• CSA C390 : 2010 : INC : UPD 1 : 2015 : R201500

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    TEST METHODS, MARKING REQUIREMENTS, AND ENERGY EFFICIENCY LEVELS FOR THREE-PHASE INDUCTION MOTORS

    Available format(s):  Hardcopy, PDF

    Superseded date:  25-09-2020

    Language(s):  English

    Published date:  01-01-2015

    Publisher:  Canadian Standards Association

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    Preface
    1 Scope
    2 Reference publications
    3 Definitions and symbols
    4 General
    5 General test requirements - Measurements
    6 Efficiency requirements
    7 Test method
    8 Marking
    9 Determining nominal efficiency
    Annexes
    A (informative) - Guidelines for determining energy
      efficiency and information to be recorded
    B (informative) - Linear regression analysis
    C (informative) - Procedure for correction of dynamometer
      torque readings
    D (informative) - Guideline for compliance with Canadian
      (federal and provincial) energy efficiency regulations
      for electric motors
    E (informative) - Harmonic Voltage Factor (HVF)
    F (informative) - Bibliography

    Abstract - (Show below) - (Hide below)

    Describes the test methods and marking requirements, and references energy efficiency levels for three-phase induction motors.

    General Product Information - (Show below) - (Hide below)

    Development Note Supersedes CSA C390.1-C390.2. (04/2010)
    Document Type Standard
    Product Note Reconfirmed EN
    Publisher Canadian Standards Association
    Status Superseded
    Superseded By
    Supersedes

    Standards Referencing This Book - (Show below) - (Hide below)

    NEMA MG 1 : 2016 MOTORS AND GENERATORS
    CSA C22.2 No. 77 : 2014 MOTORS WITH INHERENT OVERHEATING PROTECTION
    IEC 60034-2-1:2014 Rotating electrical machines - Part 2-1: Standard methods for determining losses and efficiency from tests (excluding machines for traction vehicles)
    CSA C22.2 No. 100 : 2014 MOTORS AND GENERATORS
    IEEE 112-2004 IEEE Standard Test Procedure for Polyphase Induction Motors and Generators
    IEC 60034-30:2008 Rotating electrical machines - Part 30: Efficiency classes of single-speed, three-phase, cage-induction motors (IE-code)