• BS 7924:1999

    Withdrawn A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

    Code of practice for the repair and overhaul of certified electrical apparatus intended for use in mines susceptible to firedamp

    Available format(s):  Hardcopy, PDF

    Withdrawn date:  04-03-2024

    Language(s):  English

    Published date:  15-11-1999

    Publisher:  British Standards Institution

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    Committees responsible
          Foreword
    0 Introduction
    1 Scope
    2 Normative references
    3 Terms and definitions
    4 General
    5 Statutory requirements
    6 Responsibilities of the manufacturer
    7 Responsibilities of the user
    8 Responsibilities of the repairer
    9 Identification of repaired and overhauled apparatus
    10 Reclamation
    11 Removal of damaged windings
    12 Encapsulated parts
    13 Light-transmitting parts
    14 Temporary repairs
    15 Cleaning agents and finishes
    16 Repair of flameproof apparatus (Type "d")
    17 Repair of intrinsically safe (IS) apparatus
          (type "i")
    18 Repair of increased safety apparatus (type "e")
    Annex A (informative) Statutory duties
    Bibliography
    Figure 1 - Symbols indicating status of repair/overhaul
    Table 1 - Resistance of insulation of windings

    Abstract - (Show below) - (Hide below)

    Provides recommendations for repair, reclamation, overhaul and modification of certified electrical apparatus intended for use in mines susceptible to firedamp.

    Scope - (Show below) - (Hide below)

    This British Standard gives recommendations for the repair, overhaul, reclamation and modification of certified electrical apparatus intended for use in mines susceptible to firedamp (defined as “Group I” apparatus in the explosion protection concept standard BS EN 50014:1998).

    Maintenance is not covered, other than where this cannot be dissociated from repair and overhaul. It does not give advice on the use of electrical apparatus or the prevention of any hazards other than ignition of an explosive atmosphere. Similarly, it does not give advice on cable entry systems which may require renewal when the apparatus is re-installed.

    NOTE 1 Recommendations regarding routine maintenance, and the selection and installation of intrinsically safe electrical apparatus for use in potentially explosive atmospheres in mines, are given in BS 6704.

    NOTE 2 The contract between the user and the repairer will need to address other safety-related matters beyond the scope of this document, e.g. prevention of electric shock, electrical protection (overload, short circuit, earth leakage) and electrical/mechanical interlocking.

    Clauses 4 to 9 give general recommendations applicable to persons involved in the repair and/or overhaul of electrical apparatus intended for use in potentially explosive atmospheres found in coal mines. They also identify certain specific responsibilities under the Health and Safety at Work etc. Act 1974 [6] as applicable to those who are likely to be concerned with the repair of certified apparatus.

    Clauses 10 to 15 cover those aspects of repair and overhaul which are common to all explosion protected apparatus.

    Clauses 16 to 18 give recommendations applicable to specific types of explosion protected apparatus. This standard excludes apparatus having the following forms of protection, which is generally considered irreparable: oil immersion “o”; pressurized “p”; powder filling “q”; and encapsulation “m”.

    NOTE 3 Apparatus which contains oil is installed in British mines, but such equipment should be repaired in accordance with this standard and that to which it was certified.

    General Product Information - (Show below) - (Hide below)

    Committee W/-
    Development Note Supersedes 96/715959 DC. (09/2005) Reviewed and confirmed by BSI, January 2011. (12/2010)
    Document Type Standard
    Publisher British Standards Institution
    Status Withdrawn
    Supersedes

    Standards Referencing This Book - (Show below) - (Hide below)

    EN 50039:1980 Electrical apparatus for potentially explosive atmospheres - Intrinsically safe electrical systems 'i'
    BS EN 50014:1998 Electrical apparatus for potentially explosive atmospheres. General requirements
    BS 5901:1980 Method of test for determining the comparative and the proof tracking indices of solid insulating materials under moist conditions
    BS 4761:1971 Specification for sprayed unfused metal coatings for engineering purposes
    EN 50017:1998 Electrical apparatus for potentially explosive atmospheres - Powder filling "q"
    BS 5501-9:1982 Electrical apparatus for potentially explosive atmospheres Specification for intrinsically safe electrical systems \'i\'
    BS 5501-4:1977 Electrical apparatus for potentially explosive atmospheres Powder filling \'q\'
    BS 5501-7:1977 Electrical apparatus for potentially explosive atmospheres Intrinsic safety \'i\'
    BS 5501-6:1977 Electrical apparatus for potentially explosive atmospheres Increased safety \'e\'
    BS EN 50019:2000 Electrical apparatus for potentially explosive atmospheres. Increased safety \'e\'
    BS 5501-1:1977 Electrical apparatus for potentially explosive atmospheres General requirements
    BS 6704:1996 Code of practice for selection, installation and maintenance of intrinsically safe electrical equipment in coal mines
    BS 5501-5:1977 Electrical apparatus for potentially explosive atmospheres Flameproof enclosure \'d\'
    BS 4683-1:1971 Specification for electrical apparatus for explosive atmospheres Classification of maximum surface temperatures
    BS 5501-8:1988 Electrical apparatus for potentially explosive atmospheres Encapsulation \'m\'
    BS 5501-2:1977 Electrical apparatus for potentially explosive atmospheres Oil immersion \'o\'
    BS 4999-143:1987 General requirements for rotating electrical machines Specification for tests
    EN 50015:1998 Electrical apparatus for potentially explosive atmospheres - Oil immersion "o"
    BS 4683-2:1971 Specification for electrical apparatus for explosive atmospheres The construction and testing of flameproof enclosures of electrical apparatus
    EN 50016:2002 Electrical apparatus for potentially explosive atmospheres - Pressurized apparatus "p"
    BS EN ISO 9002:1994 Quality systems. Model for quality assurance in production, installation and servicing
    EN 50028:1987 Electrical apparatus for potentially explosive atmospheres - Encapsulation 'm'
    EN 50014:1997/A2:1999 ELECTRICAL APPARATUS FOR POTENTIALLY EXPLOSIVE ATMOSPHERES - GENERAL REQUIREMENTS
    BS 5501-3:1977 Electrical apparatus for potentially explosive atmospheres Pressurized apparatus \'p\'
    BS EN 50020:2002 Electrical apparatus for potentially explosive atmospheres. Intrinsic safety \'i\'
    BS EN 50018:2000 Electrical apparatus for potentially explosive atmospheres. Flameproof enclosure \'d\'
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective