• There are no items in your cart

CSA E60598.1 : 2016

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

LUMINAIRES - PART 1: GENERAL REQUIREMENTS AND TESTS

Available format(s)

Hardcopy , PDF

Superseded date

17-07-2021

Language(s)

English

Published date

01-01-2016

FOREWORD
SECTION 0: GENERAL INTRODUCTION
SECTION 1: TERMS AND DEFINITIONS
SECTION 2: CLASSIFICATION OF LUMINAIRES
SECTION 3: MARKING
SECTION 4: CONSTRUCTION
SECTION 5: EXTERNAL AND INTERNAL WIRING
SECTION 6: Not used
SECTION 7: PROVISION FOR EARTHING
SECTION 8: PROTECTION AGAINST ELECTRIC SHOCK
SECTION 9: RESISTANCE TO DUST, SOLID OBJECTS AND MOISTURE
SECTION 10: INSULATION RESISTANCE AND ELECTRIC STRENGTH,
            TOUCH CURRENT AND PROTECTIVE CONDUCTOR CURRENT
SECTION 11: CREEPAGE DISTANCES AND CLEARANCES
SECTION 12: ENDURANCE TEST AND THERMAL TEST
SECTION 13: RESISTANCE TO HEAT, FIRE AND TRACKING
SECTION 14: SCREW TERMINALS
SECTION 15: SCREWLESS TERMINALS AND ELECTRICAL CONNECTIONS
Annex A (normative) - Test to establish whether a conductive
        part may cause an electric shock
Annex B (normative) - Test lamps
Annex C (normative) - Abnormal circuit conditions
Annex D (normative) - Draught-proof enclosure
Annex E (normative) - Determination of winding temperature
        rises by the increase-inresistance method
Annex F (normative) - Test for resistance to stress corrosion
        of copper and copper alloys
Annex G (normative) - Measurement of touch current and
        protective conductor current
Annex H (Void)
Annex I (Void)
Annex J (informative) - Explanation of IP numbers for degrees
        of protection
Annex K (informative) - Temperature measurement
Annex L (informative) - Guide to good practice in luminaire
        design
Annex M (normative) - Determination of creepage distances
        and clearances
Annex N (informative) - Explanation of marking for luminaires
        that are not suitable for mounting on normally flammable
        surfaces and covering with insulation materials
Annex O (Void)
Annex P (normative) - Absorption requirements for the
        protective shield to be fitted to luminaires designed
        for metal halide lamps which emit a high level of UV
        radiation
Annex Q (informative) - Conformity testing during manufacture
Annex R (normative) - Schedule of amended subclauses
        containing more serious/critical requirements which
        require products to be retested
Annex S (normative) - Requirements for the identification of
        a family or range of luminaires for type testing
Annex T (informative) - Reference to Class 0
Annex U (informative) - Creepage and clearances distances
        for luminaires where a higher degree of availability
        (impulse withstand category III) may be requested
Annex V (normative) - Additional test requirements for
        terminal blocks with integrated screwless earthing
        contact for direct connection to the luminaire housing
        or to parts of the body
Annex W (normative) - Alternative thermal test for
        thermoplastic luminaires
Annex X (normative)
Annex XA (normative) - Additional marking requirements
Bibliography

This Part 1 of IEC 60598 specifies general requirements for luminaires, incorporating electric light sources for operation from supply voltages up to 1 000 V.

DevelopmentNote
Supersedes CSA E598.1 (10/2004)
DocumentType
Standard
ISBN
978-1-4883-0337-1
Pages
480
PublisherName
Canadian Standards Association
Status
Superseded

IEC 60950-1:2005+AMD1:2009+AMD2:2013 CSV Information technology equipment - Safety - Part 1: General requirements
IEC 60112:2003+AMD1:2009 CSV Method for the determination of the proof and the comparative tracking indices of solid insulating materials
IEC 60811-3-1:1985 Common test methods for insulating and sheathing materials ofelectric cables - Part 3: Methods specific to PVC compounds -Section One: Pressure test at high temperature - Tests forresistance to cracking
IEC 60432-1:1999+AMD1:2005+AMD2:2011 CSV Incandescent lamps - Safety specifications - Part 1: Tungsten filament lamps for domestic and similar general lighting purposes
IEC 60238:2016+AMD1:2017 CSV Edison screw lampholders
IEC TR 62778:2014 Application of IEC 62471 for the assessment of blue light hazard to light sources and luminaires
IEC 60384-14:2013+AMD1:2016 CSV Fixed capacitors for use in electronic equipment - Part 14: Sectional specification - Fixed capacitors for electromagnetic interference suppression and connection to the supply mains
IEC 60662:2011 High-pressure sodium vapour lamps - Performance specifications
IEC 60682:1980 Standard method of measuring the pinch temperature of quartz-tungsten-halogen lamps
IEC 60050-195:1998 International Electrotechnical Vocabulary (IEV) - Part 195: Earthing and protection against electric shock
IEC 60634:1993 Heat test source (H.T.S.) lamps for carrying out heating tests on luminaires
IEC 60364-4-41:2005+AMD1:2017 CSV Low voltage electrical installations - Part 4-41: Protection for safety - Protection against electric shock
IEC 61347-2-9:2012 Lamp controlgear - Part 2-9: Particular requirements for electromagnetic controlgear for discharge lamps (excluding fluorescent lamps)
CSA C22.2 No. 0.4 : 2004(R2013) BONDING OF ELECTRICAL EQUIPMENT
IEC TR 60083:2015 Plugs and socket-outlets for domestic and similar general use standardized in member countries of IEC
IEC TR 62471-2:2009 Photobiological safety of lamps and lamp systems - Part 2: Guidance on manufacturing requirements relating to non-laser optical radiation safety
IEC 60364-5-51:2005 Electrical installations of buildings - Part 5-51: Selection and erection of electrical equipment - Common rules
IEC 61210:2010 Connecting devices - Flat quick-connect terminations for electrical copper conductors - Safety requirements
IEC 61347-1:2015 RLV Lamp controlgear - Part 1: General and safety requirements
IEC 60695-2-11:2014 Fire hazard testing - Part 2-11: Glowing/hot-wire based test methods - Glow-wire flammability test method for end-products (GWEPT)
IEC 60570:2003+AMD1:2017 CSV Electrical supply track systems for luminaires
IEC 60929:2011+AMD1:2015 CSV AC and/or DC-supplied electronic control gear for tubularfluorescent lamps - Performance requirements
IEC 60598-2-5:2015 Luminaires - Part 2-5: Particular requirements - Floodlights
IEC 60400:2017 Lampholders for tubular fluorescent lamps and starterholders
IEC 61558-2-6:2009 Safety of transformers, reactors, power supply units and similar products for supply voltages up to 1 100 V - Part 2-6: Particular requirements and tests for safety isolating transformers and power supply units incorporating safety isolating transformers
IEC 60598-2-6:1994 Luminaires - Part 2: Particular requirements - Section 6: Luminaires with built-in transformers for filament lamps
C22.2 NO. 43-17 Lampholders (Binational standard with UL 496)
ISO 75-2:2013 Plastics — Determination of temperature of deflection under load — Part 2: Plastics and ebonite
IEC 60085:2007 Electrical insulation - Thermal evaluation and designation
IEC 61199:2011+AMD1:2012+AMD2:2014 CSV Single-capped fluorescent lamps - Safety specifications
IEC 61167:2015 Metal halide lamps - Performance specification
IEC 60925:1989+AMD1:1996+AMD2:2001 CSV DC supplied electronic ballasts for tubular fluorescent lamps - Performance requirements
IEC 61346-1:1996 Industrial systems, installations and equipment and industrial products - Structuring principles and reference designations - Part 1: Basic rules
IEC 60364-7-702:2010 Low-voltage electrical installations - Part 7-702: Requirements for special installations or locations - Swimming pools and fountains
IEC 60921:2004+AMD1:2006 CSV Ballasts for tubular fluorescent lamps - Performance requirements
IEC 61558-1:2017 Safety of transformers, reactors, power supply units and combinations thereof - Part 1: General requirements and tests
IEC 60598-2-3:2002+AMD1:2011 CSV Luminaires - Part 2-3: Particular requirements - Luminaires for road and street lighting
IEC 60901:1996+AMD1:1997+AMD2:2000 CSV Single-capped fluorescent lamps - Performance specifications
IEC 60364-7-701:2006 Low-voltage electrical installations - Part 7-701: Requirements for special installations or locations - Locations containing a bath or shower
IEC 62035:2014+AMD1:2016 CSV Discharge lamps (excluding fluorescent lamps) - Safety specifications
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV Degrees of protection provided by enclosures (IP Code)
IEC 61058-1:2016 Switches for appliances - Part 1: General requirements
IEC 60364-4-44:2007+AMD1:2015 CSV Low-voltage electrical installations - Part 4-44: Protection for safety - Protection against voltage disturbances and electromagnetic disturbances
CSA C22.2 No. 0.15 : 2015 ADHESIVE LABELS
IEC 60989:1991 Separating transformers, autotransformers, variable transformersand reactors.
IEC 61643-11:2011 Low-voltage surge protective devices - Part 11: Surge protective devices connected to low-voltage power systems - Requirements and test methods
IEC 80416-1:2008 Basic principles for graphical symbols for use on equipment - Part 1: Creation of graphical symbols for registration
IEC 62471:2006 Photobiological safety of lamps and lamp systems
IEC 61535:2009+AMD1:2012 CSV Installation couplers intended for permanent connection in fixedinstallations
IEC 60068-2-75:2014 Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests
IEC 60664-3:2016 Insulation coordination for equipment within low-voltage systems - Part 3: Use of coating, potting or moulding for protection against pollution
IEC 61558-2-5:2010 Safety of transformers, reactors, power supply units and combinations thereof - Part 2-5: Particular requirements and test for transformer for shavers, power supply units for shavers and shaver supply units
IEC 60695-10-2:2014 Fire hazard testing - Part 10-2: Abnormal heat - Ball pressure test method
IEC TR 60972:1989 Classification and interpretation of new lighting products
IEC 60432-2:1999+AMD1:2005+AMD2:2012 CSV Incandescent lamps - Safety specifications - Part 2: Tungsten halogen lamps for domestic and similar general lighting purposes
ISO 4046-4:2002 Paper, board, pulps and related terms Vocabulary Part 4: Paper and board grades and converted products
AS 3771-1998 Road lighting luminaires with integral control gear
IEC 61140:2016 Protection against electric shock - Common aspects for installation and equipment
IEC 60155:1993 Glow-starters for fluorescent lamps
IEC 61032:1997 Protection of persons and equipment by enclosures - Probes for verification
IEC 60923:2005+AMD1:2006 CSV Auxiliaries for lamps - Ballasts for discharge lamps (excluding tubular fluorescent lamps) - Performance requirements
IEC 60432-3:2012 Incandescent lamps - Safety specifications - Part 3: Tungsten halogen lamps (non-vehicle)
IEC 60695-11-5:2016 Fire hazard testing - Part 11-5: Test flames - Needle-flame test method - Apparatus, confirmatory test arrangement and guidance
IEC 60068-2-14:2009 Environmental testing - Part 2-14: Tests - Test N: Change of temperature
IEC 60664-1:2007 Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests
CSA C22.2 No. 62031 : 2013(R2018) LED MODULES FOR GENERAL LIGHTING - SAFETY SPECIFICATIONS
IEC 60598-2-4:2017 Luminaires - Part 2-4: Particular requirements - Portable general purpose luminaires
IEC 61184:2017 Bayonet lampholders
IEC 60990:2016 Methods of measurement of touch current and protective conductor current
ISO 16893-1:2008 Wood-based panels Particleboard Part 1: Classifications
IEC 60360:1998 Standard method of measurement of lamp cap temperature rise
IEC 61195:1999+AMD1:2012+AMD2:2014 CSV Double-capped fluorescent lamps - Safety specifications
ISO 1891:2009 Fasteners — Terminology

€316.16
Excluding VAT

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.