• C22.2 NO. 31-18

    Current The latest, up-to-date edition.

    Switchgear assemblies

    Available format(s):  Hardcopy, PDF

    Language(s):  English

    Published date:  01-01-2018

    Publisher:  Canadian Standards Association

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    Preface
    1 Scope
    2 Reference publications
    3 Definitions
    4 Construction
    5 Marking
    6 Tests
    7 Low-voltage switchgear assemblies
    8 High-voltage switchgear assemblies
    Annex A (Normative) - French translations of cautions, warnings,
            and safety instructions
    Annex B (Informative) - Method of measurement of spacings
            when insulating barriers are used
    Annex C (Normative) - Impulse testing
    Annex D (Informative) - Guide to the measurement of corona in
            switchgear assemblies
    Annex E (Informative) - Method for conducting temperature tests
    Annex F (Normative) - Pressurized gas insulated switchgear
    Annex G (Informative) - Tightness of pressurized gas insulated
            switchgear
    Annex H (Informative) - Illustration of defined terms 'unit'
            and 'compartment'

    Abstract - (Show below) - (Hide below)

    Pertains to deadfront indoor enclosed and outdoor enclosed assemblies of switchgear devices such as: a) switches; b) interrupting devices; c) air circuit breakers; d) power circuit breakers; and e) control, metering, protective, and regulating equipment with associated interconnections and supporting structures.

    Scope - (Show below) - (Hide below)

    Preface This is the eleventh edition of CSA C22.2 No. 31, Switchgear assemblies . It supersedes previous editions, published in 2014, 2010, 2004, 1989, 1983, 1977, 1972, 1965, 1958, and 1939. It is one of a series of Standards issued by CSA Group under Part II of the Canadian Electrical Code. For general information on the Standards of the Canadian Electrical Code, Part II, see the Preface of CAN/CSA-C22.2 No. 0. The applicable requirements of CSA TIL D-06 are incorporated in this Standard. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope 1.1 This Standard applies to deadfront indoor enclosed and outdoor enclosed assemblies of switchgear devices such as a) switches; b) interrupting devices; c) air circuit breakers; d) power circuit breakers; and e) control, metering, protective, and regulating equipment with associated interconnections and supporting structures. 1.2 This Standard covers equipment with a nominal voltage of 46 kV or less that is intended to be used a) in accordance with the Canadian Electrical Code, Part I; b) in non-hazardous locations; c) for controlling and protecting the power from generators or other sources; and d) for supplying electrical energy to power and lighting circuits. 1.3 This Standard does not apply to panelboards, industrial control equipment, switchboards for communication circuits, or low-voltage assemblies consisting of separately supported enclosed switches, enclosed circuit breakers, and possibly service meters, with interconnection between them enclosed in raceways. Note: Manufacturers and installers of switchgear assemblies approved under this Standard should take due note of the Canadian Electrical Code, Part I, with respect to the location of switchgear devices in areas where certain components might not be acceptable. 1.4 Clauses 2 to 6 apply to all switchgear assemblies and are supplemented and amended by a) Clause 7 for low-voltage switchgear assemblies; and b) Clause 8 for high-voltage switchgear assemblies. 1.5 In this Standard, \"shall\" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; \"should\" is used to express a recommendation or that which is advised but not required; and \"may\" is used to express an option or that which is permissible within the limits of the standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (nonmandatory) to define their application.

    General Product Information - (Show below) - (Hide below)

    Document Type Standard
    Publisher Canadian Standards Association
    Status Current
    Supersedes

    Standards Referencing This Book - (Show below) - (Hide below)

    IEC 60480:2004 Guidelines for the checking and treatment of sulfur hexafluoride (SF6) taken from electrical equipment and specification for its re-use
    IEC 62271-100:2008+AMD1:2012+AMD2:2017 CSV High-voltage switchgear and controlgear - Part 100: Alternating-current circuit-breakers
    IEEE C37.20.1-2015 REDLINE IEEE Standard for Metal-Enclosed Low-Voltage (1000 Vac and below, 3200 Vdc and below) Power Circuit Breaker Switchgear
    CSA C22 NO. 4 : 2016 ENCLOSED AND DEAD-FRONT SWITCHES
    IEC 62271-200:2011 High-voltage switchgear and controlgear - Part 200: AC metal-enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV
    CSA C22.2 No. 5 : 2013 MOLDED-CASE CIRCUIT BREAKERS, MOLDED-CASE SWITCHES AND CIRCUIT-BREAKER ENCLOSURES
    C22.1-15 Canadian Electrical Code, Part I (23rd Edition), Safety Standard for Electrical Installations
    ANSI C37.51 : 1989 SWITCHGEAR - METAL-ENCLOSED LOW-VOLTAGE AC POWER - CIRCUIT BREAKER SWITCHGEAR ASSEMBLIES - CONFORMANCE TEST PROCEDURES
    IEEE C37.20.2-2015 IEEE Standard for Metal-Clad Switchgear
    IEC 60376:2005 Specification of technical grade sulfur hexafluoride (SF6) for use in electrical equipment
    CSA C22.2 No. 178.1 : 2014 TRANSFER SWITCH EQUIPMENT
    IEC 60085:2007 Electrical insulation - Thermal evaluation and designation
    IEEE 4-2013 IEEE Standard for High-Voltage Testing Techniques
    IEEE C37.20.3-2013 REDLINE IEEE Standard for Metal-Enclosed Interrupter Switchgear (1 kV-38 kV)
    IEEE C37.13-2015 REDLINE IEEE Standard for Low-Voltage AC Power Circuit Breakers Used in Enclosures
    IEC 60068-2-17:1994 Basic environmental testing procedures - Part 2-17: Tests - Test Q: Sealing
    IEC TR 60943:1998+AMD1:2008 CSV Guidance concerning the permissible temperature rise for parts of electrical equipment, in particular for terminals
    ASTM D 2472 : 2015 : REDLINE Standard Specification for Sulfur Hexafluoride
    ASTM G 155 : 2013 : REDLINE Standard Practice for Operating Xenon Arc Light Apparatus for Exposure of Non-Metallic Materials
    IEC 62271-1:2017 High-voltage switchgear and controlgear - Part 1: Common specifications for alternating current switchgear and controlgear
    IEEE C37.16-2009 REDLINE IEEE Standard for Preferred Ratings,Related Requirements, and Application Recommendations for Low-Voltage AC (635 V and below)and DC (3200 V and below) Power Circuit Breakers
    ASTM D 1868 : 2013 : REDLINE Standard Test Method for Detection and Measurement of Partial Discharge (Corona) Pulses in Evaluation of Insulation Systems
    IEC 61439-1:2011 Low-voltage switchgear and controlgear assemblies - Part 1: General rules
    IEEE C37.12-2008 REDLINE IEEE Guide for Specifications of High-Voltage Circuit Breakers (over 1000 Volts)
    IEC 60947-2:2016 Low-voltage switchgear and controlgear - Part 2: Circuit-breakers
    IEEE C57.12.28-2014 IEEE Standard for Pad-Mounted Equipment--Enclosure Integrity
    CSA C22.2 No. 94.2 : 2015 ENCLOSURES FOR ELECTRICAL EQUIPMENT, ENVIRONMENTAL CONSIDERATIONS
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective