• CAN/CSA-C22.2 NO. 60947-7-3:17

    Current The latest, up-to-date edition.

    Low-voltage switchgear and controlgear ? Part 7-3: Ancillary equipment ? Safety requirements for fuse terminal blocks (Trinational standard NMX-J-538/7-3-ANCE with UL 60947-7-3)

    Available format(s):  Hardcopy, PDF

    Language(s):  French, English

    Published date:  01-01-2017

    Publisher:  Canadian Standards Association

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    Preface
    NATIONAL DIFFERENCES
    FOREWORD
    INTRODUCTION
    1 General
    2 Definitions
    3 Classification
    4 Characteristics
    5 Product information
    6 Normal service, mounting and transport conditions
    7 Constructional and performance requirements
    8 Tests
    Annex A (normative) - Gauges
    Annex B (informative) - Power dissipation values P[V]
            and P[VK]
    Annex C (normative) - Order of tests and number of
            specimens
    Annex DVA (normative) - IEC, Canadian, Mexican, and
              United States Standard References
    Annex DVB (normative)
    Bibliography

    Abstract - (Show below) - (Hide below)

    Pertains to fuse terminal blocks with screw-type or screwless-type clamping units for the connection of rigid (solid or stranded) or flexible copper conductors for the reception of cartridge fuse-links in accordance with IEC 60127-2, intended primarily for industrial or similar use in circuits not exceeding 1000 V a.c., up to 1000 Hz or 1500 V d.c., and having a maximum short-circuit breaking capacity of 1500 A.

    Scope - (Show below) - (Hide below)

    Preface This is the harmonized ANCE, CSA Group, and UL standard for Low-Voltage Switchgear and Controlgear - Part 7-3: Ancillary Equipment - Safety Requirements for Fuse Terminal Blocks. It is the first edition of NMX-J-538/7-3-ANCE, the first edition of CAN/CSA-C22.2 No. 60947-7-3, and the third edition of UL 60947-7-3. This edition of UL 60947-7-3 supersedes the previous edition (s) published on May 6, 2011.? This harmonized standard is based on IEC Publication 60947-7-3: Edition 1 (2002), Low-Voltage Switchgear and Controlgear - Part 7-3: Ancillary Equipment - Safety Requirements for Fuse Terminal Blocks, as revised by corrigendum (March 2003). IEC 60947-7-3 is copyrighted by the IEC.? Scope This part of IEC 60947 applies to fuse terminal blocks with screw-type or screwless-type clamping units for the connection of rigid (solid or stranded) or flexible copper conductors for the reception of cartridge fuse-links in accordance with IEC 60127-2, intended primarily for industrial or similar use in circuits not exceeding 1 000 V a.c., up to 1 000 Hz or 1 500 V d.c., and having a maximum short-circuit breaking capacity of 1 500 A.? They are intended for installation in electrical equipment with enclosures which surround the fuse terminal blocks to such an extent that they are accessible only with the aid of a tool.? For certain applications, for example in control circuits, the fuse terminal blocks may be designed exclusively for short-circuit protection.? NOTE This Standard may be used as a guide for fuse terminal blocks for the reception of special cartridge fuselinks which do not meet the requirements of IEC 60127-2.? The object of this standard is to specify safety requirements and test methods for the mechanical, electrical and thermal characteristics of fuse terminal\'s blocks, to ensure the compatibility between terminal blocks and standardized fuse-links.? This Standard may be used as a guide for? fuse terminal blocks requiring the fixing of special devices to the conductors, for example quick connect terminations or wrapped connections, etc.;? fuse terminal blocks providing direct contact to the conductors by means of edges or points penetrating the insulation, for example insulation displacement connections, etc.? Where applicable in this standard, the term \"clamping unit\" has been used instead of the term \"terminal\". This is taken into account in case of reference to IEC 60947-1.? 1.1DV D2 Modification by adding the following:? This Standard specifies requirements for fuse terminal blocks with screw-type or screwless-type clamping units for the connection of rigid (solid or stranded) or flexible copper conductors for the reception of cartridge fuse-links, in accordance with Annex DVB, National Electrical Code, NFPA 70 (for use in the USA), CSA C22.1-15 Canadian Electrical Code, Part I (for use in Canada), and NOM-001-SEDE, Electrical Installations (Utility) [for use in Mexico].

    General Product Information - (Show below) - (Hide below)

    Development Note Also numbered as NMX-J-538/7-3-ANCE with UL 60947-7-3. (02/2017)
    Document Type Standard
    Publisher Canadian Standards Association
    Status Current

    Standards Referencing This Book - (Show below) - (Hide below)

    IEC 60364-4-43:2008 Low-voltage electrical installations - Part 4-43: Protection for safety - Protection against overcurrent
    IEC 60127-6:2014 Miniature fuses - Part 6: Fuse-holders for miniature fuse-links
    C22.1-15 Canadian Electrical Code, Part I (23rd Edition), Safety Standard for Electrical Installations
    CAN/CSA-C22.2 NO. 60947-7-1:17 Low-voltage switchgear and controlgear ? Part 7-1: Ancillary equipment ? Terminal blocks for copper conductors (Trinational standard with NMX-J-538/7-1-ANCE and UL 60947-7-1)
    ISO 3:1973 Preferred numbers Series of preferred numbers
    IEC 60947-7-1:2009 Low-voltage switchgear and controlgear - Part 7-1: Ancillary equipment - Terminal blocks for copper conductors
    IEC 60127-1:2006+AMD1:2011+AMD2:2015 CSV Miniature fuses - Part 1: Definitions for miniature fuses andgeneral requirements for miniature fuse-links
    IEC 60127-2:2014 Miniature fuses - Part 2: Cartridge fuse-links
    IEC 60715:2017 Dimensions of low-voltage switchgear and controlgear - Standardized mounting on rails for mechanical support of switchgear, controlgear and accessories
    IEC 61180-2:1994 High-voltage test techniques for low-voltage equipment - Part 2: Test equipment
    CAN/CSA-C22.2 NO. 60947-1-13 (R2018) Low-voltage switchgear and controlgear - Part 1: General rules (Tri-national standard, with UL 60947-1 and NMX-J-515-ANCE)
    IEC 60947-1:2007+AMD1:2010+AMD2:2014 CSV Low-voltage switchgear and controlgear - Part 1: General rules
    NFPA 70 : 2017 NATIONAL ELECTRICAL CODE
    UL 60947-7-1:4ED 2017-01 Low-voltage switchgear and controlgear - Part 7-1: Ancillary equipment - Terminal blocks for copper conductors
    ISO 4046:1978 Paper, board, pulp and related terms — Vocabulary
    UL 248-1 : 3 LOW-VOLTAGE FUSES - PART 1: GENERAL REQUIREMENTS
    IEC 61180-1:1992 High-voltage test techniques for low voltage equipment - Part 1: Definitions, test and procedure requirements
    IEC 60216-1:2013 Electrical insulating materials - Thermal endurance properties - Part 1: Ageing procedures and evaluation of test results
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective