• PD IEC/TR 61000-1-4:2005

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    Electromagnetic compatibility (EMC) General - Historical rationale for the limitation of power-frequency conducted harmonic current emmissions from equipment, in the frequency range up to 2 kHz

    Available format(s):  Hardcopy, PDF

    Superseded date:  03-11-2023

    Language(s):  English

    Published date:  23-01-2006

    Publisher:  British Standards Institution

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    INTRODUCTION
    1 Scope
    2 Normative references
    3 Definitions
    4 General appraisal
    5 Acceptable provisions in standards related to regulatory
      legislation
    6 History of IEC 61000-3-2 and its predecessors
      6.1 Before 1960
      6.2 1960 to 1975
      6.3 1975 to 1982
      6.4 1982 to 1995
      6.5 1995 to 2000
      6.6 The 'Millennium Amendment'
      6.7 Future development of IEC 61000-3-2
    7 History of IEC 61000-3-12 and its predecessor
      7.1 1989 to 1998
      7.2 After 1998
    8 Economic considerations taken into account in setting
      limits in IEC 61000-3-2 before publication in 1995, and
      before the finalization of the text of the Millennium
      Amendment
    Annex A (informative) Compatibility level and compensation
                          factor
    Annex B (informative) Comparison of Class A limits and the
                          harmonic spectra of phase-controlled
                          dimmers of incandescent lamps at
                          90 degree firing angle
    Annex C (informative) Comparison of Class C (Table 2 of
                          IEC 61000-3-2) limits and the harmonic
                          spectrum of a discharge lamp with
                          inductive ballast
    Annex D (informative) Comparison of Class D limits and the
                          harmonic spectra of capacitor-filtered
                          single-phase rectifiers with 35 degree
                          and 65 degree conduction angles
    Annex E (informative) Economic considerations taken into
                          account in setting limits, before
                          finalization of the text of the
                          Millennium Amendment to IEC 61000-3-2
    Annex F (Informative) Concept plan for the full revision of
                          IEC 61000-3-2
    Annex G (informative) Derivation of the limits in IEC 61000-3-12
    Annex H (informative) Explanation of the reasons for using the
                          concepts of total harmonic distortion
                          distortion (PWHD)
    Bibliography

    Abstract - (Show below) - (Hide below)

    Provides the sources and effects of power frequency conducted harmonic current emissions in the frequency range up to 2 kHz on the public electricity supply, and gives an account of the reasoning and calculations leading to the existing emission limits for equipment in the editions of IEC 61000-3-2, up to and including the second edition (2000) and its first amendment (2001), and in the first edition of IEC 61000-3-12 (2004).

    Scope - (Show below) - (Hide below)

    This part of IEC 61000, which is an IEC technical report, reviews the sources and effects of power frequency conducted harmonic current emissions in the frequency range up to 2 kHz on the public electricity supply, and gives an account of the reasoning and calculations leading to the existing emission limits for equipment in the editions of IEC 61000-3-2, up to and including the second edition (2000) and its first amendment (2001), and in the first edition of IEC 61000-3-12 (2004).

    The concepts in this technical report apply to all low voltage AC systems, but the numerical values apply specifically to the European 230 V/400 V 50 Hz system.

    NOTE A rationale for the limits in future complete revisions of IEC 61000-3-2 or IEC 61000-3-12 or both will be included in a new technical report.

    General Product Information - (Show below) - (Hide below)

    Committee GEL/210
    Development Note Supersedes 01/204271 DC. (02/2006)
    Document Type Standard
    Publisher British Standards Institution
    Status Superseded
    Superseded By
    Supersedes

    Standards Referencing This Book - (Show below) - (Hide below)

    IEC 61000-3-11 : 2.0 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 3-11: LIMITS - LIMITATION OF VOLTAGE CHANGES, VOLTAGE FLUCTUATIONS AND FLICKER IN PUBLIC LOW-VOLTAGE SUPPLY SYSTEMS - EQUIPMENT WITH RATED CURRENT <= 75 A AND SUBJECT TO CONDITIONAL CONNECTION
    IEC 61000-3-12:2011 Electromagnetic compatibility (EMC) - Part 3-12: Limits - Limits for harmonic currents produced by equipment connected to public low-voltage systems with input current >16 A and ≤ 75 A per phase
    IEC TS 61000-3-4:1998 Electromagnetic compatibility (EMC) - Part 3-4: Limits - Limitation of emission of harmonic currents in low-voltage power supply systems for equipment with rated current greater than 16 A
    IEC 61000-2-2:2002+AMD1:2017 CSV Electromagnetic compatibility (EMC) - Part 2-2: Environment - Compatibility levels for low-frequency conducted disturbances and signalling in public low-voltage power supply systems
    IEC 61000-3-3:2013 RLV Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection
    IEC 61000-3-3 : 3.0EN+(REDLINE+VERSION) ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 3-3: LIMITS - LIMITATION OF VOLTAGE CHANGES, VOLTAGE FLUCTUATIONS AND FLICKER IN PUBLIC LOW-VOLTAGE SUPPLY SYSTEMS, FOR EQUIPMENT WITH RATED CURRENT <= 16 A PER PHASE AND NOT SUBJECT TO CONDITIONAL CONNECTION
    IEC 61000-4-13:2002+AMD1:2009+AMD2:2015 CSV Electromagnetic compatibility (EMC) - Part 4-13: Testing and measurement techniques - Harmonics and interharmonics includingmains signalling at a.c. power port, low frequency immunity tests
    IEC 61000-3-2 : 4.0 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 3-2: LIMITS - LIMITS FOR HARMONIC CURRENT EMISSIONS (EQUIPMENT INPUT CURRENT <= 16 A PER PHASE)
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective