• BS EN 60947-4-1:2010+A1:2012

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    Low-voltage switchgear and controlgear Contactors and motor-starters. Electromechanical contactors and motor-starters

    Available format(s):  Hardcopy, PDF

    Superseded date:  04-04-2022

    Language(s):  English

    Published date:  31-01-2013

    Publisher:  British Standards Institution

    Add To Cart

    Scope - (Show below) - (Hide below)

    This part of IEC 60947 applies to the types of equipment listed in 1.1.1 and 1.1.2 whose main contacts are intended to be connected to circuits the rated voltage of which does not exceed 1 000 V a.c. or 1 500 V d.c.

    Starters and/or contactors dealt with in this standard are not normally designed to interrupt short-circuit currents. Therefore, suitable short-circuit protection (see 9.3.4) forms part of the installation but not necessarily of the contactor or the starter.

    In this context, this standard gives requirements for:

    • contactors associated with overload and/or short-circuit protective devices;

    • starters associated with separate short-circuit protective devices and/or with separate short-circuit and integrated overload protective devices;

    • contactors or starters combined, under specified conditions, with their own short-circuit protective devices. Such combinations, e.g. combination starters or protected starters are rated as units.

    For circuit-breakers and fuse-combination units used as short-circuit protective devices in combination starters and in protected starters, the requirements of IEC 60947-2 and IEC 60947-3 respectively apply.

    Equipment covered by this standard is as follows.

    1.1.1 AC and DC contactors

    AC and DC contactors intended for closing and opening electric circuits and, if combined with suitable relays (see 1.1.2), for protecting these circuits against operating overloads which may occur therein.

    NOTE For contactors combined with suitable relays and which are intended to provide short-circuit protection, the relevant conditions specified for circuit-breakers (IEC 60947-2) additionally apply.

    This standard applies also to the actuators of contactor relays and to the contacts dedicated exclusively to the coil circuit of a contactor.

    Contactors or starters with an electronically controlled electromagnet are also covered by this standard.

    1.1.2 AC motor-starters

    AC motor-starters (including motor management starter) intended to start and accelerate motors to continuous operation of motors, to switch off the supply from normal speed, to ensure the motor and to provide means for the protection of motors and associated circuits against operating overloads.

    For overload relays for starters, including those based on electronic technology with or without extended functions according to Annex H, the requirements of this standard apply.

    1.1.2.1 Direct-on-line (full voltage) a.c. starters

    Direct-on-line starters intended to start and accelerate a motor to normal speed, to provide means for the protection of the motor and its associated circuits against operating overloads, and to switch off the supply from the motor.

    This standard applies also to reversing starters.

    1.1.2.2 Reduced voltage a.c. starters

    Reduced voltage a.c. starters intended to start and accelerate a motor to normal speed by connecting the line voltage across the motor terminals in more than one step or by gradually increasing the voltage applied to the terminals, to provide means for the protection of the motor and its associated circuits against operating overloads, and to switch off the supply from the motor.

    Automatic change-over devices may be used to control the successive switching operations from one step to the others. Such automatic change-over devices are, for example, time-delay contactor relays or specified time all-or-nothing relays, under-current devices and automatic acceleration control devices (see 5.10).

    1.1.2.2.1 Star-delta starters

    Star-delta starters intended to start a three-phase motor in the star connection, to ensure continuous operation in the delta connection, to provide means for the protection of the motor and its associated circuits against operating overloads, and to switch off the supply from the motor.

    The star-delta starters dealt with in this standard are not intended for reversing motors rapidly and, therefore, utilization category AC-4 does not apply.

    NOTE In the star connection, the starting current in the line and the torque of the motor are about one-third of the corresponding values for delta connection. Therefore, star-delta starters are used when the inrush current due to the starting is to be limited, or when the driven machine requires a limited torque for starting. Figure 1 indicates typical curves of starting current, of starting torque of the motor and of torque of the driven machine.

    1.1.2.2.2 Two-step auto-transformer starters

    Two-step auto-transformer starters, intended to start and accelerate an a.c. induction motor from rest with reduced torque to normal speed and to provide means for the protection of the motor and its associated circuits against operating overloads, and to switch off the supply from the motor.

    This standard applies to auto-transformers which are part of the starter or which constitute a unit specially designed to be associated with the starter.

    Auto-transformer starters with more than two steps are not covered by this standard.

    The auto-transformer starters dealt with in this standard are not intended for inching duty or reversing motors rapidly and, therefore, utilization category AC-4 does not apply.

    NOTE In the starting position, the current in the line and the torque of the motor related to the motor starting with rated voltage are reduced approximately as the square of the ratio (starting voltage):(rated voltage). Therefore, auto-transformer starters are used when the inrush current due to the starting is to be limited or when the driven machine requires a limited torque for starting. Figure 2 indicates typical curves of starting current, of starting torque of the motor and of torque of the driven machine.

    1.1.2.3 Rheostatic rotor starters

    Starters intended to start an a.c. induction motor having a wound rotor by cutting out resistors previously inserted in the rotor circuit, to provide means for the protection of the motor against operating overloads and to switch off the supply from the motor.

    Text deleted

    This standard applies also to starters for two directions of rotation when reversal of connections is made with the motor stopped (see 5.3.5.5). Operations including inching and plugging necessitate additional requirements and are subject to agreement between manufacturer and user.

    This standard applies to resistors which are part of the starter or constitute a unit specially designed to be associated with the starter.

    General Product Information - (Show below) - (Hide below)

    Committee PEL/17
    Document Type Standard
    Publisher British Standards Institution
    Status Superseded
    Supersedes
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective