• BS 7870-3.50:2005

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    LV and MV polymeric insulated cables for use by distribution and generation utilities Specification for distribution cables of rated voltage 0.6/1 kV. XLPE insulated, copper wire waveform or helical concentric cables with solid aluminium conductors, having low emission of smoke and corrosive gases when affected by fire. (Implementation of HD 603)

    Available format(s):  Hardcopy, PDF

    Superseded date:  31-12-2011

    Language(s):  English

    Published date:  04-10-2005

    Publisher:  British Standards Institution

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    Committees responsible
    Foreword
    1 Scope
    2 Normative references
    3 Voltage designation
    4 Core conductors
    5 Insulation
    6 Assembly of cores
    7 Concentric conductor
    8 Oversheath
    9 Marking
    10 End sealing
    11 Dimensions
    12 Tests
    13 Routine tests
    14 Sample tests
    15 Type tests
    Annex A (normative) Test for shrinkage of oversheath on cable
    Bibliography

    Abstract - (Show below) - (Hide below)

    Describes requirements for the construction, dimensions and mechanical and electrical properties of XLPE insulated, concentric copper wire screened waveform or helical cables with solid aluminium core conductors having a rated voltage of 0.6/1(1.2) kV.

    General Product Information - (Show below) - (Hide below)

    Committee GEL/20/16
    Development Note To be read in conjunction with BS 7870-1(1996) & BS 7870-2(1999) Supersedes 05/30126924 DC. (10/2005)
    Document Type Standard
    Publisher British Standards Institution
    Status Superseded
    Superseded By
    Supersedes

    Standards Referencing This Book - (Show below) - (Hide below)

    HD 622 S1:1996/A2:2005 Power cables having rated voltages from 3,6/6 (7,2) kV up to and including 20,8/36 (42) kV with special fire performance for use in power stations
    HD 627 S1:1996/A2:2005 MULTICORE AND MULTIPAIR CABLES FOR INSTALLATION ABOVE AND BELOW GROUND
    BS EN 50268-2:2000 Common test methods for cables under fire conditions. Measurement of smoke density of cables burning under defined conditions Procedure
    BS EN 50268-1:2000 Common test methods for cables under fire conditions. Measurement of smoke density of cables burning under defined conditions Apparatus
    BS EN 60332-1-2 : 2004 TESTS ON ELECTRIC AND OPTICAL FIBRE CABLES UNDER FIRE CONDITIONS - PART 1-2: TEST FOR VERTICAL FLAME PROPAGATION FOR A SINGLE INSULATED WIRE OR CABLE - PROCEDURE FOR 1 KW PRE-MIXED FLAME (IEC 60332-1-2:2004)
    HD 605 S2:2008/corrigendum:2010 ELECTRIC CABLES - ADDITIONAL TEST METHODS
    HD 620 : 2010 DISTRIBUTION CABLES WITH EXTRUDED INSULATION FOR RATED VOLTAGES FROM 3,6/6 (7,2) KV UP TO AND INCLUDING 20,8/36 (42) KV
    BS EN 50267-2-1:1999 Common test methods for cables under fire conditions. Tests on gases evolved during combustion of materials from cables. Procedures Determination of the amount of halogen acid gas - Determination of the amount of halogen acid gas
    BS EN 13602:2013 Copper and copper alloys. Drawn, round copper wire for the manufacture of electrical conductors
    BS EN 60811-1-3:1995 Insulating and sheathing materials of electric cables. Common test methods. General application Methods for determining the density. Water absorption tests. Shrinkage test
    HD 603 S1:1994/A3:2007 DISTRIBUTION CABLES OF RATED VOLTAGE 0,6/1 KV
    HD 626 S1:1996/A2:2002 OVERHEAD DISTRIBUTION CABLES OF RATED VOLTAGE U[O]/U(U[M]): 0,6/1 (1,2) KV
    BS 7870-3.40:2001 LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for distribution cables of rated voltage 0.6/1 kV XLPE insulated, copper wire waveform concentric cables with solid aluminium conductors
    BS EN 60811-1-2:1995 Insulating and sheathing materials of electric cables. Common test methods. General application Thermal ageing methods
    BS EN 50266-2-4:2001 Common test methods for cables under fire conditions. Test for vertical flame spread of vertically-mounted bunched wires or cables. Procedures Category C
    HD 604 S1:1994/A3:2005 0.6/1 KV POWER CABLES WITH SPECIAL FIRE PERFORMANCE FOR USE IN POWER STATIONS