• CSA CEI/IEC 1288.2 : 1998

    Withdrawn A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

    CARDIAC DEFIBRILLATORS - CARDIAC DEFIBRILLATORS-MONITORS - PART 2: MAINTENANCE

    Available format(s):  Hardcopy, PDF

    Withdrawn date:  28-11-2016

    Language(s):  English - French, French

    Published date:  31-12-2011

    Publisher:  Canadian Standards Association

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    Foreword
    Clause
    1 Scope
    2 Reference documents
    3 Definitions
       3.1 Applied part
       3.2 Cardiac defibrillator
       3.3 Cardiac defibrillator-monitor
       3.4 Cardiac monitor
       3.5 Defibrillator electrodes
       3.6 Delivered energy
       3.7 Internal discharge circuit
       3.8 Stand-by
       3.9 Synchronizer
    4 Preventive maintenance
       4.1 General
       4.2 Intervals of maintenance and testing
       4.3 Maintenance performed by the operator
           (First level)
       4.4 Maintenance performed by the clinical engineering
           personnel (Second level)
       4.5 Measuring instruments
       4.6 Checking the class and type of equipment
    5 Measurements done by the clinical engineering
       personnel
       5.1 General
       5.2 Checking the protective earth conductor
       5.3 Checking leakage currents
       5.4 Checking accuracy of delivered energy
       5.5 Insulation test of the high voltage parts
       5.6 Checking energy loose rate
       5.7 Checking synchronizer performance
       5.8 Checking the battery capacity
       5.9 Final check
    Figures
    Annexes
    A Leakage current measuring set-up
    B Example of a measuring device and its frequency
       characteristics
    C Measuring device

    Abstract - (Show below) - (Hide below)

    Gives guidelines for cardiac defibrillator maintenance by clinical engineering personnel. (Automatic external and automatic implantable defibrillators are not covered).

    General Product Information - (Show below) - (Hide below)

    Document Type Standard
    Publisher Canadian Standards Association
    Status Withdrawn
    Supersedes

    Standards Referenced By This Book - (Show below) - (Hide below)

    CSA Z32 : 2015 ELECTRICAL SAFETY AND ESSENTIAL ELECTRICAL SYSTEMS IN HEALTH CARE FACILITIES

    Standards Referencing This Book - (Show below) - (Hide below)

    IEC 60601-1:2005+AMD1:2012 CSV Medical electrical equipment - Part 1: General requirements for basic safety and essential performance
    IEC 60601-2-4:2010 Medical electrical equipment - Part 2-4: Particular requirements for the basic safety and essential performance of cardiac defibrillators
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective