• BS EN 50436-1:2014

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    Alcohol interlocks. Test methods and performance requirements Instruments for drink-driving-offender programs

    Available format(s):  Hardcopy, PDF

    Superseded date:  19-07-2023

    Language(s):  English

    Published date:  31-01-2014

    Publisher:  British Standards Institution

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    Foreword
    Introduction
    1 Scope
    2 Normative references
    3 Terms and definitions
    4 General requirements
    5 General test methods
    6 Electrical tests
    7 Calibration curve
    8 Durability tests
    9 Environmental tests
    10 Breath sample
    11 Analytical specificity
    12 Manipulation and circumvention
    13 Timer
    14 Long term behaviour
    15 Instructions
    16 Test report
    17 Labelling and marking
    Annex A (normative) - Description of events
    Annex B (informative) - Performance testing
    Bibliography

    Abstract - (Show below) - (Hide below)

    Defines test methods and performance requirements for breath alcohol controlled alcohol interlocks.

    Scope - (Show below) - (Hide below)

    This European Standard specifies test methods and performance requirements for breath alcohol controlled alcohol interlocks. It covers alcohol interlocks intended to be used in programmes for drink driving offenders as well as in programmes monitored or controlled in a comparable way.

    This European Standard is directed at test laboratories and manufacturers of alcohol interlocks. It defines requirements and test procedures for type testing.

    Several parameters (such as alcohol concentration or breath volume) are specified in this European Standard for the purpose of type testing according to this standard only. However, it may be necessary due to national regulations or depending on user requests to set the values of the prescribed parameters differently when the alcohol interlocks are in use.

    This European Standard also applies to alcohol interlocks integrated into other control systems of the vehicle as well as to accessory devices connected to the alcohol interlock.

    This European Standard does not apply to

    • alcohol interlocks intended for general preventive use (see EN 50436-2),

    • instruments measuring the alcohol concentration in the ambient air in the vehicle,

    • alcohol interlocks not having a mouthpiece,

    • methods of installation and connections to the vehicle.

    General Product Information - (Show below) - (Hide below)

    Committee AUE/16
    Development Note Supersedes 04/30115398 DC. (02/2006) Supersedes 12/30260709 DC. (01/2014)
    Document Type Standard
    Publisher British Standards Institution
    Status Superseded
    Superseded By
    Supersedes

    Standards Referencing This Book - (Show below) - (Hide below)

    ISO 16750-2:2012 Road vehicles — Environmental conditions and testing for electrical and electronic equipment — Part 2: Electrical loads
    ISO 16750-4:2010 Road vehicles — Environmental conditions and testing for electrical and electronic equipment — Part 4: Climatic loads
    ISO 7637-3:2016 Road vehicles — Electrical disturbances from conduction and coupling — Part 3: Electrical transient transmission by capacitive and inductive coupling via lines other than supply lines
    ISO 16750-1:2006 Road vehicles Environmental conditions and testing for electrical and electronic equipment Part 1: General
    EN 50436-2 : 2014 AMD 1 2015 ALCOHOL INTERLOCKS - TEST METHODS AND PERFORMANCE REQUIREMENTS - PART 2: INSTRUMENTS HAVING A MOUTHPIECE AND MEASURING BREATH ALCOHOL FOR GENERAL PREVENTIVE USE
    ISO 7637-2:2011 Road vehicles Electrical disturbances from conduction and coupling Part 2: Electrical transient conduction along supply lines only
    ISO 10605:2008 Road vehicles — Test methods for electrical disturbances from electrostatic discharge
    ISO 16750-3:2012 Road vehicles — Environmental conditions and testing for electrical and electronic equipment — Part 3: Mechanical loads
    IEC 60529:1989+AMD1:1999+AMD2:2013 CSV Degrees of protection provided by enclosures (IP Code)
    OIML R 126 : 2012 EVIDENTIAL BREATH ANALYZERS
    EN 60068-2-78:2013 Environmental testing - Part 2-78: Tests - Test Cab: Damp heat, steady state
    EN 60529:1991/AC:2016-12 DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015)
    CLC/TR 50436-3 : 2010 ALCOHOL INTERLOCKS - TEST METHODS AND PERFORMANCE REQUIREMENTS - PART 3: GUIDANCE FOR DECISION MAKERS, PURCHASERS AND USERS
    AS 3547-1997 Breath alcohol testing devices for personal use
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective