• CAN/CSA-C50052-99 (R2016)

    Current The latest, up-to-date edition.

    Cast Aluminium Alloy Enclosures for Gas-Filled High-Voltage Switchgear and Controlgear (Adopted CENELEC Standard EN 50052:1986 including Amendments A1:1990 and A2:1993, with Canadian deviations)

    Available format(s):  Hardcopy, PDF

    Language(s):  English, French

    Published date:  01-01-1999

    Publisher:  Canadian Standards Association

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    0 Introduction
    1 Scope
    2 Quality assurance
    3 Definitions
    4 Materials
       4.1 Selection of material
       4.2 Chemical analysis
    5 Design
       5.1 General
       5.2 Corrosion allowance
       5.3 Design stresses
       5.4 Calculation methods
       5.5 Manholes and inspection openings
    6 Manufacture and workmanship
       6.1 Manufacture
       6.2 Consultation between manufacturer and founder
       6.3 Foundry technique
       6.4 Geometry and dimensions
       6.5 Chemical composition and mechanical properties
       6.6 Workmanship
    7 Repair of casting defects
       7.1 General
       7.2 Repair by welding
       7.3 Impregnation of castings
    8 Heat treatment
       8.1 Heat treatment procedure
       8.2 Methods of heating
       8.3 Quenching
       8.4 Calibration of furnace temperature
       8.5 Heat treatment charts
    9 Inspection, testing and certification
       9.1 Proof tests
       9.2 Inspection and routine tests
       9.3 Certification
    10 Pressure relief devices
       10.1 General
       10.2 Bursting discs
       10.3 Self-closing pressure relief valves
       10.4 Non-self-closing pressure relief devices
    Table
    Figure
    Annex
    A Welder performance test

    Abstract - (Show below) - (Hide below)

    Applicable to cast aluminium alloy enclosures pressurized with dry air, inert gases, for example, sulphur hexafluoride, carbon tetrafluoride, or nitrogen or a mixtures of these gases, used in indoor or outdoor installations of high-voltage switchgear and control gear, where the gas is used principally for its dielectric and/or arc-quenching properties, with rated voltages: (a) 1 kV and up to and including 52 kV and with gas-filled compartments with design pressure greater than 3 bar (gauge); and (b) 72.5 kV and above.

    Scope - (Show below) - (Hide below)

    Scope This Standard applies to cast aluminium alloy enclosures pressurized with dry air, inert gases, eg. sulphur hexafluoride, carbon tetrafluoride, or nitrogen or a mixture of such gases, used in indoor or outdoor installations of high-voltage switchgear and controlgear, where the gas is used principally for its di electric and/or arc-quenching properties, with rated voltages (1) 1 kV and up to and including 52 kV and with gas-filled compartments with design pressure greater than 3 bar (gauge); and (2) 72.5 kV and above. The enclosures comprise parts of electrical equipment not necessarily limited to the following examples: Circuit-breakers Switch-disconnectors Disconnectors Earthing switches Current transformers Voltage transformers Surge arresters Busbars and connections The scope also covers pressurized components such as the center chamber of live tank switchgear, gas-insulated current transformers, etc.

    General Product Information - (Show below) - (Hide below)

    Document Type Standard
    Product Note Reconfirmed EN
    Publisher Canadian Standards Association
    Status Current
    Supersedes
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective