switchgear
    IEC 60146-1-1:2009 Semiconductor converters - General requirements and line commutated converters - Part 1-1: Specification of basic requirements
    IEC 60896-2:1995 Stationary lead-acid batteries - General requirements and test methods - Part 2: Valve regulated types
    IEC 60146-2:1999 Semiconductor converters - Part 2: Self-commutated semiconductor converters including direct d.c. converters
    IEC 60364-3:1993 Electrical installations of buildings - Part 3: Assessment of general characteristics
    IEC 60364-6-61:2001 Electrical installations of buildings - Part 6-61: Verification - Initial verification
    IEC 60034-1:2017 Rotating electrical machines - Part 1: Rating and performance
    ISO 8528-1:2005 Reciprocating internal combustion engine driven alternating current generating sets Part 1: Application, ratings and performance
    IEC 60623:2017 Secondary cells and batteries containing alkaline or other non-acid electrolytes - Vented nickel-cadmium prismatic rechargeable single cells
    IEC 60285:1993+AMD1:1995+AMD2:1998 CSV Alkaline secondary cells and batteries - Sealed nickel-cadmium cylindrical rechargeable single cells
    IEC 60622:2002 Secondary cells and batteries containing alkaline or other non-acid electrolytes - Sealed nickel-cadmium prismatic rechargeable single cells