• CSA C22.2 No. 18 : 0

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    OUTLET BOXES, CONDUIT BOXES, FITTINGS AND ASSOCIATED HARDWARE

    Available format(s):  Hardcopy, PDF

    Superseded date:  16-02-2004

    Language(s):  English

    Published date: 

    Publisher:  Canadian Standards Association

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    Contents
    Preface
    Foreword
    1. Scope
    2. Definitions
    3. General Requirements and Reference Publications
    3.1 General
    3.2 Reference Publications
    4. Construction-Boxes, Covers, Bar Hangers, and
        Fittings
    4.1 General
    4.2 Boxes
    4.2.1 Materials
    4.2.2 Dimensions
    4.2 3 Knockouts of Boxes
    4.2.4 Openings for Conduit and EMT
    4.2.5 Closure of Openings
    4.2.6 Integral Clamps or Fasteners
    4.2.7 Rain-Tight Boxes (Type 3R)
    4.2.8 Ceiling Fan Support Boxes
    4.2.9 Bonding and Grounding
    4.2.10 Box Supports and Studs
    4.3 Outlet Box Covers
    4.3.1 Metallic Materials
    4.3.2 Nonmetallic Materials
    4.3.3 Covers for Nonmetallic Boxes
    4.3.4 Materials for Bell Transformers etc
    4.3.5 Holes in Outlet Box Covers
    4.3.6 Volume
    4.4 Bar Hangers
    4.4.1 Ceiling Installations
    4.4.2 Wall Installation
    4.5 Protection Against Corrosion (Boxes, Covers, and Bar
         Hangers)
    4.6 Fittings
    4.6.1 General
    4.6.2 Metallic Materials
    4.6.3 Nonmetallic Materials
    4.6.4 Environment Considerations
    4.7 Electrical Metallic Tubing and Threadless Rigid
         Conduit Fittings
    4.7.1 Dimensions
    4.7.2 End Stops
    4.7.3 Requirements
    4.8 Service Entrance Fittings
    4.8.1 Requirements
    4.9 Fittings and Clamps for Nonmetallic Sheath Cable
    4.9.1 Requirements
    4.10 Fittings and Clamps for Armoured Cable, Aluminium
         Sheathed Cable, Flexible Metal Conduit, and
         Liquid-Tight Conduit
    4.10.1 General
    4.10.2 Dimensions
    4.10.3 Requirements
    4.11 Mesh Grips
    4.11.1 General
    4.11.2 Materials
    4.11.3 Requirements
    4.12 Entrance Caps
    4.12.1 Requirements
    4.12.2 Nonmetallic Materials
    4.13 Locknuts
    4.13.1 General
    4.13.2 Dimensions
    4.14 Bushings and Nipples for Rigid Conduit
    4.14.1 General
    4.14.2 Dimensions
    4.14.3 Requirements
    4.15 Reducing Washers
    4.15.1 General
    4.16 Straps for Rigid Conduit and Electrical Metallic
         Tubing
    4.16.1 General
    4.16.2 Requirements
    4.17 Straps and Staples for Arnoured Cable, Flexible
         Metal Conduit, and Nonmetallic Sheathed Cable
    4.17.1 General
    4.17.2 Dimensions
    4.17.3 Requirements
    4.18 Hangers for Rigid Conduit and Electrical Metallic
         Tubing
    4.18.1 Requirements
    4.19 Protector Plates
    4.19.1 Dimensions
    4.20 Armoured Cable Bushings
    4.20.1 Dimensions
    4.20.2 Requirements
    4.21 Tray Cable and Flexible Cord Fittings
    4.22 Bushings and Standoffs for Nonmetallic Sheathed
         Cables
    5. Marking
    5.1 General
    5.2 Boxes and Raised Covers
    5.3 Rain-Tight Boxes (or Suitable For Use in Wet
         Locations)
    5.4 Fittings
    5.5 EMT Fittings
    5.6 Fittings, Dry Locations
    5.7 Clamps for Cable and Conduit
    5.8 Hardware Items (Staples, Hangers, Locknuts,
         Reducing Washers, Protector Plates, etc)
    5.9 Insulating Bushings
    5.10 Armoured Cable Bushings
    5.11 Mesh Grips
    5.12 Bushings and Standoffs for Nonmetallic Sheathed
         Cables
    6. Tests
    6.1 Strength of Fastening of Boxes
    6.2 Boxes with Attached Device-Mounting Straps
    6.3 Nonmetallic Box Materials
    6.3.1 Flammability
    6.3.2 Impact
    6.3.3 Crushing
    6.3.4 Ageing
    6.3.5 Mould Stress Relief
    6.3.6 Elevated Temperature Pullout and Distortion
    6.4 Secureness of Bonding Screw in a Nonmetallic Box
    6.5 Ceiling Fan Support Boxes
    6.6 Volume Measurement of Boxes and Raised Covers
    6.7 Knockouts
    6.7.1 Strength of Knockouts
    6.7.2 Flat Surface Surrounding Knockouts Near a Radius
    6.7.3 Knockouts (Pryouts Including Breakouts) of Boxes
          of Nonmetallic Material
    6.8 Nonmetallic Plug of Other Closure
    6.9 Thickness of Protective Metallic Coating of Boxes
         and Covers
    6.10 Stud and Attachment to a Box or Cover
    6.11 Box Supports
    6.12 Bar Hangers
    6.13 Rain-Tight (or Suitable for Use in Wet Locations)
         Boxes and Fittings
    6.13.1 Boxes
    6.13.2 Fittings
    6.14 Elastomeric Bushings and Glands, Accelerated Ageing
    6.15 Fittings and Clamps for Flexible Metal Conduit,
         Armoured Cable, Aluminium Sheathed Cable
    6.15.1 Resistance
    6.15.2 Pullout
    6.16 Clamps and Fittings for Nonmetallic Sheathed Cable
    6.16.1 Pullout
    6.16.2 Temperature
    6.16.3 Moulded Nonmetallic Clamps and Fittings
    6.17 Threadless Fittings for Electrical Metallic Tubing
         and Rigid Conduit
    6.17.1 Internal Diameter
    6.17.2 Resistance, Bending, and Pullout
    6.17.3 Cantilever
    6.17.4 Fittings with Locknuts
    6.18 Submersible Fitting
    6.19 Concrete-Tight Fitting
    6.20 Service Entrance Cable Fitting Pullout
    6.21 Nonmetallic and Insulated Metallic Bushings
    6.22 Straps for Rigid Conduit and Electrical Metallic
         Tubing
    6.23 Straps and Staples for Armoured Cable, Flexible
         Metal Conduit, and Nonmetallic Sheathed Cable
    6.24 Hangers for Rigid Conduit and Electrical Metallic
         Tubing
    6.25 Fittings for Liquid-Tight Flexible Metal or
         Nonmetallic Conduit
    6.26 Armoured Cable Bushings
    6.26.1 Deterioration and Flexibility
    6.26.2 Low Temperature Flexibility
    6.26.3 Dielectric Strength
    6.27 Fittings-Screw Torque
    6.28 Mesh Grips
    6.28.1 Tension
    6.28.2 Abrasion
    6.28.3 Accelerated Ageing
    6.29 Fittings for Flexible Cord
    6.29.1 Strain Relief
    6.29.2 Hosedown (Fittings Intended for Type 4 and 4X
           Enclosures)
    6.29.3 Hosedown (Fittings Intended for Type 3 and 3S
           Enclosures)
    6.29.4 Resistance to Impact at Low Temperature
    6.30 Fittings for Tray Cable
    6.30.1 Pull
    6.30.2 Oven Conditioning
    6.30.3 Weather Resistance
    6.30.4 Dielectric Strength
    6.30.5 Oil Immersion
    6.31 Bushings and Standoffs for Nonmetallic Sheathed
         Cables
    6.31.3 Oven Conditioning
    6.31.2 Voltage Withstand
    6.31.3 Secureness
    6.32 Wire Pull Test for Angle Fitting, Conduit Body, and
         Short-Radius Conduit Body
    6.33 Test on Expanded (Foam) Closed-Cell Materials
    6.34 Expansion Fittings (for Rigid Metal Conduit)
    6.35 Hubs
    Tables
    Figures
    Appendices
    A-Recommended Bushing Size for a Given Range of Armour
    B-Test Guides
    C-Marking Translations
    D-Markings for Specific Conditions of Use

    Abstract - (Show below) - (Hide below)

    Applicable to products that are designed to be employed in accordance with the rules of the Canadian Electrical Code, Part I.

    General Product Information - (Show below) - (Hide below)

    Document Type Standard
    Publisher Canadian Standards Association
    Status Superseded

    Standards Referenced By This Book - (Show below) - (Hide below)

    C22.2 NO. 62-93 (R2017) Surface Raceway Systems
    CSA E61558.2.5 : 2003 : R2017 SAFETY OF POWER TRANSFORMERS, POWER SUPPLY UNITS AND SIMILAR - PART 2-5: PARTICULAR REQUIREMENTS FOR SHAVER TRANSFORMERS AND SHAVER SUPPLY UNITS
    SAE J 2698 : 2014 PRIMARY SINGLE PHASE NOMINAL 120 VAC WIRING DISTRIBUTION ASSEMBLY DESIGN - TRUCK AND BUS
    CSA C22.2 No. 62 : 1993 : R2008 SURFACE RACEWAY SYSTEMS
    CSA C22.2 No. 184.1 : 2015 SOLID-STATE DIMMING CONTROLS
    CSA C22.2 No. 111 : 2010 : R2015 GENERAL-USE SNAP SWITCHES
    CSA C22.2 No.111 : 2010 GENERAL-USE SNAP SWITCHES
    CSA C22.2 No. 111 : 2010 : INC : UPD 1 : 2012 GENERAL-USE SNAP SWITCHES
    NEMA UC 2:1993 (R2000, R2005, R2010, R2015) UNDERCARPET POWER DISTRIBUTION SYSTEMS
    CSA C22.2 No. 217 : 0 RADIANT SPACE HEATING PANELS, PANEL SETS, AND SYSTEMS
    CSA C22.2 No. 94 : 1991 : R2006 SPECIAL PURPOSE ENCLOSURES
    CSA C22.2 No. 63 : 1993 HOUSEHOLD REFRIGERATORS AND FREEZERS
    CSA C22.2 No. 63 : 1993 : INC : UPD 6 : 2012 : R200800 HOUSEHOLD REFRIGERATORS AND FREEZERS
    CSA C22.2 No. 144 : 1991 : R2006 GROUND FAULT CIRCUIT INTERRUPTERS
    CSA C22.2 No. 144.1 : 2016 GROUND-FAULT CIRCUIT-INTERRUPTERS
    CSA C22.2 No. 66.1 : 2006 : INC : UPD 2 : 2013 : R201100 LOW VOLTAGE TRANSFORMERS - PART 1: GENERAL REQUIREMENTS
    CSA C22.2 No. 66.1 : 2006 : INC : UPD 1 : 2012 : R201100 LOW VOLTAGE TRANSFORMERS - PART 1: GENERAL REQUIREMENTS
    UL 1472:2ED 2015-09 Solid-State Dimming Controls
    UL 943:5ED 2016-05 Ground-Fault Circuit-Interrupters
    CSA C22.2 No. 66.1 : 2006 : R2011 LOW VOLTAGE TRANSFORMERS - PART 1: GENERAL REQUIREMENTS
    CSA C22.2 No. 66.1 : 2006 LOW VOLTAGE TRANSFORMERS - PART 1: GENERAL REQUIREMENTS
    CSA C22.2 No. 66.1 : 2006 : R2015 LOW VOLTAGE TRANSFORMERS - PART 1: GENERAL REQUIREMENTS
    CSA T525 : 0 RESIDENTIAL WIRING FOR TELECOMMUNICATIONS
    CSA C22.2 No. 255 : 2004 NEON TRANSFORMERS AND POWER SUPPLIES
    CSA C22.2 No. 144 : 1991 : R2011 GROUND FAULT CIRCUIT INTERRUPTERS
    CSA E61558.2.5 : 2003 SAFETY OF POWER TRANSFORMERS, POWER SUPPLY UNITS AND SIMILAR - PART 2-5: PARTICULAR REQUIREMENTS FOR SHAVER TRANSFORMERS AND SHAVER SUPPLY UNITS
    CSA C22.2 No. 254 : 2005(R2015) MOTOR CONTROL CENTRES
    CSA C22.2 No. 94 : 1991 : R2011 SPECIAL PURPOSE ENCLOSURES
    CSA C22.2 No. 63 : 1993 : R2013 HOUSEHOLD REFRIGERATORS AND FREEZERS
    CSA C22.2 No. 144 : 1991 GROUND FAULT CIRCUIT INTERRUPTERS
    CSA C22.2 No. 66 : 0 SPECIALITY TRANSFORMERS
    CSA C22.2 No. 62 : 1993 : R2013 SURFACE RACEWAY SYSTEMS
    CSA C22.2 No. 255 : 2004 : R2014 NEON TRANSFORMERS AND POWER SUPPLIES
    CSA E61558.2.5 : 2003 : R2012 SAFETY OF POWER TRANSFORMERS, POWER SUPPLY UNITS AND SIMILAR - PART 2-5: PARTICULAR REQUIREMENTS FOR SHAVER TRANSFORMERS AND SHAVER SUPPLY UNITS
    CSA C22.2 No. 144 : 1991 : R2015 GROUND FAULT CIRCUIT INTERRUPTERS
    CSA C22.2 No. 62 : 1993 SURFACE RACEWAY SYSTEMS

    Standards Referencing This Book - (Show below) - (Hide below)

    C22.1-15 Canadian Electrical Code, Part I (23rd Edition), Safety Standard for Electrical Installations
    CSA C22.2 No. 0.5 : 2016 THREADED CONDUIT ENTRIES
    CSA C22.2 No. 65 : 2013 WIRE CONNECTORS
    CSA C22.2 No. 56 : 2013 FLEXIBLE METAL CONDUIT AND LIQUID-TIGHT FLEXIBLE METAL CONDUIT
    CSA C22.2 NO. 85:14 (R2018) Rigid PVC boxes and fittings
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective