• EN 60309-2:1999/A2:2012

    Current The latest, up-to-date edition.

    PLUGS, SOCKET-OUTLETS AND COUPLERS FOR INDUSTRIAL PURPOSES - PART 2: DIMENSIONAL INTERCHANGEABILITY REQUIREMENTS FOR PIN AND CONTACT-TUBE ACCESSORIES (IEC 60309-2:1999/A2:2012)

    Available format(s): 

    Language(s): 

    Published date:  27-04-2012

    Publisher:  European Committee for Standards - Electrical

    Pure ENs are not available for sale, please purchase a suitable national adoption

    Sorry this product is not available in your region.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    Foreword
    Introduction
    1 Scope
    2 Definitions
    3 Normative references
    4 General
    5 Standard ratings
    6 Classification
    7 Marking
    8 Dimensions
    9 Protection against electric shock
    10 Provision for earthing
    11 Terminals and terminations
    12 Interlocks and retaining devices
    13 Resistance to ageing of rubber and thermoplastic
       material
    14 General construction
    15 Construction of socket-outlets
    16 Construction of plugs and connectors
    17 Construction of appliance inlets
    18 Degrees of protection
    19 Insulation resistance and dielectric strength
    20 Breaking capacity
    21 Normal operation
    22 Temperature rise
    23 Flexible cables and their connection
    24 Mechanical strength
    25 Screws, current-carrying parts and connections
    26 Creepage distances, clearances and distances through
       sealing compound
    27 Resistance to heat, fire and tracking
    28 Corrosion and resistance to rusting
    29 Conditional short-circuit current withstand test
    30 Electromagnetic compatibility
    Standards sheets
    Annex AA (informative) List of the clause numbers that require
             re-testing
    Annex ZA (normative) Normative references to international
             publications with their corresponding European
             publications
    Annex ZB (normative) Special national conditions
    Annex ZC (normative) References to Series II and/or AWG/MCM
             cables which are excluded from this standard

    Abstract - (Show below) - (Hide below)

    Pertains to plugs and socket-outlets, cable couplers with a rated operating voltage not exceeding 1000 V, 500 Hz and a rated current not exceeding 125 A, primarily intended for industrial use, either indoor or outdoors.

    General Product Information - (Show below) - (Hide below)

    Committee TC 23H
    Development Note To be read in conjunction with EN 60309-1 (12/2003) Supersedes HD 196. (03/2004) AMD 11 2004 is superseded by AMD 1 2007. (10/2014)
    Document Type Standard
    Publisher European Committee for Standards - Electrical
    Status Current

    Standards Referenced By This Book - (Show below) - (Hide below)

    I.S. EN 60092-507:2015 ELECTRICAL INSTALLATIONS IN SHIPS - PART 507: SMALL VESSELS
    I.S. HD 384-7-708:2005 ELECTRICAL INSTALLATIONS OF BUILDINGS - PART 7: REQUIREMENTS FOR SPECIAL INSTALLATIONS OR LOCATIONS - SECTION 708: ELECTRICAL INSTALLATIONS IN CARAVAN PARKS
    S.R. HD 60364-7-705:2007 LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 7-705: REQUIREMENTS FOR SPECIAL INSTALLATIONS OR LOCATIONS - AGRICULTURAL AND HORTICULTURAL PREMISES
    UNE-HD 60364-7-722:2016 Low-voltage electrical installations - Part 7-722: Requirements for special installations or locations - Supplies for electric vehicles
    HD 60364-7-708:2017 Low-voltage electrical installations - Part 7-708: Requirements for special installations or locations - Caravan parks, camping parks and similar locations
    S.R. HD 60364-7-708:2017 LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 7-708: REQUIREMENTS FOR SPECIAL INSTALLATIONS OR LOCATIONS - CARAVAN PARKS, CAMPING PARKS AND SIMILAR LOCATIONS
    BS EN 61029-1 : 2009 SAFETY OF TRANSPORTABLE MOTOR-OPERATED ELECTRIC TOOLS - PART 1: GENERAL REQUIREMENTS
    CEI EN 60092-507 : 2016 ELECTRICAL INSTALLATIONS IN SHIPS - PART 507: SMALL VESSELS
    08/30186439 DC : DRAFT SEP 2008 BS EN 15869-2 - INLAND NAVIGATION VESSELS - ELECTRICAL SHORE CONNECTION, THREE-PHASE CURRENT 400 V, UP TO 32 A, 50 HZ - PART 2: ONSHORE UNIT, SAFETY REQUIREMENTS
    BS EN 60092-507:2015 Electrical installations in ships Small vessels
    I.S. EN 12649:2008 CONCRETE COMPACTORS AND SMOOTHING MACHINES - SAFETY
    I.S. EN 60694:1999 COMMON SPECIFICATIONS FOR HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR STANDARDS
    I.S. EN 50144-1:1998 SAFETY OF HAND-HELD ELECTRIC MOTOR OPERATED TOOLS - PART 1: GENERAL REQUIREMENTS
    I.S. EN 61851-1:2011 ELECTRIC VEHICLE CONDUCTIVE CHARGING SYSTEM - PART 1: GENERAL REQUIREMENTS
    UNE-EN 62752:2017 In-cable control and protection device for mode 2 charging of electric road vehicles (IC-CPD)
    S.R. HD 60364-7-709:2009 LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 7-709: REQUIREMENTS FOR SPECIAL INSTALLATIONS OR LOCATIONS - MARINAS AND SIMILAR LOCATIONS
    I.S. HD 60364-7-705:2007 LOW-VOLTAGE ELECTRICAL INSTALLATIONS - - PART 7-705: REQUIREMENTS FOR SPECIAL INSTALLATIONS OR LOCATIONS - AGRICULTURAL AND HORTICULTURAL PREMISES (IEC 60364-7-705:2006 (MOD))
    EN 60335-1:2012/A13:2017 HOUSEHOLD AND SIMILAR ELECTRICAL APPLIANCES - SAFETY - PART 1: GENERAL REQUIREMENTS (IEC 60335-1:2010, MODIFIED)
    BS EN 13718-1:2014 Medical vehicles and their equipment. Air ambulances Requirements for medical devices used in air ambulances
    EN 60694:1996/A2:2001 COMMON SPECIFICATIONS FOR HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR STANDARDS
    HD 384.7.708 : 2005 ELECTRICAL INSTALLATIONS OF BUILDINGS - PART 7: REQUIREMENTS FOR SPECIAL INSTALLATIONS OR LOCATIONS - SECTION 708: ELECTRICAL INSTALLATIONS IN CARAVAN PARKS
    HD 60364-7-717:2010/AC:2014 LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 7-717: REQUIREMENTS FOR SPECIAL INSTALLATIONS OR LOCATIONS - MOBILE OR TRANSPORTABLE UNITS
    EN 61851-1:2011 Electric vehicle conductive charging system - Part 1: General requirements
    EN 60439-4:2004 Low-voltage switchgear and controlgear assemblies - Part 4: Particular requirements for assemblies for construction sites (ACS)
    EN 12649:2008+A1:2011 Concrete compactors and smoothing machines - Safety
    08/30186443 DC : DRAFT SEP 2008 BS EN 15869-3 - INLAND NAVIGATION VESSELS - ELECTRICAL SHORE CONNECTION, THREE-PHASE CURRENT 400 V, UP TO 32 A, 50 HZ - PART 3: ON-BOARD UNIT, SAFETY REQUIREMENTS
    NF EN 15869-2 : 2010 INLAND NAVIGATION VESSELS - ELECTRICAL SHORE CONNECTION, THREE PHASE CURRENT 400 V, UP TO 63 A, 50 HZ - PART 2: ONSHORE UNIT, SAFETY REQUIREMENTS
    BS EN 50091-1-2:1999 General and safety requirements for UPS used in restricted access locationsSpecification for uninterruptible power systems (UPS)
    CEI EN 61316 : 2000 INDUSTRIAL CABLE REELS
    BS EN 13976-1:2011 Rescue systems. Transportation of incubators Interface conditions
    13/30276231 DC : 0 BS EN 13718-1 - MEDICAL VEHICLES AND THEIR EQUIPMENT - AIR AMBULANCES - PART 1: REQUIREMENTS FOR MEDICAL DEVICES USED IN AIR AMBULANCES
    HD 60364-7-704:2018 Low voltage electrical installations - Part 7-704: Requirements for special installations or locations - Construction and demolition site installations
    BS EN 61316:2000 Industrial cable reels
    I.S. HD 384-7-754:2005 ELECTRICAL INSTALLATIONS OF BUILDINGS - PART 7: REQUIREMENTS FOR SPECIAL INSTALLATIONS OR LOCATIONS - SECTION 754: ELECTRICAL INSTALLATIONS IN CARAVANS AND MOTOR-CARAVANS
    I.S. EN 60335-1:2012 HOUSEHOLD AND SIMILAR ELECTRICAL APPLIANCES - SAFETY - PART 1: GENERAL REQUIREMENTS
    BS EN 50144-1:1999 Safety of hand-held electric motor operated tools General requirements
    S.R. HD 60364-7-730:2015 LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 7-730: REQUIREMENTS FOR SPECIAL INSTALLATIONS OR LOCATIONS - ONSHORE UNITS OF ELECTRICAL SHORE CONNECTIONS FOR INLAND NAVIGATION VESSELS
    CEI R069-001 : 2004 AC CONNECTION DEVICES FOR ELECTRIC VEHICLE CONDUCTIVE CHARGING
    I.S. HD 60364-7-721:2009 LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 7-721: REQUIREMENTS FOR SPECIAL INSTALLATIONS OR LOCATIONS - ELECTRICAL INSTALLATIONS IN CARAVANS AND MOTOR CARAVANS
    DIN EN 15869-3:2010-06 INLAND NAVIGATION VESSELS - ELECTRICAL SHORE CONNECTION, THREE PHASE CURRENT 400 V, UP TO 63 A, 50 HZ - PART 3: ON-BOARD UNIT, SAFETY REQUIREMENTS
    VDE 0623-100 : 2000-09 INDUSTRIAL CABLE REELS
    EN 13976-1:2011 Rescue systems - Transportation of incubators - Part 1: Interface conditions
    UNE-EN 15869-2:2011 Inland navigation vessels - Electrical shore connection, three phase current 400 V, up to 63 A, 50 Hz - Part 2: Onshore unit, safety requirements
    DIN EN 15869-2:2010-06 INLAND NAVIGATION VESSELS - ELECTRICAL SHORE CONNECTION, THREE PHASE CURRENT 400 V, UP TO 63 A, 50 HZ - PART 2: ONSHORE UNIT, SAFETY REQUIREMENTS
    DIN EN 61316 : 2000-09 INDUSTRIAL CABLE REELS
    UNI EN 13718-1 : 2014 MEDICAL VEHICLES AND THEIR EQUIPMENT - AIR AMBULANCES - PART 1: REQUIREMENTS FOR MEDICAL DEVICES USED IN AIR AMBULANCES
    VDE 0129-507 : 2001 ELECTRICAL INSTALLATIONS IN SHIPS - PART 507: PLEASURE CRAFT (IEC 60092-507:2000)
    BS EN 50250 : 2002 CONVERSION ADAPTORS FOR INDUSTRIAL USE
    HD 60364-7-709:2009/A11:2017 LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 7-709: REQUIREMENTS FOR SPECIAL INSTALLATIONS OR LOCATIONS - MARINAS AND SIMILAR LOCATIONS
    09/30205924 DC : 0 BS EN 13976-1 - RESCUE SYSTEMS - TRANSPORTATION OF INCUBATORS - PART 1: INTERFACE CONDITIONS
    NF EN 61029-1 : 2009 AMD 11 2011 SAFETY OF TRANSPORTABLE MOTOR-OPERATED ELECTRIC TOOLS - PART 1: GENERAL REQUIREMENTS
    HD 60364-7-705:2007/A12:2017 LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 7-705: REQUIREMENTS FOR SPECIAL INSTALLATIONS OR LOCATIONS - AGRICULTURAL AND HORTICULTURAL PREMISES
    I.S. EN 50091-1-2:2003
    I.S. EN 62752:2016&AC:2019-03 IN-CABLE CONTROL AND PROTECTION DEVICE FOR MODE 2 CHARGING OF ELECTRIC ROAD VEHICLES (IC-CPD)
    S.R. HD 60364-5-551:2010 LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 5-55: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - OTHER EQUIPMENT - CLAUSE 551: LOW-VOLTAGE GENERATING SETS
    BS EN 60335-1 : 2012 HOUSEHOLD AND SIMILAR ELECTRICAL APPLIANCES - SAFETY - PART 1: GENERAL REQUIREMENTS (IEC 60335-1:2010, MODIFIED)
    I.S. HD 60364-7-704:2007 LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 7-704: REQUIREMENTS FOR SPECIAL INSTALLATIONS OR LOCATIONS - CONSTRUCTION AND DEMOLITION SITE INSTALLATIONS
    BS EN 15869-3:2010 Inland navigation vessels. Electrical shore connection, three phase current 400 V, up to 63 A, 50 Hz On-board unit, safety requirements
    UNE-EN 13976-1:2011 Rescue systems - Transportation of incubators - Part 1: Interface conditions
    I.S. HD 60364-7-717:2010 LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 7-717: REQUIREMENTS FOR SPECIAL INSTALLATIONS OR LOCATIONS - MOBILE OR TRANSPORTABLE UNITS
    S.R. HD 60364-7-722:2016 LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 7-722: REQUIREMENTS FOR SPECIAL INSTALLATIONS OR LOCATIONS - SUPPLIES FOR ELECTRIC VEHICLES
    DIN EN 12649:2011-09 Concrete compactors and smoothing machines - Safety
    DIN EN 13718-1:2014-12 MEDICAL VEHICLES AND THEIR EQUIPMENT - AIR AMBULANCES - PART 1: REQUIREMENTS FOR MEDICAL DEVICES USED IN AIR AMBULANCES
    BS EN 12649 : 2008 CONCRETE COMPACTORS AND SMOOTHING MACHINES - SAFETY
    UNI EN 12649 : 2011 CONCRETE COMPACTORS AND SMOOTHING MACHINES - SAFETY
    UNI EN 15869-2 : 2010 INLAND NAVIGATION VESSELS - ELECTRICAL SHORE CONNECTION, THREE-PHASE CURRENT 400 V, UP TO 63 A, 50 HZ - PART 2: ONSHORE UNIT, SAFETY REQUIREMENTS
    I.S. HD 60364-7-708:2009 LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 7-708: REQUIREMENTS FOR SPECIAL INSTALLATIONS OR LOCATIONS - CARAVAN PARKS, CAMPING PARKS AND SIMILAR LOCATIONS
    I.S. EN 15869-3:2010 INLAND NAVIGATION VESSELS - ELECTRICAL SHORE CONNECTION, THREE PHASE CURRENT 400 V, UP TO 63 A, 50 HZ - PART 3: ON-BOARD UNIT, SAFETY REQUIREMENTS
    96/211090 DC : 0 CLC/TC 61F(SECRETARIAT)237 - COMMON MODIFICATIONS TO IEC 61029-2-6 FIRST EDITION) - PARTICULAR REQUIREMENTS FOR DIAMOND DRILLS WITH WATER SUPPLY
    I.S. EN 50250:2002 CONVERSION ADAPTERS FOR INDUSTRIAL USE
    I.S. EN 15869-2:2010 INLAND NAVIGATION VESSELS - ELECTRICAL SHORE CONNECTION, THREE PHASE CURRENT 400 V, UP TO 63 A, 50 HZ - PART 2: ONSHORE UNIT, SAFETY REQUIREMENTS
    I.S. EN 60439-4:2004 LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR ASSEMBLIES - PART 4: PARTICULAR REQUIREMENTS FOR ASSEMBLIES FOR CONSTRUCTION SITES (ACS)
    UNI EN 13976-1 : 2011 RESCUE SYSTEMS - TRANSPORTATION OF INCUBATORS - PART 1: INTERFACE CONDITIONS
    I.S. HD 60364-7-740:2006 ELECTRICAL INSTALLATIONS OF BUILDINGS - PART 7-740: REQUIREMENTS FOR SPECIAL INSTALLATIONS OR LOCATIONS - TEMPORARY ELECTRICAL INSTALLATIONS FOR STRUCTURES, AMUSEMENT DEVICES AND BOOTHS AT FAIRGROUNDS, AMUSEMENT PARKS AND CIRCUSES
    BS EN 15869-2:2010 Inland navigation vessels. Electrical shore connection, three phase current 400 V, up to 63 A, 50 Hz Onshore unit, safety requirements
    BS EN 61851-1:2011 Electric vehicle conductive charging system General requirements
    BS EN 60439-4:2004 Low-voltage switchgear and controlgear assemblies Particular requirements for assemblies for construction sites (ACS)
    UNE-EN 12649:2009 Concrete compactors and smoothing machines - Safety
    EN 62752:2016 In-cable control and protection device for mode 2 charging of electric road vehicles (IC-CPD)
    EN 13718-1:2014 Medical vehicles and their equipment - Air ambulances - Part 1: Requirements for medical devices used in air ambulances
    I.S. EN 13718-1:2014 MEDICAL VEHICLES AND THEIR EQUIPMENT - AIR AMBULANCES - PART 1: REQUIREMENTS FOR MEDICAL DEVICES USED IN AIR AMBULANCES
    EN 60092-507:2015/AC:2015 ELECTRICAL INSTALLATIONS IN SHIPS - PART 507: SMALL VESSELS
    UNE-EN 60335-1:2012 Household and similar electrical appliances - Safety - Part 1: General requirements
    UNE-HD 60364-7-721:2011 Low-voltage electrical installations - Part 7-721: Requirements for special installations or locations - Electrical installations in caravans and motor caravans
    DIN EN 13976-1 E : 2011 RESCUE SYSTEMS - TRANSPORTATION OF INCUBATORS - PART 1: INTERFACE CONDITIONS
    EN 15869-2:2010 Inland navigation vessels - Electrical shore connection, three phase current 400 V, up to 63 A, 50 Hz - Part 2: Onshore unit, safety requirements
    EN 15869-3:2010 Inland navigation vessels - Electrical shore connection, three phase current 400 V, up to 63 A, 50 Hz - Part 3: On-board unit, safety requirements
    NF EN 61316 : 2000 INDUSTRIAL CABLE REELS
    96/211091 DC : DRAFT AUG 1996 CLC/TC 61F(SECRETARIAT)238 - COMMON MODIFICATIONS TO IEC 61029-2-7 (FIRST EDITION) - PARTICULAR REQUIREMENTS FOR DIAMOND SAWS WITH WATER SUPPLY
    UNE-HD 60364-7-709:2011 Low-voltage electrical installations -- Part 7-709: Requirements for special installations or locations - Marinas and similar locations
    CEI EN 62752 : 1ED 2017 IN-CABLE CONTROL AND PROTECTION DEVICE FOR MODE 2 CHARGING OF ELECTRIC ROAD VEHICLES (IC-CPD)
    BS EN 60694:1997 Common specifications for high-voltage switchgear and controlgear standards
    HD 60364-7-721:2009/corrigendum:2010 LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 7-721: REQUIREMENTS FOR SPECIAL INSTALLATIONS OR LOCATIONS - ELECTRICAL INSTALLATIONS IN CARAVANS AND MOTOR CARAVANS
    NF EN 12649 : 2008 + A1 2011 CONCRETE COMPACTORS AND SMOOTHING MACHINES - SAFETY
    UNE-EN 15869-3:2011 Inland navigation vessels - Electrical shore connection, three phase current 400 V, up to 63 A, 50 Hz - Part 3: On-board unit, safety requirements
    NF EN 15869-3 : 2010 INLAND NAVIGATION VESSELS - ELECTRICAL SHORE CONNECTION THREE PHASE CURRENT 400 V, UP TO 63 A, 50 HZ - PART 3: ON-BOARD UNIT, SAFETY REQUIREMENTS
    HD 60364-7-722:2016 Low-voltage electrical installations - Part 7-722: Requirements for special installations or locations - Supplies for electric vehicles
    I.S. HD 60364-7-709:2009 LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 7-709: REQUIREMENTS FOR SPECIAL INSTALLATIONS OR LOCATIONS - MARINAS AND SIMILAR LOCATIONS (IEC 60364-7-709:2007 (MOD))
    UNE-HD 60364-7-708:2018 Low-voltage electrical installations - Part 7-708: Requirements for special installations or locations - Caravan parks, camping parks and similar locations
    S.R. HD 60364-7-740:2006 ELECTRICAL INSTALLATIONS OF BUILDINGS - PART 7-740: REQUIREMENTS FOR SPECIAL INSTALLATIONS OR LOCATIONS - TEMPORARY ELECTRICAL INSTALLATIONS FOR STRUCTURES, AMUSEMENT DEVICES AND BOOTHS AT FAIRGROUNDS, AMUSEMENT PARKS AND CIRCUSES
    I.S. EN 61029-1:2009 SAFETY OF TRANSPORTABLE MOTOR-OPERATED ELECTRIC TOOLS - PART 1: GENERAL REQUIREMENTS
    S.R. HD 60364-7-704:2007 LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 7-704: REQUIREMENTS FOR SPECIAL INSTALLATIONS OR LOCATIONS - CONSTRUCTION AND DEMOLITION SITE INSTALLATIONS
    UNI EN 15869-3 : 2010 INLAND NAVIGATION VESSELS - ELECTRICAL SHORE CONNECTION, THREE-PHASE CURRENT 400 V, UP TO 63 A, 50 HZ - PART 3: ON-BOARD UNIT, SAFETY REQUIREMENTS
    DIN EN 13976-1:2016-03 (Draft) RESCUE SYSTEMS - TRANSPORTATION OF INCUBATORS - PART 1: INTERFACE CONDITIONS
    I.S. EN 13976-1:2011 RESCUE SYSTEMS - TRANSPORTATION OF INCUBATORS - PART 1: INTERFACE CONDITIONS
    UNE-HD 60364-7-730:2016 Low-voltage electrical installations - Part 7-730: Requirements for special installations or locations - Onshore units of electrical shore connections for inland navigation vessels
    EN 50250 : 2002 AMD 1 2015 CONVERSION ADAPTERS FOR INDUSTRIAL USE
    EN 61029-1:2009/A11:2010 SAFETY OF TRANSPORTABLE MOTOR-OPERATED ELECTRIC TOOLS - PART 1: GENERAL REQUIREMENTS
    DIN EN 13976-1:2011-08 RESCUE SYSTEMS - TRANSPORTATION OF INCUBATORS - PART 1: INTERFACE CONDITIONS
    HD 60364-7-740:2006/A11:2017 ELECTRICAL INSTALLATIONS OF BUILDINGS - PART 7-740: REQUIREMENTS FOR SPECIAL INSTALLATIONS OR LOCATIONS - TEMPORARY ELECTRICAL INSTALLATIONS FOR STRUCTURES, AMUSEMENT DEVICES AND BOOTHS AT FAIRGROUNDS, AMUSEMENT PARKS AND CIRCUSES
    HD 60364-7-730:2015 Low-voltage electrical installations - Part 7-730: Requirements for special installations or locations - Onshore units of electrical shore connections for inland navigation vessels
    HD 60364-5-551:2010/A11:2016 LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 5-55: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - OTHER EQUIPMENT - CLAUSE 551: LOW-VOLTAGE GENERATING SETS
    EN 50091-1-2 : 98 COR 1 99
    EN 50144-1 : 98 COR 2005 SAFETY OF HAND-HELD ELECTRIC MOTOR OPERATED TOOLS - PART 1: GENERAL REQUIREMENTS
    HD 384.7.754 : 2005 ELECTRICAL INSTALLATIONS OF BUILDINGS - PART 7: REQUIREMENTS FOR SPECIAL INSTALLATIONS OR LOCATIONS - SECTION 754: ELECTRICAL INSTALLATIONS IN CARAVANS AND MOTOR-CARAVANS
    UNE-HD 60364-7-717:2013 Low-voltage electrical installations -- Part 7-717: Requirements for special installations or locations - Mobile or transportable units
    UNE-HD 60364-5-551:2013 Low-voltage electrical installations -- Part 5-55: Selection and erection of electrical equipment - Other equipment -- Clause 551: Low-voltage generating sets

    Standards Referencing This Book - (Show below) - (Hide below)

    IEC 60364-4-41:2005+AMD1:2017 CSV Low voltage electrical installations - Part 4-41: Protection for safety - Protection against electric shock
    HD 60364-4-41:2017/A11:2017 LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 4-41: PROTECTION FOR SAFETY - PROTECTION AGAINST ELECTRIC SHOCK
    EN 60617-2 : 1996 GRAPHICAL SYMBOLS FOR DIAGRAMS - SYMBOL ELEMENTS. QUALIFYING SYMBOLS AND OTHER SYMBOLS HAVING GENERAL APPLICATION
    IEC 60617-2:1996 Graphical symbols for diagrams - Partie 2: Symbol elements, qualifying symbols and other symbols having general application
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective