• DIN EN 15193 E : 2008

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    ENERGY PERFORMANCE OF BUILDINGS - ENERGY REQUIREMENTS FOR LIGHTING

    Available format(s):  Hardcopy, PDF

    Superseded date:  01-10-2017

    Language(s):  English

    Published date:  01-01-2008

    Publisher:  German Institute for Standardisation (Deutsches Institut für Normung)

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    Foreword
    Introduction
    1 Scope
    2 Normative references
    3 Terms and definitions
    4 Calculating energy used for lighting
      4.1 Total energy used for lighting
          4.1.1 Total estimated energy
          4.1.2 Total annual energy used for lighting
      4.2 Lighting Energy Numeric Indicator (LENI)
    5 Metering
      5.1 General
      5.2 Load segregation
      5.3 Remote metering
    6 Calculation of lighting energy in buildings
      6.1 Installed lighting power
          6.1.1 General
          6.1.2 Luminaire
          6.1.3 Luminaire power (P[i])
          6.1.4 Parasitic powers (P[ci] and P[ei])
      6.2 Calculation methods
          6.2.1 Quick method
          6.2.2 Comprehensive method
          6.2.3 Determination of constant illuminance factor F[c]
    7 Benchmark of lighting energy requirements
    8 Lighting design and practice
    Annex A (informative) Metering of lighting circuit
    Annex B (informative) Measurement method of total power of
            luminaires and associated parasitic power
          B.1 Introduction
          B.2 Test measurement of luminaire power during normal
               operation
          B.3 Standard test conditions
          B.4 Electrical measuring instruments
          B.5 Test luminaires
          B.6 Test voltage
          B.7 Luminaire power (P[i])
          B.8 Luminaire parasitic power with lamps off (P[pi])
          B.9 Emergency lighting luminaire parasitic input power
               (P[ei])
          B.10 Lighting controls standby parasitic power (P[ci])
          B.11 Default luminaire power for existing lighting
               installations
          B.12 Default parasitic energy for existing lighting
               installations
    Annex C (informative) Determination of the daylight dependency
            factor F[D,n]
          C.1 General
          C.2 Building segmentation: Spaces benefiting from daylight
          C.3 Daylight supply
              C.3.1 Vertical fagades
              C.3.2 Rooflights
          C.4 Daylight dependent artificial lighting control, F[D,c]
          C.5 Monthly method
    Annex D (informative) Determination of occupancy dependency
            factor F[o]
          D.1 Introduction
          D.2 Detailed determination of F[o]
          D.3 Motivation for the choice of F[o] functions
    Annex E (informative) Determination of the constant illuminance
            factor F[c]
          E.1 Introduction
          E.2 Power for constant illuminance factor
          E.3 Constant illuminance factor (F[c])
    Annex F (informative) Benchmark values and lighting design criteria
    Annex G (informative) Default values
          G.1 The default values for annual operating hours relating
              to building type are given in Table G.1
    Annex H (informative) Other considerations
          H.1 Individual dimming
          H.2 Algorithmic lighting
          H.3 Light pipes
          H.4 Lighting installations with scene setting
          H.5 Daylight guidance
              H.5.1 Vertical fagades
              H.5.2 Rooflights
    Annex I (informative) List of Symbols
    Bibliography
    National Annex NA (informative) Comparison of calculation methods
                      used in Germany with those specified in this
                      European Standard

    Abstract - (Show below) - (Hide below)

    Describes the calculation methodology for the evaluation of the amount of energy used for indoor lighting inside the building and provides a numeric indicator for lighting energy requirements used for certification purposes.

    General Product Information - (Show below) - (Hide below)

    Document Type Standard
    Publisher German Institute for Standardisation (Deutsches Institut für Normung)
    Status Superseded

    Standards Referencing This Book - (Show below) - (Hide below)

    DIN V 18599-9:2016-10 ENERGY EFFICIENCY OF BUILDINGS - CALCULATION OF THE NET, FINAL AND PRIMARY ENERGY DEMAND FOR HEATING, COOLING, VENTILATION, DOMESTIC HOT WATER AND LIGHTING - PART 9: FINAL AND PRIMARY ENERGY DEMAND OF POWER GENERATION PLANTS
    DIN V 18599-6:2016-10 ENERGY EFFICIENCY OF BUILDINGS - CALCULATION OF THE NET, FINAL AND PRIMARY ENERGY DEMAND FOR HEATING, COOLING, VENTILATION, DOMESTIC HOT WATER AND LIGHTING - PART 6: FINAL ENERGY DEMAND OF VENTILATION SYSTEMS AND AIR HEATING SYSTEMS FOR RESIDENTIAL BUILDINGS
    EN 12464-1:2011 Light and lighting - Lighting of work places - Part 1: Indoor work places
    DIN V 18599-4:2016-10 ENERGY EFFICIENCY OF BUILDINGS - CALCULATION OF THE NET, FINAL AND PRIMARY ENERGY DEMAND FOR HEATING, COOLING, VENTILATION, DOMESTIC HOT WATER AND LIGHTING - PART 4: NET AND FINAL ENERGY DEMAND FOR LIGHTING
    DIN V 18599-2:2016-10 ENERGY EFFICIENCY OF BUILDINGS - CALCULATION OF THE NET, FINAL AND PRIMARY ENERGY DEMAND FOR HEATING, COOLING, VENTILATION, DOMESTIC HOT WATER AND LIGHTING - PART 2: NET ENERGY DEMAND FOR HEATING AND COOLING OF BUILDING ZONES
    DIN V 18599-3:2016-10 ENERGY EFFICIENCY OF BUILDINGS - CALCULATION OF THE NET, FINAL AND PRIMARY ENERGY DEMAND FOR HEATING, COOLING, VENTILATION, DOMESTIC HOT WATER AND LIGHTING - PART 3: NET ENERGY DEMAND FOR AIR CONDITIONING
    DIN V 18599-5:2016-10 ENERGY EFFICIENCY OF BUILDINGS - CALCULATION OF THE NET, FINAL AND PRIMARY ENERGY DEMAND FOR HEATING, COOLING, VENTILATION, DOMESTIC HOT WATER AND LIGHTING - PART 5: FINAL ENERGY DEMAND OF HEATING SYSTEMS
    DIN V 18599-7:2016-10 ENERGY EFFICIENCY OF BUILDINGS - CALCULATION OF THE NET, FINAL AND PRIMARY ENERGY DEMAND FOR HEATING, COOLING, VENTILATION, DOMESTIC HOT WATER AND LIGHTING - PART 7: FINAL ENERGY DEMAND OF AIR-HANDLING AND AIR-CONDITIONING SYSTEMS FOR NON-RESIDENTIAL BUILDINGS
    DIN V 18599-8:2016-10 ENERGY EFFICIENCY OF BUILDINGS - CALCULATION OF THE NET, FINAL AND PRIMARY ENERGY DEMAND FOR HEATING, COOLING, VENTILATION, DOMESTIC HOT WATER AND LIGHTING - PART 8: NET AND FINAL ENERGY DEMAND OF DOMESTIC HOT WATER SYSTEMS
    EN 12193:2007 Light and lighting - Sports lighting
    EN 13032-1:2004+A1:2012 Light and lighting - Measurement and presentation of photometric data of lamps and luminaires - Part 1: Measurement and file format
    DIN V 18599-1:2016-10 ENERGY EFFICIENCY OF BUILDINGS - CALCULATION OF THE NET, FINAL AND PRIMARY ENERGY DEMAND FOR HEATING, COOLING, VENTILATION, DOMESTIC HOT WATER AND LIGHTING - PART 1: GENERAL BALANCING PROCEDURES, TERMS AND DEFINITIONS, ZONING AND EVALUATION OF ENERGY SOURCES
    DIN V 18599-10:2016-10 ENERGY EFFICIENCY OF BUILDINGS - CALCULATION OF THE NET, FINAL AND PRIMARY ENERGY DEMAND FOR HEATING, COOLING, VENTILATION, DOMESTIC HOT WATER AND LIGHTING - PART 10: BOUNDARY CONDITIONS OF USE, CLIMATIC DATA
    EN 1838:2013 Lighting applications - Emergency lighting
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective