• CSA C22.2 NO. 60079-28:16 (R2021)

    Current The latest, up-to-date edition.

    Explosive atmospheres — Part 28: Protection of equipment and transmission systems using optical radiation (Adopted IEC 60079-28:2015, second edition, 2015-05, with Canadian deviations) | Atmosphères explosives — Partie 28 : Protection du matériel et des systèmes de transmission utilisant le rayonnement optique (norme IEC 60079-28: 2015 adoptée, deuxième édition, 2015-05, avec exigences propres au Canada)

    Available format(s):  Hardcopy, PDF

    Language(s):  English - French

    Published date:  01-01-2016

    Publisher:  Canadian Standards Association

    Add To Cart

    Abstract - (Show below) - (Hide below)

    CSA Preface This is the first edition of CAN/CSA-C22.2 No. 60079-28, Explosive atmospheres — Part 28: Protection of equipment and transmission systems using optical radiation, which is an adoption, with Canadian deviations, of the identically titled IEC (International Electrotechnical Commission) Standard 60079-28 (second edition, 2015-05). It is one in a series of Standards issued by CSA Group under Part II of the Canadian Electrical Code. For brevity, this Standard will be referred to as \"CAN/CSA-C22.2 No. 60079-28\" throughout. This Standard is intended to be used in conjunction with CAN/CSA-C22.2 No. 60079-0, Explosive atmospheres — Part 0: Equipment — General requirements. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope This part of IEC 60079 specifies the requirements, testing and marking of equipment emitting optical radiation intended for use in explosive atmospheres. It also covers equipment located outside the explosive atmosphere or protected by a Type of Protection listed in IEC 60079-0, but which generates optical radiation that is intended to enter an explosive atmosphere. It covers Groups I, II and III, and EPLs Ga, Gb, Gc, Da, Db, Dc, Ma and Mb. This standard contains requirements for optical radiation in the wavelength range from 380 nm to 10 μm. It covers the following ignition mechanisms: • Optical radiation is absorbed by surfaces or particles, causing them to heat up, and under certain circumstances this may allow them to attain a temperature which will ignite a surrounding explosive atmosphere. • In rare special cases, direct laser induced breakdown of the gas at the focus of a strong beam, producing plasma and a shock wave both eventually acting as ignition source. These processes can be supported by a solid material close to the breakdown point. NOTE 1 See a) and d) of the introduction. This standard does not cover ignition by ultraviolet radiation and by absorption of the radiation in the explosive mixture itself. Explosive absorbers or absorbers that contain their own oxidizer as well as catalytic absorbers are also outside the scope of this standard. This standard specifies requirements for equipment intended for use under atmospheric conditions. This standard supplements and modifies the general requirements of IEC 60079-0. Where a requirement of this standard conflicts with a requirement of IEC 60079-0, the requirement of this standard takes precedence. This standard applies to optical fibre equipment and optical equipment, including LED and laser equipment, with the exception of the equipment detailed below: 1) Non-array divergent LEDs used for example to show equipment status or backlight function. 2) All luminaires (fixed, portable or transportable), hand lights and caplights; intended to be supplied by mains (with or without galvanic isolation) or powered by batteries: – with continuous divergent light sources (for all EPLs) – with LED light sources (for EPL Gc or Dc only). NOTE 2 Continuous divergent LED light sources for other than EPL Gc or Dc are not excluded from the standard due to the uncertainty of potential ignition concerns regarding high irradiance. 3) Optical radiation sources for EPL Mb, Gb or Gc and Db or Dc applications which comply with Class 1 limits in accordance with IEC 60825-1. NOTE 3 The referenced Class 1 limits are those that involve emission limits below 15 mW measured at a distance from the optical radiation source in accordance with IEC 60825-1, with this measured distance reflected in the Ex application. 4) Single or multiple optical fibre cables not part of optical fibre equipment if the cables: – comply with the relevant industrial standards, along with additional protective means, e.g. robust cabling, conduit or raceway (for EPL Gb, Db, Mb, Gc or Dc) – comply with the relevant industrial standards (for EPL Gc or Dc). 5) Enclosed equipment involving an enclosure that fully contains the optical radiation and that complies with a suitable type of protection as required by the involved EPL, with the enclosure complying with one of the following conditions: – An enclosure for which an ignition due to optical radiation in combination with absorbers inside the enclosure would be acceptable such as flameproof \"d\" enclosures (IEC 60079-1), or – An enclosure for which protection regarding ingress of an explosive gas atmosphere is provided, such as pressurized \"p\" enclosures (IEC 60079-2), restricted breathing \"nR\" enclosure (IEC 60079-15), or – An enclosure for which protection regarding ingress of an explosive dust atmosphere is provided, such as dust protection \"t\" enclosures\" (IEC 60079-31), or – An enclosure for which protection regarding ingress of absorbers is provided (such as IP 6X enclosures) and where no internal absorbers are to be expected. NOTE 4 For these scope exclusions based on enclosure constructions, it is anticipated that the enclosures are not opened in the explosive atmosphere, so that ingress is protected. -------------------------------------------------------------------------------------------------------------------------------- Préface CSA Ce document constitue la première édition de la CAN/CSA-C22.2 nº 60079-28, Atmosphères explosives — Partie 28 : Protection du matériel et des systèmes de transmission utilisant le rayonnement optique . Il s’agit de l’adoption, avec exigences propres au Canada, de la norme IEC (Commission Électrotechnique Internationale) 60079-28 (deuxième édition, 2015-05) qui porte le même titre. Il fait partie d’une série de normes publiées par le Groupe CSA qui constituent le Code canadien de l’électricité, Deuxième partie. Par souci de brièveté, tout au long de ce document, il sera appelé «CAN/CSA-C22.2 nº 60079-28». Cette norme est conçue pour être utilisée de concert avec la CAN/CSA-C22.2 nº 60079-0, Atmosphères explosives — Partie 0 : Matériel — Exigences générales. Cette norme a été élaborée conformément aux exigences du Conseil canadien des normes concernant les Normes nationales du Canada. Cette norme a été publiée en tant que Norme nationale du Canada par Groupe CSA. Domaine d\'application La présente partie de l\'IEC 60079 spécifie les exigences, les essais et le marquage du matériel émettant des rayonnements optiques destiné à être utilisé dans des atmosphères explosives. Elle couvre également le matériel situé à l\'extérieur de l\'atmosphère explosive ou protégé par un mode de protection indiqué dans l\'IEC 60079-0, mais qui génère des rayonnements optiques qui sont destinés à pénétrer dans une atmosphère explosive. Elle couvre les Groupes I, II et III, et les EPL Ga, Gb, Gc, Da, Db, Dc, Ma et Mb. La présente norme contient des exigences pour le rayonnement optique dans l’étendue de longueur d’onde de 380 nm à 10 μm .Elle couvre les mécanismes d’inflammation suivants: • Le rayonnement optique est absorbé par les surfaces ou particules, provoquant leur échauffement et, dans certaines circonstances, celles-ci peuvent atteindre une température qui amorce l’inflammation de l’atmosphère explosive environnante. • Dans certains cas rares particuliers, le craquage direct d’un gaz par laser, au point de focalisation d’un faisceau puissant, produisant un plasma et une onde de choc, les deux agissant en définitive comme source d’inflammation. Ces processus peuvent prendre naissance dans un matériau solide proche de son point de craquage. NOTE 1 Voir les points a) et b) de l’introduction. La présente norme ne couvre pas l’inflammation par rayonnement ultraviolet et par absorption du rayonnement dans le mélange explosif lui-même. Les absorbeurs explosifs ou absorbeurs qui contiennent leur propre oxydant/comburant de même que les absorbeurs catalytiques sont également hors du domaine d\'application de la présente norme. La présente norme spécifie les exigences pour les matériels destinés à l’utilisation dans des conditions atmosphériques. La présente norme complète et modifie les exigences générales de l\'IEC 60079-0. Lorsqu’une exigence de la présente norme entre en conflit avec une exigence de l\'IEC 60079-0, l’exigence de la présente norme prévaut. La présente norme s\'applique au matériel à fibre optique et au matériel optique, y compris les LED et les matériels à laser, à l\'exception des matériels décrits ci-dessous: 1) Les LED non divergentes utilisées par exemple pour afficher le statut d\'un matériel ou pour une fonction de rétroéclairage. 2) Tous les luminaires (fixes, portables ou transportables), les lampes à main et les lampeschapeaux; destinés à être alimentés par le réseau (avec ou sans isolation galvanique) ou par des batteries: – avec des sources lumineuses divergentes continues (pour tous les EPL) – avec des sources lumineuses LED (pour les EPL Gc ou Dc uniquement). NOTE 2 Les sources lumineuses LED divergentes continues autres que pour les EPL Gc ou Dc ne sont pas exclues de la norme en raison de l’incertitude liée à la probabilité d’inflammation associée à l’éclairement élevé. 3) Les sources de rayonnement optique pour les applications EPL Mb, Gb ou Gc et Db ou Dc qui satisfont aux limites de Classe 1 conformément à l\'IEC 60825-1. NOTE 3 Les limites de Classe 1 référencées sont celles qui impliquent des limites d\'émissions inférieures à 15 mW mesurées à une certaine distance de la source de rayonnement optique conformément à l’IEC 60825-1, cette distance mesurée étant reflétée dans l’application Ex. 4) Les câbles à fibres optiques simples ou multiples ne faisant pas partie du matériel à fibre optique si les câbles: – satisfont aux normes industrielles pertinentes, ainsi que les moyens de protection supplémentaires, comme les câblages robustes, les conduits ou les chemins (pour EPL Gb, Db, Mb, Gc ou Dc) – satisfont aux normes industrielles pertinentes (pour EPL Gc ou Dc). 5) Les matériels sous enveloppe impliquant une enveloppe qui confine totalement les rayonnements optiques et qui satisfait à un mode de protection adapté tel que requis par l\'EPL concerné, l\'enveloppe satisfaisant à l\'une des conditions suivantes: – Une enveloppe pour laquelle une inflammation due aux rayonnements optiques en combinaison avec des absorbeurs à l\'intérieur de l\'enveloppe est acceptable (par exemple, les enveloppes \"d\" antidéflagrantes) (IEC 60079-1), ou – Une enveloppe pour laquelle la protection relative à la pénétration d\'une atmosphère explosive gazeuse est prévue, comme les enveloppes sous pression \"p\" (IEC 60079-2), l\'enveloppe \"nR\" à respiration réduite (IEC 60079-15), ou – Une enveloppe pour laquelle la protection relative à la pénétration d\'une atmosphère explosive poussiéreuse est prévue comme les enveloppes \"t\" antipoussière (IEC 60079-31), ou – Une enveloppe pour laquelle la protection relative à la pénétration d\'absorbeurs est prévue (comme les enveloppes IP 6X) et où aucun absorbeur interne n\'est prévu. NOTE 4 Pour ces exclusions du domaine d\'application fondées sur la construction des enveloppes, on prévoit que les enveloppes ne sont pas ouvertes dans l\'atmosphère explosive, de sorte que l\'entrée est protégée.

    Scope - (Show below) - (Hide below)

    CSA Preface This is the first edition of CAN/CSA-C22.2 No. 60079-28, Explosive atmospheres — Part 28: Protection of equipment and transmission systems using optical radiation, which is an adoption, with Canadian deviations, of the identically titled IEC (International Electrotechnical Commission) Standard 60079-28 (second edition, 2015-05). It is one in a series of Standards issued by CSA Group under Part II of the Canadian Electrical Code. For brevity, this Standard will be referred to as \"CAN/CSA-C22.2 No. 60079-28\" throughout. This Standard is intended to be used in conjunction with CAN/CSA-C22.2 No. 60079-0, Explosive atmospheres — Part 0: Equipment — General requirements. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope This part of IEC 60079 specifies the requirements, testing and marking of equipment emitting optical radiation intended for use in explosive atmospheres. It also covers equipment located outside the explosive atmosphere or protected by a Type of Protection listed in IEC 60079-0, but which generates optical radiation that is intended to enter an explosive atmosphere. It covers Groups I, II and III, and EPLs Ga, Gb, Gc, Da, Db, Dc, Ma and Mb. This standard contains requirements for optical radiation in the wavelength range from 380 nm to 10 μm. It covers the following ignition mechanisms: • Optical radiation is absorbed by surfaces or particles, causing them to heat up, and under certain circumstances this may allow them to attain a temperature which will ignite a surrounding explosive atmosphere. • In rare special cases, direct laser induced breakdown of the gas at the focus of a strong beam, producing plasma and a shock wave both eventually acting as ignition source. These processes can be supported by a solid material close to the breakdown point. NOTE 1 See a) and d) of the introduction. This standard does not cover ignition by ultraviolet radiation and by absorption of the radiation in the explosive mixture itself. Explosive absorbers or absorbers that contain their own oxidizer as well as catalytic absorbers are also outside the scope of this standard. This standard specifies requirements for equipment intended for use under atmospheric conditions. This standard supplements and modifies the general requirements of IEC 60079-0. Where a requirement of this standard conflicts with a requirement of IEC 60079-0, the requirement of this standard takes precedence. This standard applies to optical fibre equipment and optical equipment, including LED and laser equipment, with the exception of the equipment detailed below: 1) Non-array divergent LEDs used for example to show equipment status or backlight function. 2) All luminaires (fixed, portable or transportable), hand lights and caplights; intended to be supplied by mains (with or without galvanic isolation) or powered by batteries: – with continuous divergent light sources (for all EPLs) – with LED light sources (for EPL Gc or Dc only). NOTE 2 Continuous divergent LED light sources for other than EPL Gc or Dc are not excluded from the standard due to the uncertainty of potential ignition concerns regarding high irradiance. 3) Optical radiation sources for EPL Mb, Gb or Gc and Db or Dc applications which comply with Class 1 limits in accordance with IEC 60825-1. NOTE 3 The referenced Class 1 limits are those that involve emission limits below 15 mW measured at a distance from the optical radiation source in accordance with IEC 60825-1, with this measured distance reflected in the Ex application. 4) Single or multiple optical fibre cables not part of optical fibre equipment if the cables: – comply with the relevant industrial standards, along with additional protective means, e.g. robust cabling, conduit or raceway (for EPL Gb, Db, Mb, Gc or Dc) – comply with the relevant industrial standards (for EPL Gc or Dc). 5) Enclosed equipment involving an enclosure that fully contains the optical radiation and that complies with a suitable type of protection as required by the involved EPL, with the enclosure complying with one of the following conditions: – An enclosure for which an ignition due to optical radiation in combination with absorbers inside the enclosure would be acceptable such as flameproof \"d\" enclosures (IEC 60079-1), or – An enclosure for which protection regarding ingress of an explosive gas atmosphere is provided, such as pressurized \"p\" enclosures (IEC 60079-2), restricted breathing \"nR\" enclosure (IEC 60079-15), or – An enclosure for which protection regarding ingress of an explosive dust atmosphere is provided, such as dust protection \"t\" enclosures\" (IEC 60079-31), or – An enclosure for which protection regarding ingress of absorbers is provided (such as IP 6X enclosures) and where no internal absorbers are to be expected. NOTE 4 For these scope exclusions based on enclosure constructions, it is anticipated that the enclosures are not opened in the explosive atmosphere, so that ingress is protected. -------------------------------------------------------------------------------------------------------------------------------- Préface CSA Ce document constitue la première édition de la CAN/CSA-C22.2 nº 60079-28, Atmosphères explosives — Partie 28 : Protection du matériel et des systèmes de transmission utilisant le rayonnement optique . Il s’agit de l’adoption, avec exigences propres au Canada, de la norme IEC (Commission Électrotechnique Internationale) 60079-28 (deuxième édition, 2015-05) qui porte le même titre. Il fait partie d’une série de normes publiées par le Groupe CSA qui constituent le Code canadien de l’électricité, Deuxième partie. Par souci de brièveté, tout au long de ce document, il sera appelé «CAN/CSA-C22.2 nº 60079-28». Cette norme est conçue pour être utilisée de concert avec la CAN/CSA-C22.2 nº 60079-0, Atmosphères explosives — Partie 0 : Matériel — Exigences générales. Cette norme a été élaborée conformément aux exigences du Conseil canadien des normes concernant les Normes nationales du Canada. Cette norme a été publiée en tant que Norme nationale du Canada par Groupe CSA. Domaine d\'application La présente partie de l\'IEC 60079 spécifie les exigences, les essais et le marquage du matériel émettant des rayonnements optiques destiné à être utilisé dans des atmosphères explosives. Elle couvre également le matériel situé à l\'extérieur de l\'atmosphère explosive ou protégé par un mode de protection indiqué dans l\'IEC 60079-0, mais qui génère des rayonnements optiques qui sont destinés à pénétrer dans une atmosphère explosive. Elle couvre les Groupes I, II et III, et les EPL Ga, Gb, Gc, Da, Db, Dc, Ma et Mb. La présente norme contient des exigences pour le rayonnement optique dans l’étendue de longueur d’onde de 380 nm à 10 μm .Elle couvre les mécanismes d’inflammation suivants: • Le rayonnement optique est absorbé par les surfaces ou particules, provoquant leur échauffement et, dans certaines circonstances, celles-ci peuvent atteindre une température qui amorce l’inflammation de l’atmosphère explosive environnante. • Dans certains cas rares particuliers, le craquage direct d’un gaz par laser, au point de focalisation d’un faisceau puissant, produisant un plasma et une onde de choc, les deux agissant en définitive comme source d’inflammation. Ces processus peuvent prendre naissance dans un matériau solide proche de son point de craquage. NOTE 1 Voir les points a) et b) de l’introduction. La présente norme ne couvre pas l’inflammation par rayonnement ultraviolet et par absorption du rayonnement dans le mélange explosif lui-même. Les absorbeurs explosifs ou absorbeurs qui contiennent leur propre oxydant/comburant de même que les absorbeurs catalytiques sont également hors du domaine d\'application de la présente norme. La présente norme spécifie les exigences pour les matériels destinés à l’utilisation dans des conditions atmosphériques. La présente norme complète et modifie les exigences générales de l\'IEC 60079-0. Lorsqu’une exigence de la présente norme entre en conflit avec une exigence de l\'IEC 60079-0, l’exigence de la présente norme prévaut. La présente norme s\'applique au matériel à fibre optique et au matériel optique, y compris les LED et les matériels à laser, à l\'exception des matériels décrits ci-dessous: 1) Les LED non divergentes utilisées par exemple pour afficher le statut d\'un matériel ou pour une fonction de rétroéclairage. 2) Tous les luminaires (fixes, portables ou transportables), les lampes à main et les lampeschapeaux; destinés à être alimentés par le réseau (avec ou sans isolation galvanique) ou par des batteries: – avec des sources lumineuses divergentes continues (pour tous les EPL) – avec des sources lumineuses LED (pour les EPL Gc ou Dc uniquement). NOTE 2 Les sources lumineuses LED divergentes continues autres que pour les EPL Gc ou Dc ne sont pas exclues de la norme en raison de l’incertitude liée à la probabilité d’inflammation associée à l’éclairement élevé. 3) Les sources de rayonnement optique pour les applications EPL Mb, Gb ou Gc et Db ou Dc qui satisfont aux limites de Classe 1 conformément à l\'IEC 60825-1. NOTE 3 Les limites de Classe 1 référencées sont celles qui impliquent des limites d\'émissions inférieures à 15 mW mesurées à une certaine distance de la source de rayonnement optique conformément à l’IEC 60825-1, cette distance mesurée étant reflétée dans l’application Ex. 4) Les câbles à fibres optiques simples ou multiples ne faisant pas partie du matériel à fibre optique si les câbles: – satisfont aux normes industrielles pertinentes, ainsi que les moyens de protection supplémentaires, comme les câblages robustes, les conduits ou les chemins (pour EPL Gb, Db, Mb, Gc ou Dc) – satisfont aux normes industrielles pertinentes (pour EPL Gc ou Dc). 5) Les matériels sous enveloppe impliquant une enveloppe qui confine totalement les rayonnements optiques et qui satisfait à un mode de protection adapté tel que requis par l\'EPL concerné, l\'enveloppe satisfaisant à l\'une des conditions suivantes: – Une enveloppe pour laquelle une inflammation due aux rayonnements optiques en combinaison avec des absorbeurs à l\'intérieur de l\'enveloppe est acceptable (par exemple, les enveloppes \"d\" antidéflagrantes) (IEC 60079-1), ou – Une enveloppe pour laquelle la protection relative à la pénétration d\'une atmosphère explosive gazeuse est prévue, comme les enveloppes sous pression \"p\" (IEC 60079-2), l\'enveloppe \"nR\" à respiration réduite (IEC 60079-15), ou – Une enveloppe pour laquelle la protection relative à la pénétration d\'une atmosphère explosive poussiéreuse est prévue comme les enveloppes \"t\" antipoussière (IEC 60079-31), ou – Une enveloppe pour laquelle la protection relative à la pénétration d\'absorbeurs est prévue (comme les enveloppes IP 6X) et où aucun absorbeur interne n\'est prévu. NOTE 4 Pour ces exclusions du domaine d\'application fondées sur la construction des enveloppes, on prévoit que les enveloppes ne sont pas ouvertes dans l\'atmosphère explosive, de sorte que l\'entrée est protégée.

    General Product Information - (Show below) - (Hide below)

    Document Type Standard
    Product Note THIS STANDARD ALSO REFERS TO CAN/CSA-C22.2 nº 60079-0 , CAN/CSA-C22.2 nº 60079-0 ,CAN/CSA-C22.2 nº 60079-11,CAN/CSA-C22.2 nº 60079-11, IEC 61508, IEC 61511
    Publisher Canadian Standards Association
    Status Current
    Supersedes
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective