• PD 60079-14:2000

    Withdrawn A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

    Guide to application of BS EN 60079-14

    Available format(s):  Hardcopy, PDF

    Withdrawn date:  01-07-2007

    Language(s):  English

    Published date:  15-01-2000

    Publisher:  British Standards Institution

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    Foreword to PD 60079-14
    Foreword
    Introduction
    1 Scope and object
    2 Normative references
    3 Definitions and terms [see IEC 50(426)]
    4 General
          4.1 General requirements
          4.2 Documentation
    5 Selection of electrical apparatus (excluding cables
          and conduits)
          5.1 Specific information
          5.2 Selection according to zones
          5.3 Selection according to the ignition temperature
                 of the gas or vapour
          5.4 Selection according to apparatus grouping
          5.5 External influences
    6 Protection from dangerous (incendive) sparking
          6.1 Danger from live parts
          6.2 Danger from exposed and extraneous conductive
                 parts
          6.3 Potential equalization
          6.4 Static electricity
          6.5 Lightning protection
          6.6 Electromagnetic radiation
          6.7 Cathodically protected metallic parts
    7 Electrical protection
    8 Emergency switch-off and electrical isolation
          8.1 Emergency switch-off
          8.2 Electrical isolation
    9 Wiring systems
          9.1 General
          9.2 Cable systems for Zone 0
          9.3 Cable systems for Zones 1 and 2
          9.4 Conduit systems
    10 Additional requirements for type of protection "d"
          - Flameproof enclosures
          10.1 Solid obstacles
          10.2 Protection of flameproof joints
          10.3 Cable entry systems
          10.4 Motors supplied at varying frequency and
                 voltage
          10.5 Conduit systems
    11 Additional requirements for type of protection "e"
          - Increased safety
          11.1 Degree of production of enclosures (IEC 34-5
                 and IEC 529)
          11.2 Cage induction motors - Thermal protection in
                 operation
          11.3 Wiring systems
          11.4 Resistance heating devices
    12 Additional requirements for type of protection "i"
          - Intrinsic safety
          12.1 Introduction
          12.2 Installation for Zones 1 and 2
          12.3 Installations for Zone 0
    13 Additional requirements for type of protection "p"
          - Pressurized apparatus
          13.1 Ducting
          13.2 Actions to be taken on failure of
                 pressurization
          13.3 Multiple pressurized enclosures with a common
                 safety device
          13.4 Purging
    14 Additional requirements for apparatus for use in
          Zone 2
          14.1 Degree of protection of enclosures (IEC 34-5
                 and IEC 529)
          14.2 Energy-limited apparatus and circuits
          14.3 Wiring systems
          14.4 Motors supplied at varying frequency and voltage
    15 Special applications (additional clause)
          15.1 Battery operated vehicles
          15.2 Personal electrical apparatus
    Annex A (normative) Verification of intrinsically safe
                        circuits with more than one associated
                        apparatus with linear current/voltage
                        characteristics
    Annex B (informative) Methods of determining the maximum
                          system voltages and currents in
                          intrinsically safe circuits with more
                          than one associated apparatus with
                          linear current/voltage characteristics
                          (as required by Annex A)
    Annex C (informative) Frictional sparking risks with light
                          metals and their alloys
    Annex D (informative) Determination of cable parameters
    Annex ZA (normative) Normative references to international
                         publications with their corresponding
                         European publications
    Bibliography

    Abstract - (Show below) - (Hide below)

    Gives requirements for design, selection and erection of electrical installations in explosive gas atmospheres, which are in addition to requirements for installations in non-hazardous areas. Applicable to all electrical equipment and installations in hazardous areas whether, temporary, permanent, portable, transportable or hand-held. Applicable to installations at all voltages.

    General Product Information - (Show below) - (Hide below)

    Committee EXL/31/3
    Document Type Standard
    Publisher British Standards Institution
    Status Withdrawn

    Standards Referenced By This Book - (Show below) - (Hide below)

    DEFSTAN 00-101(PT3)/2(2008) : 2008 DESIGN STANDARDS FOR EXPLOSIVES SAFETY IN MOD SHIPS AND SUBMARINES - PART 3: ELECTRICAL EQUIPMENT AND INSTALLATION
    EI TP PETROLEUM ROAD TANKER : 2010 PETROLEUM ROAD TANKER DESIGN AND CONSTRUCTION
    EI MODEL CODE SAFE PRACTICE PT1 : 2010 THE SELECTION, INSTALLATION, INSPECTION, AND MAINTENANCE OF ELECTRICAL AND NON ELECTRICAL APPARATUS IN HAZARDOUS AREAS

    Standards Referencing This Book - (Show below) - (Hide below)

    IEC 60079-1:2014 RLV Explosive atmospheres - Part 1: Equipment protection by flameproof enclosures "d"
    IEC 60079-10:2002 Electrical apparatus for explosive gas atmospheres - Part 10: Classification of hazardous areas
    IEC 60364-4-41:2005+AMD1:2017 CSV Low voltage electrical installations - Part 4-41: Protection for safety - Protection against electric shock
    IEC 60079-17:2013 Explosive atmospheres - Part 17: Electrical installations inspection and maintenance
    IEC 60332-1:1993 Tests on electric cables under fire conditions - Part 1: Test on a single vertical insulated wire or cable
    IEC 60079-18:2014 RLV Explosive atmospheres - Part 18: Equipment protection by encapsulation “m”
    IEC 60614-2-5:1992 Specifications for conduits for electrical installations - Part 2: Particular specifications for conduits - Section 5: Flexible conduits
    IEC 60079-5:2015 RLV Explosive atmospheres - Part 5: Equipment protection by powder filling "q"
    IEC 60050-426:2008 International Electrotechnical Vocabulary (IEV) - Part 426: Equipment for explosive atmospheres
    IEC 60079-11:2011 Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i"
    IEC 60529:1989+AMD1:1999+AMD2:2013 CSV Degrees of protection provided by enclosures (IP Code)
    IEC 60755:2017 General safety requirements for residual current operated protective devices
    IEC 60079-6:2015 Explosive atmospheres - Part 6: Equipment protection by liquid immersion "o"
    IEC 60079-0:2011 Explosive atmospheres - Part 0: Equipment - General requirements
    IEC 60060-1:2010 High-voltage test techniques - Part 1: General definitions and test requirements
    IEC 60079-15:2010 Explosive atmospheres - Part 15: Equipment protection by type of protection "n"
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective