• PD CLC/TR 50480:2011

    Current The latest, up-to-date edition.

    Determination of cross-sectional area of conductors and selection of protective devices

    Available format(s):  Hardcopy, PDF

    Language(s):  English

    Published date:  31-12-2012

    Publisher:  British Standards Institution

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    Foreword
    Introduction
    1 Scope
    2 Reference documents
    3 Symbols
    4 Parameters
    5 Characteristics of installations
    6 Characteristics of the supply source
    7 Characteristics of protective devices
    8 Protection against overload currents
    9 Determination of breaking capacity of protective devices
    10 Ability to withstand electro-dynamic stresses for busbar
       trunking systems
    11 Fault protection (protection against indirect contact)
    12 Verification of thermal stress in conductors
    13 Voltage drop
    Annex A - Conductor resistances
    Bibliography
    National Annex NA (informative) - UK National Practice

    Abstract - (Show below) - (Hide below)

    Pertains to low-voltage installations with a nominal system frequency of 50 Hz in which the circuits consist of insulated conductors, cables or busbar trunking systems.

    Scope - (Show below) - (Hide below)

    This Technical Report applies to low-voltage installations with a nominal system frequency of 50 Hz in which the circuits consist of insulated conductors, cables or busbar trunking systems.

    It defines the different parameters used for the calculation of the characteristics of electrical wiring systems in order to comply with rules of HD 384/HD 60364.

    These rules are mainly the following:

    • current-carrying capacities of the conductors;

    • characteristics of protective devices in regard to protection against overcurrent;

    • verification of thermal stress in conductors due to short-circuit current or earth fault current;

    • fault protection (protection against indirect contact) in TN systems and IT systems;

    • limitation of voltage drop;

    • verification of mechanical stresses during short-circuit in busbar trunking systems (BTS) according to EN 60439-2 or powertrack systems according to EN 61534 series.

    The calculations provided in this Technical Report are only applicable where the characteristics of the circuits are known.

    For the purpose of this document, when referring to Busbar Trunking Systems, Powertrack Systems are also considered.

    NOTE 1 Mechanical stress during short-circuit is covered by IEC 60865.

    NOTE 2 In general these calculations concern supply by HV/LV transformer, but they are also applicable to supply by LV/LV transformer and LV back-up generators.

    NOTE 3 Effects of harmonics currents are not covered by this document.

    This Technical Report is also applicable for checking the compliance of the results of calculations performed by software programs for calculation of cross-sectional area of insulated conductors, crosssectional area of cables and characteristics for selection of busbar trunking systems with HD 384/HD 60364.

    General Product Information - (Show below) - (Hide below)

    Committee JPEL/64
    Development Note Supersedes 12/30263668 DC. (12/2012)
    Document Type Standard
    Publisher British Standards Institution
    Status Current
    Supersedes

    Standards Referenced By This Book - (Show below) - (Hide below)

    BS 7671(2008) : 2018 REQUIREMENTS FOR ELECTRICAL INSTALLATIONS - IET WIRING REGULATIONS
    BS 7671(2008) : 2008 REQUIREMENTS FOR ELECTRICAL INSTALLATIONS - IET WIRING REGULATIONS

    Standards Referencing This Book - (Show below) - (Hide below)

    IEC 60364-5-54:2011 Low-voltage electrical installations - Part 5-54: Selection and erection of electrical equipment - Earthing arrangements and protective conductors
    IEC 60364-4-43:2008 Low-voltage electrical installations - Part 4-43: Protection for safety - Protection against overcurrent
    IEC 60228:2004 Conductors of insulated cables
    HD 60364-4-43:2010 Low-voltage electrical installations - Part 4-43: Protection for safety - Protection against overcurrent
    IEC 60724:2000+AMD1:2008 CSV Short-circuit temperature limits of electric cables with rated voltages of 1 kV (Um = 1,2 kV) and 3 kV (Um = 3,6 kV)
    IEC 60364-4-41:2005+AMD1:2017 CSV Low voltage electrical installations - Part 4-41: Protection for safety - Protection against electric shock
    EN 61439-1:2011 Low-voltage switchgear and controlgear assemblies - Part 1: General rules
    IEC 60439-2:2000+AMD1:2005 CSV Low-voltage switchgear and controlgear assemblies - Part 2: Particular requirements for busbar trunking systems (busways)
    IEC 60269-2:2013+AMD1:2016 CSV Low-voltage fuses - Part 2: Supplementary requirements for fuses for use by authorized persons (fuses mainly for industrial application) - Examples of standardized systems of fuses A to K
    IEC 60364-5-53:2001+AMD1:2002+AMD2:2015 CSV Electrical installations of buildings - Part 5-53: Selection and erection of electrical equipment - Isolation, switching and control
    HD 60364-4-41:2017/A11:2017 LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 4-41: PROTECTION FOR SAFETY - PROTECTION AGAINST ELECTRIC SHOCK
    EN 60228:2005 COR 2005 CONDUCTORS OF INSULATED CABLES
    IEC 60269-1:2006+AMD1:2009+AMD2:2014 CSV Low-voltage fuses - Part 1: General requirements
    IEC 60269-3:2010+AMD1:2013 CSV Low-voltage fuses - Part 3: Supplementary requirements for fuses foruse by unskilled persons (fuses mainly for household or similar applications) - Examples of standardized systems of fuses A to F
    IEC 60439-1:1999+AMD1:2004 CSV Low-voltage switchgear and controlgear assemblies - Part 1: Type-tested and partially type-tested assemblies
    EN 60439-1:1999/A1:2004 LOW VOLTAGE SWITCHGEAR AND CONTROLGEAR ASSEMBLIES - PART 1 - TYPE TESTED AND PARTIALLY TYPE TESTED ASSEMBLIES
    HD 384.5.54 : 200S1 ELECTRICAL INSTALLATION OF BUILDINGS - SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - EARTHING ARRANGEMENTS AND PROTECTIVE CONDUCTORS
    HD 60269-2:2013 Low-voltage fuses - Part 2: Supplementary requirements for fuses for use by authorized persons (fuses mainly for industrial application) - Examples of standardized systems of fuses A to K
    IEC 61439-1:2011 Low-voltage switchgear and controlgear assemblies - Part 1: General rules
    IEC 60947-2:2016 Low-voltage switchgear and controlgear - Part 2: Circuit-breakers
    EN 60947-2:2017 Low-voltage switchgear and controlgear - Part 2: Circuit-breakers
    HD 60269-3:2010/A1:2013 LOW-VOLTAGE FUSES - PART 3: SUPPLEMENTARY REQUIREMENTS FOR FUSES FOR USE BY UNSKILLED PERSONS (FUSES MAINLY FOR HOUSEHOLD AND SIMILAR APPLICATIONS) - EXAMPLES OF STANDARDIZED SYSTEMS OF FUSES A TO F
    EN 60439-2:2000/A1:2005 LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR ASSEMBLIES - PART 2: PARTICULAR REQUIREMENTS FOR BUSBAR TRUNKING SYSTEMS (BUSWAYS)
    IEC 60364-5-52:2009 Low-voltage electrical installations - Part 5-52: Selection and erection of electrical equipment - Wiring systems
    EN 60269-1:2007/A2:2014 LOW-VOLTAGE FUSES - PART 1: GENERAL REQUIREMENTS (IEC 60269-1:2006/A2:2014)
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective