    Table of Contents - (Show below) - (Hide below)

    Preface
    1 Scope
    2 References and definitions
    3 Quality assurance
    4 Electrical characteristics
    5 Electrical connection and designation
    6 Bushings and terminals
    7 Off-circuit tap changer and voltage selector switches
    8 Mechanical characteristics
    9 Tests
    10 Markings
    11 Optional items

    Abstract - (Show below) - (Hide below)

    Specifies the requirements for distribution transformers intended primarily for operation by electric utilities.

    Scope - (Show below) - (Hide below)

    Preface This is the first edition of CSA C2.2, Pole-mounted, single-phase distribution transformers for electric utilities.? Scope 1.1 This Standard specifies the requirements for distribution transformers intended primarily for operation by electric utilities. Note: The operation of transformers complying with this Standard by other than an electric utility can be subject to additional requirements by the electrical inspection authority having jurisdiction.? 1.2 This Standard applies to single-phase, single-bushing, 60 Hz distribution transformers suitable for direct pole mounting and designed for operation on an effectively grounded wye system, Type ONAN, rated at 167 kV.A or below, with an insulation class of 25 kV or less.? 1.3 This Standard includes voltage ratings, kV.A ratings, certain mechanical characteristics, and test procedures. Also included are the following performance characteristics: energy efficiency (by reference to CAN/CSA-C802.1), temperature rise, loading capabilities, sound level, and radio influence voltage (RIV).? 1.4 The requirements for self-protected transformers are not covered by this Standard.? 1.5 This Standard does not apply to auto-, testing, dry-type, welding, furnace, rectifier, network, pad-mounted, subway-type, or special-purpose transformers, or to step-voltage regulators.? 1.6 In CSA Standards, \"shall\" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; \"should\" is used to express a recommendation or that which is advised but not required; \"may\" is used to express an option or that which is permissible within the limits of the standard; and \"can\" is used to express possibility or capability. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.

    General Product Information - (Show below) - (Hide below)

    Document Type Standard
    Product Note Reconfirmed EN
    Publisher Canadian Standards Association
    Status Current

    Standards Referencing This Book - (Show below) - (Hide below)

    W59-13 Welded steel construction (metal arc welding)
    CSA C802.1 : 2013 MINIMUM EFFICIENCY VALUES FOR LIQUID-FILLED DISTRIBUTION TRANSFORMERS
    ASTM D 1816 : 2012 : REDLINE Standard Test Method for Dielectric Breakdown Voltage of Insulating Liquids Using VDE Electrodes
    CAN/CSA-C50-14 (R2018) Mineral insulating oil, electrical, for transformers and switches
    IEEE C57.12.35-2013 IEEE Standard Bar Coding for Distribution Transformers and Step-Voltage Regulators
    IEEE C57.91-2011 REDLINE IEEE Guide for Loading Mineral-Oil-Immersed Transformers and Step-Voltage Regulators
    IEEE C57.12.90-2010 IEEE Standard Test Code for Liquid-Immersed Distribution, Power, and Regulating Transformers
    CSA C22.2 No. 0.15 : 2015 ADHESIVE LABELS
    IEEE C57.12.20-2011 REDLINE IEEE Standard for Overhead-Type Distribution Transformers 500 kVA and Smaller: High Voltage, 34 500 V and Below; Low Voltage, 7970/13 800Y V and Below
    IEEE C57.12.31-2010 IEEE Standard for Pole-Mounted Equipment--Enclosure Integrity
    CSA ISO 9001 : 2016 QUALITY MANAGEMENT SYSTEMS - REQUIREMENTS
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective