• PD CLC/TS 50131-2-8:2012

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    Alarm systems. Intrusion and hold-up systems Intrusion detectors. Shock detectors

    Available format(s):  Hardcopy, PDF

    Superseded date:  31-12-2016

    Language(s):  English

    Published date:  30-06-2014

    Publisher:  British Standards Institution

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    Foreword
    Introduction
    1 Scope
    2 Normative references
    3 Terms, definitions and abbreviations
    4 Functional requirements
    5 Marking, identification and documentation
    6 Testing
    Annex A (normative) - Standard test material
    Annex B (normative) - Dimensions and requirements of
            the standardised Test Magnets
    Annex C (normative) - General Testing Matrix
    Annex D (normative) - Standard immunity glass pane
    Annex E (normative) - Spring operated Hammer
    Annex F (informative) - Example list of small tools
    Annex G (normative) - Minimum performance requirements
            gross and shock integration attack tests
    Annex H (normative) - Immunity test: Small objects
            hit sensitivity
    Annex I (normative) - Immunity test: Hard objects
            hit sensitivity
    Annex J (normative) - Immunity test: Static pressure
            sensitivity
    Annex K (normative) - Immunity test: Dynamic pressure
            sensitivity
    Bibliography
    National Annex NA (Informative) - Text of IS1 to
                      EN 50131-2-8:2012

    Abstract - (Show below) - (Hide below)

    Pertains to shock detectors installed in buildings to detect the shock or series of shocks due to a forcible attack through a physical barrier (for example doors or windows).

    Scope - (Show below) - (Hide below)

    This Technical Specification is for shock detectors installed in buildings to detect the shock or series of shocks due to a forcible attack through a physical barrier (for example doors or windows).

    It provides for security Grades 1-4 (see EN 50131-1), specific or non specific wired or wire-free detectors and uses Environmental Classes i-iv (see EN 50130-5).

    This Technical Specification does not include requirements for detectors intended to protect for example vaults and safes from penetration attacks from e.g. drilling, cutting or thermal lance.

    This Technical Specification does not include requirements for shock detectors intended for use outdoors.

    A detector shall fulfil all the requirements of the specified grade.

    Functions additional to the mandatory functions specified in this Technical Specification may be included in the detector, providing they do not adversely influence the correct operation of the mandatory functions.

    This Technical Specification does not apply to system interconnections.

    General Product Information - (Show below) - (Hide below)

    Committee GW/1/1
    Document Type Standard
    Publisher British Standards Institution
    Status Superseded
    Superseded By

    Standards Referencing This Book - (Show below) - (Hide below)

    EN 60068-2-75:2014 Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests
    IEC 60068-1:2013 Environmental testing - Part 1: General and guidance
    IEC 60404-8-1:2015 Magnetic materials - Part 8-1: Specifications for individual materials - Magnetically hard materials
    EN 60068-1:2014 Environmental testing - Part 1: General and guidance
    IEC 60404-14:2002 Magnetic materials - Part 14: Methods of measurement of the magnetic dipole moment of a ferromagnetic material specimen by the withdrawal or rotation method
    IEC 60529:1989+AMD1:1999+AMD2:2013 CSV Degrees of protection provided by enclosures (IP Code)
    IEC 60404-5:2015 RLV Magnetic materials - Part 5: Permanent magnet (magnetically hard) materials - Methods of measurement of magnetic properties
    EN 50131-1:2006/A2:2017 ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 1: SYSTEM REQUIREMENTS
    EN 50131-6:2017 Alarm systems - Intrusion and hold-up systems - Part 6: Power supplies
    IEC 60068-2-75:2014 Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests
    EN 60404-5:2015 Magnetic materials - Part 5: Permanent magnet (magnetically hard) materials - Methods of measurement of magnetic properties
    EN 50130-4:2011/A1:2014 ALARM SYSTEMS - PART 4: ELECTROMAGNETIC COMPATIBILITY - PRODUCT FAMILY STANDARD: IMMUNITY REQUIREMENTS FOR COMPONENTS OF FIRE, INTRUDER, HOLD UP, CCTV, ACCESS CONTROL AND SOCIAL ALARM SYSTEMS
    EN 60529:1991/AC:2016-12 DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015)
    EN 60404-14:2002 Magnetic materials - Part 14: Methods of measurement of the magnetic dipole moment of a ferromagnetic material specimen by the withdrawal or rotation method
    IEC 60068-2-52:2017 Environmental testing - Part 2-52: Tests - Test Kb: Salt mist, cyclic (sodium chloride solution)
    EN 50130-5:2011 ALARM SYSTEMS - PART 5: ENVIRONMENTAL TEST METHODS
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective