• BS EN 50600-2-2:2014

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    Information technology. Data centre facilities and infrastructures Power distribution

    Available format(s):  Hardcopy, PDF

    Superseded date:  19-06-2019

    Language(s):  English

    Published date:  30-04-2014

    Publisher:  British Standards Institution

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    Foreword
    Introduction
    1 Scope
    2 Normative references
    3 Terms, definitions and abbreviations
    4 Conformance
    5 Power supply and distribution within
      data centres
    6 Availability
    7 Physical security
    8 Energy efficiency enablement and
      power distribution
    Annex A (informative) - Example implementations of
            power distribution
    Bibliography

    Abstract - (Show below) - (Hide below)

    Defines requirements and recommendations for the following: a) power supplies to data centres; b) power distribution systems within data centres; c) facilities for both normal and emergency lighting; d) equipotential bonding and earthing; e) lightning protection; f) devices for the measurement of the power consumption characteristics at points along the power distribution system and their integration within management tools.

    Scope - (Show below) - (Hide below)

    This European Standard addresses power supplies to, and power distribution within, data centres based upon the criteria and classifications for “availability??, “physical security?? and “energy efficiency enablement?? within EN 50600-1. This European Standard specifies requirements and recommendations for the following: power supplies to data centres; power distribution systems within data centres; facilities for both normal and emergency lighting; equipotential bonding and earthing; lightning protection; devices for the measurement of the power consumption characteristics at points along the power distribution system and their integration within management tools. Safety and electromagnetic compatibility (EMC) requirements are outside the scope of this European Standard and are covered by other standards and regulations. However, information given in this European Standard may be of assistance in meeting these standards and regulations. Conformance of data centres to the present document is covered in Clause 4.

    General Product Information - (Show below) - (Hide below)

    Committee TCT/7
    Document Type Standard
    Publisher British Standards Institution
    Status Superseded
    Superseded By

    Standards Referencing This Book - (Show below) - (Hide below)

    EN 50160 : 2010 AMD 1 2015 VOLTAGE CHARACTERISTICS OF ELECTRICITY SUPPLIED BY PUBLIC ELECTRICITY NETWORKS
    IEC 60050-131:2002 International Electrotechnical Vocabulary (IEV) - Part 131: Circuit theory
    IEC 61000-2-4:2002 Electromagnetic compatibility (EMC) - Part 2-4: Environment - Compatibility levels in industrial plants for low-frequency conducted disturbances
    EN 50600-2-1:2014 Information technology - Data centre facilities and infrastructures - Part 2-1: Building construction
    EN 62305-4:2011/AC:2016 PROTECTION AGAINST LIGHTNING - PART 4: ELECTRICAL AND ELECTRONIC SYSTEMS WITHIN STRUCTURES (IEC 62305-4:2010)
    EN 50174-1:2009/A2:2014 INFORMATION TECHNOLOGY - CABLING INSTALLATION - PART 1: INSTALLATION SPECIFICATION AND QUALITY ASSURANCE
    EN 61000-2-4:2002/AC:2014 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 2-4: ENVIRONMENT - COMPATIBILITY LEVELS IN INDUSTRIAL PLANTS FOR LOW-FREQUENCY CONDUCTED DISTURBANCES
    EN 60076-11:2004 Power transformers - Part 11: Dry-type transformers
    EN 50174-3:2013/A1:2017 INFORMATION TECHNOLOGY - CABLING INSTALLATION - PART 3: INSTALLATION PLANNING AND PRACTICES OUTSIDE BUILDINGS
    IEC 88528-11:2004 Reciprocating internal combustion engine driven alternating current generating sets - Part 11: Rotary uninterruptible power systems - Performance requirements and test methods
    HD 60364-4-444:2010/AC:2012 LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 4-444: PROTECTION FOR SAFETY - PROTECTION AGAINST VOLTAGE DISTURBANCES AND ELECTROMAGNETIC DISTURBANCES
    EN 50600-1:2012 INFORMATION TECHNOLOGY - DATA CENTRE FACILITIES AND INFRASTRUCTURES - PART 1: GENERAL CONCEPTS
    EN 50174-2 : 2009 AMD 2 2014 INFORMATION TECHNOLOGY - CABLING INSTALLATION - PART 2: INSTALLATION PLANNING AND PRACTICES INSIDE BUILDINGS
    IEC 60044-1:1996+AMD1:2000+AMD2:2002 CSV Instrument transformers - Part 1: Current transformers
    IEC 60364-4-44:2007+AMD1:2015 CSV Low-voltage electrical installations - Part 4-44: Protection for safety - Protection against voltage disturbances and electromagnetic disturbances
    EN 50600-2-4:2015 Information technology - Data centre facilities and infrastructures - Part 2-4: Telecommunications cabling infrastructure
    PREN 50600-2-5 : DRAFT 2012 BS EN 50600-2-5 - DATA CENTRE FACILITIES AND INFRASTRUCTURES - PART 2-5: SECURITY SYSTEMS
    PREN 50600-2-3 : DRAFT 2012 DATA CENTRE FACILITIES AND INFRASTRUCTURES - PART 2-3: ENVIRONMENTAL CONTROL
    EN 60044-1:1999/A2:2003 INSTRUMENT TRANSFORMERS - PART 1: CURRENT TRANSFORMERS
    IEC 62305-4:2010 Protection against lightning - Part 4: Electrical and electronic systems within structures
    EN 50310:2016 Telecommunications bonding networks for buildings and other structures
    EN 88528-11 : 2004 RECIPROCATING INTERNAL COMBUSTION ENGINE DRIVEN ALTERNATING CURRENT GENERATING SETS - PART 11: ROTARY UNINTERRUPTIBLE POWER SYSTEMS - PERFORMANCE REQUIREMENTS AND TEST METHODS
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective